Superior Life PQL-84248 User manual

Type
User manual

Superior Life PQL-84248 is a powerful LED stadium light designed for illuminating large outdoor areas. With its high-efficiency LEDs, it delivers bright and uniform light distribution, making it ideal for sports fields, parking lots, and other large-scale applications. The PQL-84248 is built to withstand harsh weather conditions and features adjustable mounting options for easy installation. It also offers dimming capabilities for added energy savings and customization of light output.

Superior Life PQL-84248 is a powerful LED stadium light designed for illuminating large outdoor areas. With its high-efficiency LEDs, it delivers bright and uniform light distribution, making it ideal for sports fields, parking lots, and other large-scale applications. The PQL-84248 is built to withstand harsh weather conditions and features adjustable mounting options for easy installation. It also offers dimming capabilities for added energy savings and customization of light output.

LED STADIUM LIGHTS V2
INSTALL INSTRUCTIONS
PREMIUM QUALITY LIGHTING® • www.PQLighting.com
© P.Q.L., Inc. • 2285 Ward Avenue • Simi Valley, CA 93065 • 800-323-8107
Specifications subject to change without notice. Photos and line
drawings may not be to scale and are for general reference only.
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the luminaire.
GENERAL: ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODE (N.E.C.) STANDARDS. IF YOU ARE
UNFAMILIAR WITH PROPER ELECTRICAL WIRING CONNECTIONS OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN.
WARNING - Risk of fire or electric shock. Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation; contact
a qualified electrician.
WARNING - Risk of fire or electric shock. Install luminaires that have the construction features and dimensions shown in the photographs and/or drawings
and where the voltage input rating of the does not exceed the voltage input rating of the luminaire.
WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during installation.
Risk of Electric Shock: Disconnect power or circuit breaker before installing or servicing.
Before installation, please check if the local voltage range corresponds with the working voltage of the fixture.
If the fixture is damaged, it should be replaced by the supplier, a service agent or a qualified person.
Do not use where exposed to flame, electric shock, or high vibration.
300W / 400W / 500W / 600W
STEP 1 - Attach glare shield to the luminaire body by using the
M5x12mm screws to lock the shield in place.
STEP 2 - MOUNTING LUMINAIRE
1. Place fixture on the mounting surface.
2. Insert M20 and M10 bolts into bracket. Tighten the bolts hand tight
so luminaire is secured to the mounting surface but still allow
adjustment. Do not fully torque down until desired position is set.
3. Adjust bracket and fixture vertically, and for Install Method 1
horizontally.
4. Fully tighten all bolts to secure fixture.
General Wiring Diagram on Page 2.
MOUNTING DIAGRAM
Glare Shield
Heat Sink
M5 x 12mm Hex Screw
!WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
110°
240° 240°
M20 Bolt
M10 Bolt
M20 Bolt
7.9
2.3”
0.83”
1.4”  0.83”
 2.3” R0.2”
1.2”
OPTIONAL U-BRACKET WITH SLIP FITTER FOR
300W / 400W / 500W / 600W (Item# 84080, sold separately)
MOUNTING LUMINAIRE
1. Secure fixture in U-Bracket.
2. Place slip fitter on light pole. Tighten the bolts hand tight
so luminaire is secure but allows adjustment.
3. Adjust fixture to desired angle.
4. Fully tighten all bolts to secure fixture.
General Wiring Diagram on Page 2.
2 ” 90° - 27
(180°)
INSTALL METHOD 1 INSTALL METHOD 2
LED STADIUM LIGHTS V2
INSTALL INSTRUCTIONS
PREMIUM QUALITY LIGHTING® • www.PQLighting.com
© P.Q.L., Inc. • 2285 Ward Avenue • Simi Valley, CA 93065 • 800-323-8107
Specifications subject to change without notice. Photos and line
drawings may not be to scale and are for general reference only.
Glare Shield
Heat Sink
M5 x 12mm Hex Screw
110°
240°
M20 Bolt
M10 Bolt
M20 Bolt
240°
750W / 1250W*
STEP 1 - Attach glare shield to the luminaire body by using the
M5x12mm screws to lock the shield in place.
STEP 2 - MOUNTING LUMINAIRE
1. Place fixture on the mounting surface.
2. Insert M20 and M10 bolts into bracket. Tighten the bolts hand
tight so luminaire is secured to the mounting surface but
still allow adjustment. Do not fully torque down until desired
position is set.
3. Adjust bracket and fixture vertically, and for Install Method 1
horizontally.
4. Fully tighten all bolts to secure fixture.
INSTALL METHOD 1 INSTALL METHOD 2
!WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.
MOUNTING DIAGRAM
7.9
2.3”
0.83”
1.4”  0.83”
 2.3” R0.2”
1.2”
Black --L--
White --N--
Green
Purple --DIM(+)--
Gray -- DIM(-)--
L L
N N
GND GND
0-10V
GENERAL WIRING DIAGRAM
*Note: For non-dimming applications, cap the purple
and gray dimming wires separately. Failure to do so may
cause malfunctioning and void warranty.
Label
*Note: The 1250W Stadium Light uses an external driver box.
The driver box should be mounted within 85’ of the fixture to
prevent voltage loss.
  • Page 1 1
  • Page 2 2

Superior Life PQL-84248 User manual

Type
User manual

Superior Life PQL-84248 is a powerful LED stadium light designed for illuminating large outdoor areas. With its high-efficiency LEDs, it delivers bright and uniform light distribution, making it ideal for sports fields, parking lots, and other large-scale applications. The PQL-84248 is built to withstand harsh weather conditions and features adjustable mounting options for easy installation. It also offers dimming capabilities for added energy savings and customization of light output.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI