echoflex ER6CD Installation guide

Type
Installation guide

The echoflex ER6CD is a Phase Adaptive Dimmer controller that provides forward or reverse phase dimming control for line voltage lighting with single channel output based on input from compatible Echoflex devices. It supports various loads such as tungsten lamps, ELV and MLV, 2-wire fluorescent ballasts, and LED drivers. The controller can be linked with up to 20 compatible Echoflex switches or sensors, allowing for wireless control and dimming of lights. It features a pre-commissioned state for easy setup and can be reset to factory default if needed.

The echoflex ER6CD is a Phase Adaptive Dimmer controller that provides forward or reverse phase dimming control for line voltage lighting with single channel output based on input from compatible Echoflex devices. It supports various loads such as tungsten lamps, ELV and MLV, 2-wire fluorescent ballasts, and LED drivers. The controller can be linked with up to 20 compatible Echoflex switches or sensors, allowing for wireless control and dimming of lights. It features a pre-commissioned state for easy setup and can be reset to factory default if needed.

Echoflex Installation Guide
Phase Adaptive Dimmer (ER6CD/ER12CD)
Corporate Headquarters Middleton, WI, USA | Phone +1 608 831 4116
Web echoflexsolutions.com | Email [email protected] | Support [email protected]
© 2021 Echoflex Solutions, Inc. Trademark and patent info: echoflexsolutions.com/ip
Echoflex intends this document to be provided in its entirety. Product information and specifications subject to change.
8189M2112 Rev A Released 2021-08
Overview
The Phase Adaptive Dimmer
controller provides forward or
reverse phase dimming control
for line voltage lighting with
single channel output based on
input from compatible Echoflex
devices.
The 1200 Watt Phase Adaptive
Dimmer (ER12CD) is available at
120 VAC or 277 VAC. The 600
Watt model (ER6CD) is available
at 120 VAC.
The dimmer provides control for
line voltage tungsten lamps,
Electronic Low Voltage (ELV) and Magnetic Low Voltage (MLV) loads (120 V
only), 2-wire fluorescent ballasts, and line voltage LED drivers.
This document covers the installation of all the Phase Adaptive Dimmer
Controller models. The Echoflex Phase Dimmer Controller Configuration
Guide is available for download at echoflexsolutions.com.
The product package includes the controller and a lock nut.
Prepare for Installation
To ensure optimal function, consider the installation environment and the
following guidelines:
High density construction materials and large metal appliances or
fixtures in the space may disrupt wireless reception.
Switches and sensors should be installed within range, 24 m (80 ft)
unobstructed view. Consider adding a repeater to extend the wireless
signal, if required.
Mount the controller to an electrical junction box or a panel in a
location and at a height where it is not subject to tampering by
unauthorized personnel.
Supplies required to install the controller (not provided):
Appropriately sized wire nuts
Small cable ties
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 2 of 12 Echoflex
IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
.
.
This product is suitable for use in dry locations where the ambient
temperatures is 0°C to 50°C (32°F to 122°F).
Do not use outdoors.
Do not mount near gas or electric heaters.
Equipment should be mounted in locations and at heights where it is
not subject to tampering by unauthorized personnel.
The use of accessory equipment not recommended by the
manufacturer may cause an unsafe condition.
Do not use this equipment for other than its intended use.
Servicing should be performed by qualified service personnel.
Pollution Degree: 2.
SAVE THESE INSTRUCTIONS
WARNING: Risk of electric shock! This device utilizes high
voltage and should only be installed by a qualified installer or
electrician. Follow all local codes for installation. Before
terminating the AC power wiring verify that the main breaker
is in the off position and follow the proper lockout/tag out
procedures per NFPA Standard 70E.
AVERTISSEMENT: Risque de décharge électrique! Cette
appareil utilise une haute tension et ne doit être installé que
par un installateur qualifié ou un électricien. Suivez tous les
codes locaux pour l'installation. Avant de raccorder le câblage
du courant alternatif, vérifiez que le disjoncteur principal est
en position d'arrêt et suivez les procédures de Consignation/
Déconsignation prescrites par la norme NFPA 70E.
WARNING: For indoor use only! Must install to an electrical
junction box or wireway.
AVERTISSEMENT: Uniquement pour usage d'intérieur! Doit
être installé sur une boîte de raccordement électrique ou un
chemin de câbles.
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 3 of 12 Echoflex
Installation
Ensure that the junction box is clean and free of obstructions and that all
wiring is installed correctly.
Install the Controller
Mount the controller directly to the exterior of the junction box or panel
either at the electrical load or before the load in the circuit.
Review these instructions completely before installing the controller.
1. Locate the circuit breaker panel and terminate power to the circuit.
2. Remove the cover plate and other hardware from the junction box to
access the wiring.
3. Mount the controller.
4. Refer to the wiring diagram on page 4 to connect the controller to line
power, neutral, and load wires. Use wire nuts on all connections and
individually cap any bare wires, except the orange antenna wire.
The dimmer is supplied with a wire harness that is specific to the input
voltage, either 120 VAC or 277 VAC.
a. Connect the striped green/yellow wire to the ground wire from
the breaker panel and the ground wire from the lighting load.
b. Connect the white wire to the incoming neutral wire from the
breaker panel and the neutral wire of the lighting load.
c. Connect the incoming hot wire (black 120 VAC, or brown
277 VAC) to the line input feed wire (hot) from the breaker panel.
d. Connect the red output wire to the lighting load.
5. Replace the electrical box cover plate.
6. Restore power to the circuit.
Note:
Follow applicable NEC and local electrical code
requirements when installing and powering the
controller.
Note:
Do not share the neutral wire with other loads. Connect
a dedicated neutral conductor to the electrical panel.
Note:
Do not mix fixture types on the controlled output. All
fixtures on the controlled circuit should be identical.
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 4 of 12 Echoflex
Wiring Diagram
Electrical Terminations
Power to the controller is connected between the White (Neutral) and the
Black or Brown Line power (120 or 277 VAC), respectively. The orange wire
is an antenna. Do not cut, cap, or connect this wire. Use only UL-approved
wire when making connections to the controller (see table below).
Controller Interface
The controller has two LEDs and two lever-type buttons located below the
label.
Power LED and Learn LED
The Power and Learn LEDs can display green, blue, or red. LED color and
combinations indicate whether the controller is providing information via
blink codes or is in an operational mode. See Blink Codes and Operations
on page 6.
Connection Color Specification
Load Red 14 AWG, 600 V
Neutral White 14 AWG, 600 V
Line Black or Brown 14 AWG, 600 V
Neutral - To other fixtures
Black - Line, 120 V or
Brown - Line, 277 V
White - Neutral
To other 120 V or 277 V fixtures
Green/Yellow Ground
ER12CD-AU
1200 W Dimmer
Dimmable
Lighting
Fixture
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 5 of 12 Echoflex
Learn Button
The [Learn] button initiates Link mode for linking compatible Echoflex
devices to the controller. See the relevant switch or sensor documentation
for information on linking. Link mode times out after 30 seconds of
inactivity.
Devices can be linked to a controller during the Echoflex pre-commissioning
process, or linked manually. Repeating the linking process for a device that
is already linked to a controller will unlink it from that controller.
Clear Button
The [Clear] button resets the controller either to its pre-commissioned state
or to its factory default state.
To reset to pre-commissioned state:
1. Press the [Clear] button until the red Power and green Learn LEDs are
both solid ON.
2. Release the [Clear] button. The red Power LED blink code indicates the
type and count of devices linked at pre-commissioning.
To reset to factory default state:
1. Press and hold the [Clear] button until the red Power and green Learn
LEDs start blinking (about 15 seconds).
2. Release the [Clear] button. The Power LED displays solid red to indicate
factory default state. All links are removed.
Test the Controller
Echoflex provides the controller in either a pre-commissioned state or a
factory default state.
Pre-commissioned devices are linked, configured, and labeled
according to customer specifications. When powered up, the red
Power LED repeats a blink code to indicate the type and number of
devices currently linked to the controller. See Blink Codes and
Operations on page 6. To test the dimmer, press the [Learn] button
or use a linked switch.
In factory default state, when powered up, the Power LED displays
solid red to indicate the controller has no linked devices. To test the
dimmer, press the [Learn] button or link a switch. See the relevant
switch documentation.
A maximum of 20 switches or sensors can be linked to one controller.
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 6 of 12 Echoflex
Blink Codes and Operations
The tables below describe the controller's LED blink codes and operations.
If the controller is in factory default state, the red Power LED is solid
ON.
If the controller has one or more devices linked to it, the red Power
LED repeats a blink code to indicate the type and number of linked
devices. Long blinks = type. Short blinks = count.
Blink Codes
Operations
Description Power LED (red) Learn LED
Factory default On solid Off
Switches 1 long blink followed by short
blinks that count the switches Off
Occupancy sensors 2 long blinks followed by short
blinks that count the sensors Off
Photo sensor
(maximum of 1)
3 long blinks followed by short
blink that counts the sensor Off
Gateways and
TimeClocks
4 long blinks followed by short
blinks that count the devices Off
Demand Response 5 long blinks followed by short
blinks that count the devices Off
Entry Door Switches 6 long blinks followed by short
blinks that count the switches Off
Keycard Switches 7 long blinks followed by short
blinks that count the switches Off
Activity Power LED
(red)
Learn LED
(green) Light
Link mode Blink On solid Toggle
Store link ID On 4 seconds On solid On 4 seconds
Clear link ID Off 4 seconds On solid Off 4 seconds
Factory default On solid One blink
(on power-up) On solid
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 7 of 12 Echoflex
Dimmer Settings
The interface buttons and repeating color LEDs are used to navigate the
settings menu. You can change the phase dimming mode or set the LED
drive mode to control the minimum dimming level.
Phase Dimming Mode
The controller supports three modes: Reverse, Forward, and Automatic
phase detection (default). With Automatic phase, the controller recognizes
if the load is inductive or capacitive and automatically switches to forward
phase for an inductive load or to reverse phase for a capacitive/resistive load.
To change the phase dimming mode:
1. Press and hold both the [Learn] and the [Clear] buttons until both the
Power and Learn LEDs blink blue to access the dimming menu.
2. Release both buttons. The Power LED remains ON solid blue and the
Learn LED blinks blue to indicate the current phase setting:
1 blink = Automatic phase detection (default)
2 blinks = Reverse phase dimming (for ELV, LED, incandescent, or
halogen loads)
3 blinks = Forward phase dimming (for MLV loads)
3. Press and release the [Learn] button to cycle through the blink codes
until your target setting displays.
4. Press and hold the [Clear] button until the Learn LED blinks blue to
save and exit the menu.
Note:
If the lighting load is not dimming smoothly when
controlled by the dimmer, contact technical services
before adjusting the phase dimming mode.
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 8 of 12 Echoflex
LED Drive Mode
The LED drive mode can be enabled or disabled according to the load.
Enabled (default) - the minimum dimming level is used. Enable the
setting for use with ELV, LED, MLV track lighting with LED loads, or
2-wire fluorescent.
Disabled - the minimum dimming value is 0. Disable the setting for
use with halogen or incandescent, and for MLV track lighting with
halogen or incandescent loads.
To Disable LED drive mode:
1. Press and hold both the [Learn] and the [Clear] buttons until both the
Power and Learn LEDs blink blue to access the dimming menu.
2. Press the [Clear] button once to access the drive mode menu. The
Power LED remains ON solid blue and the Learn LED blinks green to
indicate:
1 blink = Disabled
2 blinks = Enabled (default)
3. Press and release the [Learn] button to cycle through the blink codes
until 1 green blink displays (disabled).
4. Press and hold the [Clear] button until the Learn LED blinks blue to
save and exit the menu.
To
Enable
LED drive mode and adjust minimum dimming level:
1. Press and hold both the [Learn] and the [Clear] buttons until both the
Power and Learn LEDs blink blue to access the dimming menu.
2. Press the [Clear] button once to access the drive mode menu. The
Power LED remains ON solid blue and the Learn LED blinks green to
indicate:
1 blink = Disabled
2 blinks = Enabled (default)
3. Press and release the [Learn] button to cycle through the blink codes
until 2 green blinks display (enabled).
4. Press the [Clear] button once to access the levels menu. The Power LED
remains ON solid blue and the Learn LED is ON solid red.
5. Press and release the [Learn] button to increase the minimum
dimming level by 5% increments. The default dimming level is 20%.
The levels wrap around to 0% once 100% is reached.
6. Press and hold the [Clear] button until the Learn LED blinks blue to
save and exit the menu.
The dimming menu times out after 30 seconds of inactivity.
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 9 of 12 Echoflex
Compliance
For current and complete compliance information, see the Echoflex Phase
Adaptive Dimmer datasheet at echoflexsolutions.com.
FCC Compliance
Echoflex Phase Adaptive Dimmer
(For any FCC matters):
Echoflex Solutions, Inc.
3031 Pleasant View Road
Middleton, WI 53562
+1 (608) 831-4116
echoflexsolutions.com
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio
communications. Any modifications or changes to this product not expressly approved by
Electronic Theatre Controls, Inc. could void the user’s authority to operate the product. Operation
of this equipment in a residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
Contains FCC ID: SZV-STM300U
ISED Compliance
This device contains a license-exempt transmitter/receiver that complies with Innovation, Science,
and Economic Development Canada’s license-exempt RSSs. Operation is subject to the following
two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
Contains IC ID: 5713A-STM300U
Conformité ISDE
Cet appareil contient un émetteur/récepteur conforme aux CNR d'Innovation, Sciences et
Développement économique Canada (ISDE) applicables aux appareils radio exempt de licence.
Son fonctionnement est soumis aux deux conditions suivantes:
1. L'appareil ne doit pas produire d'interférences.
2. L'utilisateur de l'appareil doit accepter toute interférence, même si l'interférence est
susceptible d'en compromettre le fonctionnement.
Contient ID IC: 5713A-STM300U
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 10 of 12 Echoflex
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 11 of 12 Echoflex
Echoflex Installation Guide
Phase Adaptive Dimmer
Phase Adaptive Dimmer (ER6CD/ER12CD) Page 12 of 12 Echoflex
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

echoflex ER6CD Installation guide

Type
Installation guide

The echoflex ER6CD is a Phase Adaptive Dimmer controller that provides forward or reverse phase dimming control for line voltage lighting with single channel output based on input from compatible Echoflex devices. It supports various loads such as tungsten lamps, ELV and MLV, 2-wire fluorescent ballasts, and LED drivers. The controller can be linked with up to 20 compatible Echoflex switches or sensors, allowing for wireless control and dimming of lights. It features a pre-commissioned state for easy setup and can be reset to factory default if needed.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI