NOVALUX 55394 is an LED emergency battery backup system designed for use with grounded, UL Listed, Damp location rated fixtures with a grounded case. It provides emergency lighting in the event of a power outage, with a battery that charges in 24 hours and lasts through a power outage. The test switch allows for manual testing of the emergency function, and the LED indicator shows the charging status. Installation requires a qualified electrician and should be done in accordance with the National Electrical Code and local regulations.

NOVALUX 55394 is an LED emergency battery backup system designed for use with grounded, UL Listed, Damp location rated fixtures with a grounded case. It provides emergency lighting in the event of a power outage, with a battery that charges in 24 hours and lasts through a power outage. The test switch allows for manual testing of the emergency function, and the LED indicator shows the charging status. Installation requires a qualified electrician and should be done in accordance with the National Electrical Code and local regulations.

LED EM. BATTERY BACKUP • 55394
INSTALL INSTRUCTIONS
PREMIUM QUALITY LIGHTING® • www.PQLighting.com
© P.Q.L., Inc. • 2285 Ward Avenue • Simi Valley, CA 93065 • 800-323-8107
Specifications subject to change without notice. Photos and line
drawings may not be to scale and are for general reference only.
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the emergency battery backup.
WARNING - Risk of fire or electric shock. LED emergency backup installation requires knowledge of luminaire electrical systems. If not qualified, do not
attempt installation. Contact a qualified electrician.
CAUTION: RISK OF INJURY
Do not use outdoors.
Do not mount near gas or electric heaters.
Equipment should not be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel.
The use of accessory equipment is not recommended and may cause an unsafe condition.
Do not use this equipment for other than intended use.
For use with grounded, UL Listed, Damp location rated fixture with a grounded case.
The equipment is intended for ordinary locations and for permanent installation into one or more Listed emergency luminaires.
Install in accordance with the National Electrical Code and local regulations.
!WARNING - TURN OFF POWER SUPPLY FROM MAIN CIRCUIT BREAKER BEFORE INSTALLING OR SERVICING.
Fig. A
2. Take the wire out of the driver box.
Use needle-nose pliers to clamp the plugs
and take out from the driver box. (Fig. A)
Open the outlet plate and remove the wire
from the knock-out. (Fig. B)
3. Cut o the plug with the four wires.
1. Open knock-outs with screw driver.
Fig. B
INSTALLATION INSTRUCTIONS - Installation eects the whole fixture.
Only for use with fixtures less than 300W.
Review all instructions before installation and usage.
This item could be used in an enclosed fixture or installed in the open area of the fixture.
Keep away from flammable materials and in a place with good heat dissipation.
Charge the battery consistently for more than 24 hours before usage to activate all battery cells of discharging/charging duration.
LED EM. BATTERY BACKUP • 55394
INSTALL INSTRUCTIONS
PREMIUM QUALITY LIGHTING® • www.PQLighting.com
© P.Q.L., Inc. • 2285 Ward Avenue • Simi Valley, CA 93065 • 800-323-8107
Specifications subject to change without notice. Photos and line
drawings may not be to scale and are for general reference only.
TEST SWITCH
Emergency battery backup will go into emergency mode if test switch is
pressed when main supply is on, it will remain in charging mode if test
switch is not pressed.
In emergency mode, press the test switch for 3 seconds to turn o the
current emergency state.
LED INDICATOR
Solid Red Light: charging mode or fully charged.
Red Light O: main power o or in discharge mode.
MAINTENANCE
Turn o the main power every 3 months, to let the battery operate a charging/discharging cycle. This will help extend the life of the battery.
Check the emergency function with the push test button.
8. Installation complete.
GENERAL WIRING DIAGRAM
7. Insert conduit hose into the knock-out and connect wires.
Then install covers on wire boxes.
6. Install emergency battery - refer to general wiring diagram.
5. Open knock-outs with a screwdriver.4. Install test switch before installing wire boxes. Then install
mounting bracket. (Item#: 55395 or 55393 - Mounting Bracket
and Wire Boxes sold separately as a kit.)
Test Switch
Mounting Bracket
Wire Boxes
Red
Gray
Purple
Black
Blue
White
Red
Black
White
Brown
Emergency Battery
AC-L
AC-N
LED Driver
Black
White
White
Gray Gray
Purple
LED Array LED +
LED - (Gray)
(White
Black
Green
Blue
White
Black
Red
Black
White
Test Switch
Purple
Gray
Red
)
  • Page 1 1
  • Page 2 2

NOVALUX 55394 User manual

Category
Rechargeable batteries
Type
User manual

NOVALUX 55394 is an LED emergency battery backup system designed for use with grounded, UL Listed, Damp location rated fixtures with a grounded case. It provides emergency lighting in the event of a power outage, with a battery that charges in 24 hours and lasts through a power outage. The test switch allows for manual testing of the emergency function, and the LED indicator shows the charging status. Installation requires a qualified electrician and should be done in accordance with the National Electrical Code and local regulations.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI