Interacoustics affinity 2.0 Additional information

Category
Measuring, testing & control
Type
Additional information

This manual is also suitable for

D-0004576-I 2017/11
Additional Information
Affinity
2.0
/ Equinox
2.0
Hearing Aid Analyzer
Table of Contents
1 AC440 .............................................................................................................................. 1
1.1 About AC440 Module ..................................................................................................... 1
1.2 Launching AC440 with Databases ................................................................................. 2
1.2.1 Launching from OtoAccess ...................................................................................... 2
1.2.2 Launching AC440 from Noah....................................................................................... 3
1.2.3 Using the Tone Screen................................................................................................ 4
1.3 The Speech Screen Elements ...................................................................................... 10
1.3.1 Speech Audiometry in Graph Mode............................................................................ 13
1.3.1.1 Dual Speech Graphs................................................................................... 14
1.3.1.2 50% Discrimination Line .............................................................................. 14
1.3.1.3 Bönninghaus & Röser calculation ................................................................ 15
1.3.2 Speech Audiometry in Table Mode .............................................................. 16
1.3.2.1 The SRT table ............................................................................................ 16
1.3.2.2 The WR Table ............................................................................................ 17
1.4 Binaural speech........................................................................................................... 18
1.5 Full 2(4) channel Speech in noise................................................................................ 19
1.6 Counselling Tab .......................................................................................................... 21
1.6.1 Sound Studio............................................................................................................ 21
1.7 Clinical Application of the AC440 Tests ...................................................................... 22
Air Conduction Audiometry .................................................................................................... 22
1.7.1 High Frequency Audiometry ...................................................................................... 24
1.7.2 Multi Frequency Audiometry ...................................................................................... 25
1.7.3 Bone Conduction Audiometry .................................................................................... 26
1.7.4 Masking 27
1.7.5 Speech Audiometry................................................................................................... 28
1.7.5.1 Speech Reception Threshold (SRT) in Table Mode....................................... 30
1.7.5.2 Word Recognition (WR) in table mode ......................................................... 31
1.7.5.3 Speech Testing with a Microphone .............................................................. 32
1.7.5.4 Speech Testing with an external CD Player .................................................. 33
1.7.5.5 Speech testing with Wave Files ................................................................... 34
1.7.6 Masking Level Difference (MLD) ................................................................................ 36
1.7.7 Master Hearing Aid (MHA)......................................................................................... 38
1.7.8 Hearing Loss Simulation (HLS) .................................................................................. 40
1.7.9 Short Increment Sensitivity Index ............................................................................... 42
1.7.10 Weber .................................................................................................................. 44
1.7.11 Knaster .................................................................................................................. 45
1.7.12 ABLB/Fowler ............................................................................................................ 47
1.7.13 Stenger Test............................................................................................................. 48
1.7.14 TEN Test .................................................................................................................. 50
1.7.15 QuickSIN .................................................................................................................. 51
1.7.16 Tone Decay.............................................................................................................. 53
1.7.17 ANL Test
18
............................................................................................................... 56
1.7.18 SIQ Test .................................................................................................................. 61
1.7.19 SIN Test .................................................................................................................. 63
1.8 Working with Individual Setups (Test Protocols)......................................................... 65
1.8.1 Selecting a Test Protocol:.......................................................................................... 65
1.8.2 Creating new Protocols ............................................................................................. 66
1.8.2.1 Common Setup .......................................................................................... 66
1.8.2.2 Tone Testing Setup..................................................................................... 68
1.8.2.3 Speech Testing Setup ................................................................................. 80
1.8.2.4 MLD testing Setup ..................................................................................... 88
1.8.2.5 MHA Counselling Setup .............................................................................. 90
1.8.2.6 Knaster Testing Setup................................................................................. 92
1.8.2.7 HLS Counselling Setup ............................................................................... 94
1.8.2.8 SISI Testing Setup ...................................................................................... 97
1.8.2.9 Weber Testing Setup .................................................................................. 98
1.8.2.10 QuickSIN Setup .......................................................................................... 99
1.8.2.11 QuickSIN Additional Features Setup ...........................................................101
1.8.2.12 ABLB/Fowler and Stenger Setup ................................................................103
1.8.2.13 TEN test Setup ..........................................................................................103
1.8.2.1 ANL Test Setup .........................................................................................104
1.8.2.2 SIQ Test Setup ..........................................................................................106
1.8.2.3 SIN Test Setup ..........................................................................................108
1.8.3 Finishing the Test Protocol .......................................................................................110
1.8.4 Changing a Test Protocol Permanently .....................................................................110
1.8.5 Changing a Test Protocol Temporarily ......................................................................111
1.8.6 Importing and Exporting Test Protocols .....................................................................112
1.8.6.1 Importing a Test Protocol: ..........................................................................112
1.8.6.2 Exporting a Test Protocol: ..........................................................................113
1.9 General Setup .............................................................................................................114
1.9.1 Symbol editor ..........................................................................................................115
1.9.2 Noah database settings............................................................................................116
1.9.3 Tone and speech settings ........................................................................................116
1.10 General Suite Settings and Examiner .........................................................................117
1.10.1 Startup 117
1.10.2 Examiner settings ....................................................................................................117
1.10.3 Language ................................................................................................................118
1.10.4 PDF Print ................................................................................................................119
1.11 Password protection ..................................................................................................120
1.12 The AC440 Menu Items ...............................................................................................121
1.13 PC Shortcut Manager .................................................................................................123
1.14 Standalone Database Settings....................................................................................124
1.15 FAQ ............................................................................................................................125
1.16 Appendix 1 .................................................................................................................127
1.16.1 Importing Wave Files Speech from Hard Drive (ISF440) ..........................................127
1.17 Appendix 2 .................................................................................................................132
1.17.1 Audiometer Implementation of the TEN(HL) Test for Diagnosing Cochlear
Dead Regions .........................................................................................................132
1.18 Appendix 3 .................................................................................................................139
1.18.1 Masking Help/Automasking Quick Guide ...................................................................139
2 REM440 ........................................................................................................................144
2.1 Quick Guide................................................................................................................144
2.2 About REM440 ............................................................................................................146
2.3 REM440 Tests .............................................................................................................146
2.4 Launching REM440 with Databases ...........................................................................147
2.4.1 Launching REM440 from Noah4: ..............................................................................147
2.4.2 Launching REM440 from OtoAccess: ....................................................................147
2.5 The REM Screen Elements ........................................................................................149
2.6 Background on Real-Ear Measurements using REM440 ............................................156
2.6.1 Required Items ........................................................................................................156
2.6.2 Calibration ..............................................................................................................158
2.6.3 Gain versus Response View.....................................................................................159
2.6.4 Real-ear Measurements on Open Fittings .................................................................160
2.6.4.1 Calibrate for Open Fit.................................................................................161
2.6.5 Probe Placement .....................................................................................................162
2.6.6 Stimuli for Real-ear Measures...................................................................................162
2.6.6.1 Tone Stimuli ..............................................................................................162
2.6.6.2 Speech Stimuli/ISTS ..................................................................................163
2.6.6.3 Composite Signals/ICRA ............................................................................163
2.6.6.4 What Stimulus to Choose? .........................................................................163
2.6.6.5 Presenting a Stimulus ................................................................................164
2.6.7 Working with Fitting Targets .....................................................................................165
2.6.7.1 Calculating the Target ................................................................................165
2.6.7.2 Choosing a Fitting Prescription ...................................................................165
2.6.7.3 DSL m[i/o] options....................................................................................166
2.6.7.4 NAL-NL1/NAL-NL2 options.........................................................................168
2.6.8 Comparing to the Hearing Aid Fitting Software...........................................................169
2.6.8.1 On Top Mode ............................................................................................169
2.6.8.2 Table Mode ...............................................................................................170
2.6.8.3 Show Cursor on the Graph .........................................................................170
2.4.1 Speech Intelligibility Index (SII) .................................................................................171
2.6.9 Display Peaks and Valleys .......................................................................................171
2.6.10 Preconditioning and Sweep Delay.............................................................................172
2.6.10.1 Preconditioning..........................................................................................172
2.6.10.2 Sweep Delay ..............................................................................................172
2.6.11 Smoothing a Curve ..................................................................................................172
2.6.12 Comparing Curves ...................................................................................................173
2.6.13 Managing Multiple Curves ........................................................................................173
2.6.13.1 Curve Display Options ...............................................................................174
2.6.13.2 Deleting Curves .........................................................................................174
2.6.13.3 Combined Screen View ..............................................................................174
2.6.13.4 Changing the Curve Colour ........................................................................174
2.7 Clinical application of Real-Ear Measurements using REM440 ..................................175
2.7.1 REUR/REUG Measurements....................................................................................175
2.7.1.1 Predicted REUR ........................................................................................177
2.7.1.2 REUG/REUR from a previous Session ........................................................178
2.7.1.3 REUR/REUG in both ears view...................................................................178
2.7.2 REAR/REAG Measurements ....................................................................................179
2.7.3 REIG Measurements ...............................................................................................181
2.7.4 RECD Measurements ..............................................................................................183
2.7.4.1 RECD using the clients own ear mould .......................................................184
2.7.4.2 RECD using the SPL Probe........................................................................187
2.7.4.3 Own Mould versus SPL Probe ....................................................................189
2.7.4.4 Predicted RECD Curve ..............................................................................189
2.7.4.5 Measured RECD compared to a predicted RECD ........................................189
2.7.4.6 Re-using a Coupler Curve ..........................................................................190
2.7.4.7 RECD from a previous Session ..................................................................191
2.7.4.8 Test Box/Coupler Base Fitting (Simulated REM) ..........................................191
2.7.4.9 The “Coupler Approach” .............................................................................191
2.7.4.10 The “Real-ear approach” ............................................................................193
2.7.4.11 Importing the RECD into the Hearing Aid Manufacturers Software ................193
2.7.4.12 Counselling the Parents in Visible Speech Mapping .....................................193
2.7.5 REOR/REOG measurements ...................................................................................194
2.7.6 Measuring Input/Output ............................................................................................195
2.7.7 Directionality Measurements.....................................................................................197
2.7.8 Binaural REM Measurements ...................................................................................198
2.5 FM System Verification...............................................................................................206
2.5.1 FM Transparency ....................................................................................................206
2.5.2 Ear Level, FM only ...................................................................................................209
2.6 Working with Individual Setups (Test Protocols)........................................................212
2.6.1 Selecting a Test Protocol..........................................................................................212
2.6.2 Creating new Test Protocols.....................................................................................213
2.6.2.1 REUG/REUR Settings................................................................................216
2.6.2.2 REAR/REAG Settings ................................................................................218
2.6.2.3 REIG Settings ...........................................................................................220
2.6.2.4 RECD Settings ..........................................................................................222
2.6.2.5 REOR/REOG Settings ...............................................................................224
2.6.2.6 Input/Output Settings .................................................................................226
2.6.2.7 Directionality Settings.................................................................................228
2.6.2.8 Pause Settings ..........................................................................................230
2.6.2.9 Visible Speech Mapping Settings ................................................................230
2.6.3 Combined Screen Setup ..........................................................................................231
2.6.4 Fitting Prescription Setup .........................................................................................232
2.6.4.1 DSL ..........................................................................................................233
2.6.4.2 NAL-NL2 Settings ......................................................................................234
2.6.4.3 NAL-NL1 Settings ......................................................................................235
2.6.4.4 Print Layout Settings ..................................................................................236
2.6.5 Finishing the Test Protocol .......................................................................................237
2.6.6 Changing a Test Protocol Permanently .....................................................................237
2.6.7 Changing a Test Protocol temporarily........................................................................238
2.6.8 Importing and Exporting Test Protocols .....................................................................238
2.6.8.1 Importing a Test Protocol ...........................................................................238
2.6.8.2 Exporting a Test Protocol ...........................................................................239
2.7 General Setup .............................................................................................................240
2.8 The REM 440 Menu Items ...........................................................................................242
2.9 Visible Speech Mapping (VSPM440) ...........................................................................245
2.9.1 About Visible Speech Mapping .................................................................................245
2.10 The Visible Speech Mapping Screen ..........................................................................246
2.11 Verification with Visible Speech Mapping...................................................................252
2.11.1 Considerations before you begin...............................................................................252
2.11.2 Visible Speech Mapping (in ear mode) ......................................................................252
2.11.3 Visible Speech Mapping (in coupler mode/test box mode) ..........................................253
2.12 Visual Tools for Counseling and Verification .............................................................256
2.12.1 Percentile Analysis ..................................................................................................256
2.12.2 Display Peaks and Valleys .......................................................................................257
2.12.3 Show Examples.......................................................................................................257
2.12.4 Speech Intelligibility Index ........................................................................................258
2.12.5 Speech Spectrum ....................................................................................................258
2.12.6 Dynamic Range View...............................................................................................259
2.12.7 Aided versus Unaided ..............................................................................................259
2.13 2.13 Visible Speech Mapping Settings........................................................................259
2.14 FAQ ............................................................................................................................262
2.15 Appendix 1 .................................................................................................................268
2.16 The REM440 Test Signal Characteristics ....................................................................268
2.17 REM PC Shortcuts ......................................................................................................270
2.18 Technical Specifications of the REM440 Software......................................................271
3 HIT440...........................................................................................................................272
3.1 HIT440 Quick Guide ....................................................................................................272
3.2 About HIT440 ..............................................................................................................274
3.3 HIT 440 Tests ..............................................................................................................275
3.4 Launching the HIT 440 Software from Databases .......................................................255
3.4.1 Launching HIT440 from Noah ...................................................................................255
3.4.2 Launching HIT440 from OtoAccess™ .......................................................................255
3.5 The HIT440 Screen......................................................................................................257
3.6 Hearing Instrument Testing using HIT440 ..................................................................262
3.6.1 Testing Hearing Instruments: ....................................................................................262
3.6.2 Testing bone anchored device using the SKS10 Skull Simulator .................................263
3.6.3 Installing the Skull Simulator License in the HIT440 Software: ....................................264
3.6.3.1 How to receive a new HIT license ...............................................................264
3.6.3.2 Activating the new HIT license ....................................................................265
3.6.3.3 Using the Skull Simulator protocol...............................................................266
3.6.3.4 Setup of SKS10 in the Affinity test chamber.................................................267
3.6.4 Running Pre-programmed Test Protocols ..................................................................269
3.6.5 Automatic Testing (Auto Run) ...................................................................................269
3.6.6 Preconditioning and Sweep Delay.............................................................................270
3.6.6.1 Preconditioning..........................................................................................270
3.6.6.2 Sweep Delay .............................................................................................270
3.6.7 Smoothing a Curve ..................................................................................................270
3.6.8 Show Cursor on the Graph .......................................................................................271
3.6.8.1 Managing Multiple Curves ..........................................................................271
3.6.8.2 Curve Display Options ...............................................................................272
3.6.8.3 Combined Screen View ..............................................................................272
3.6.8.4 Changing the Curve Color ..........................................................................272
3.6.9 Comparing Curves ...................................................................................................273
3.6.10 Comparing to the manufacturers specification sheets .................................................274
3.6.10.1 Telecoil Testing .........................................................................................274
3.7 Application of the HIT440 Tests..................................................................................276
3.7.1 Frequency Response ...............................................................................................276
3.7.2 Gain Curve ..............................................................................................................277
3.7.3 Harmonic Distortion .................................................................................................278
3.7.4 Intermodulation Distortion.........................................................................................280
3.7.5 Attack/Recovery Time ..............................................................................................280
3.7.6 Battery Current Drain/Battery Life Time .....................................................................282
3.7.7 Equivalent Input Noise .............................................................................................284
3.7.8 Reference Test Gain ................................................................................................285
3.7.9 Microphone Directionality .........................................................................................286
3.7.10 Single Frequency.....................................................................................................287
3.7.11 Response/Gain/Input/Output ....................................................................................288
3.7.12 Delay 289
3.7.13 OSPL90 290
3.5.1 3.7.14 Full-on Gain ..................................................................................................290
3.8 Working with Individual Setups (Test Protocols)........................................................292
3.8.1 Selecting a (standard) test protocol: ..........................................................................292
3.8.2 Designing a Customized Test Protocol ......................................................................293
3.8.2.1 Frequency Response Settings ....................................................................295
3.8.2.2 Gain Curve settings ...................................................................................298
3.8.2.3 Harmonic Distortion Settings ......................................................................299
3.8.2.4 Input/Output Settings .................................................................................301
3.8.2.5 Intermodulation Distortion Settings..............................................................303
3.8.2.6 Attack/Recovery Time Settings ...................................................................305
3.8.2.7 Battery Current Drain Settings ....................................................................307
3.8.2.8 Equivalent Input Noise Settings ..................................................................308
3.8.2.9 Reference Test Gain Settings .....................................................................312
3.8.2.10 Directionality Settings.................................................................................314
3.8.2.11 Single Frequency Settings..........................................................................315
3.8.2.12 Response/Gain/Input/Output Settings .........................................................317
3.8.2.13 Delay Settings ...........................................................................................318
3.8.2.14 Pause Settings ..........................................................................................320
3.8.3 Combined Screen Setup ..........................................................................................321
3.8.4 Print Layout Settings ................................................................................................322
3.8.5 Finishing the Test Protocol .......................................................................................323
3.8.6 Changing a Test Protocol Permanently .....................................................................324
3.8.7 Changing a Test Protocol Temporarily ......................................................................325
3.8.7.1 Importing and Exporting Test Protocols .......................................................325
3.8.7.2 Importing a Test Protocol ...........................................................................325
3.8.7.3 Exporting a Test Protocol ...........................................................................326
3.9 General Setup .............................................................................................................327
3.10 The HIT440 Menu Items ..............................................................................................330
3.11 HIT440 Software Technical Specifications ...............................................................332
3.12 Appendix 1 .................................................................................................................334
3.12.1 The HIT440 Test Signal characteristics .....................................................................334
3.13 Appendix 2: ................................................................................................................335
3.13.1 Connecting the TBS25 to Affinity
2.0
/Equinox
2.0
...........................................................335
4 PRINTING AND MAKING REPORTS .....................................................................337
4.1 The Print Wizard .........................................................................................................337
4.1.1 Designing a Customized Print Template ....................................................................339
4.1.2 Design Elements .....................................................................................................340
4.1.2.1 General Elements ......................................................................................340
4.1.2.2 Taskbar 343
4.2 Creating Reports ........................................................................................................344
4.2.1 Operation of the Report Editor ..................................................................................344
4.2.1.1 The Report Editor ......................................................................................344
4.2.1.2 The Template Editor ..................................................................................346
5 RECOVERY MANAGER ...........................................................................................347
6 CRASH REPORTS .....................................................................................................349
7 QUICK GUIDES ..........................................................................................................351
8 REFERENCES ............................................................................................................353
Affinity
2.0
Additional Information Page 1
1 AC440
1.1 About AC440 Module
AC440 is the PC-based audiometry module for the Affinity
2.0
and Equinox
2.0
hardware platforms.
The AC440 software is an independent two-channel audiometer. It features tone audiometry for air and
bone, speech testing and a variety of masking and signal types. Stimuli are presented using the PC
keyboard, mouse or a dedicated audiometry keyboard. Test results are displayed on screen and saved to the
associated database (e.g. Noah, OtoAccess). They are immediately available for inspection, hearing aid
fitting, printout, export, and so on. The AC440 module can also be operated external to a database in stand-
alone mode.
The module is flexible, enabling the individual clinician to tailor the system according to their specific
preferences. It permits the creation of an unlimited number of personalized test protocol settings and
functions for different purposes and/or for different clinicians working at the same location. The system also
provides you with the option to make individual print layouts, keep reports electronically, and compare actual
curves to previous sessions. These numerous setup options can be very helpful and time saving in the daily
clinical work environment.
In addition to the setup functions, the AC440 also contains counselling tools in order to help both patient and
relatives to get a better understanding of the consequences of hearing impairment and why hearing
amplification may be needed.
The AC440 contains the following tests:
Air Conduction Audiometry
o High Frequency Audiometry
o Multi Frequency audiometry
Bone Conduction Audiometry
Free Field Audiometry
Speech Audiometry
Masking Level Difference (MLD)
Master Hearing Aid (MHA) (counselling tool)
Hearing Loss Simulation (HLS) (counselling tool)
Short Increment Sensitivity Index (SISI)
Weber
Knaster
Stenger
Tone Decay Test
TEN test
QuickSIN
Affinity
2.0
Additional Information Page 2
1.2 Launching AC440 with Databases
1.2.1 Launching from OtoAccess™
Ensure that the Affinity is switched on and connected before opening the software suite. If the hardware is
not detected, a dialog box will appear asking if you want to run the Affinity Suite in Simulation mode, similar
to the following:
To start the Affinity Suite from OtoAccess™:
1. Open OtoAccess
2. Select the patient you want to work with by clicking on it; it will then highlight blue to indicate
selection.
3. If the patient is not yet listed:
- press the New client button
- fill in at least the mandatory fields, marked with a red asterisk.
- save the patient details by pressing the Save patient information button.
4. Double click on the Affinity Suite in the Select Instrument box.
For further instructions about working with the database, please see the operation manual for OtoAccess.
2
3
4
Affinity
2.0
Additional Information Page 3
1.2.2 Launching AC440 from Noah
Ensure that the Affinity is switched on and connected before opening the software module. If the hardware
is not detected, a dialog box will appear asking if you want to run the Affinity Suite in Simulation mode.
To start the Affinity Suite from Noah 4:
1. Open Noah 4
2. Search for and select the patient you want to work with from the left-hand side of the screen.
3. If the patient is not yet listed:
- Click on the Add a New Patient icon
- Fill in the required fields and click OK
4. Click on the Affinity Suite module icon at the top of the screen.
For further instructions about working with the database, please see the operation manual for Noah 4.
Affinity
2.0
Additional Information Page 4
1.2.3 Using the Tone Screen
The following section describes the elements of the tone screen.
Menu provides access to Print, Edit, View, Tests, Setup, and Help
Print allows for printing the session’s acquired data.
Save & New Session saves the current session in Noah or OtoAccess
and opens a new one.
Save & Exit saves the current session in Noah or OtoAccess and exits the
Suite.
Collapse the left side panel.
Go to Tone Audiometry activates the tone screen when in another test.
Go to Speech Audiometry activates the speech screen when in another
test.
Extended Range +20 dB extends the testing range and can be activated
when the testing dial setting gets within 55 dB of the maximum level of the
transducer.
Note that the extended range button will flash when it needs activation for
reaching higher intensities.
To switch on the extended range automatically, select the Switch extended
range on automatically by going to the setup menu.
Affinity
2.0
Additional Information Page 5
Fold an area so that it only shows the label or the buttons of that area.
Unfold an area so that all buttons and labels are visible
Show/hide areas can be found by right mouse clicking on one of the areas.
The visibility of the different areas as well as the space that they take on the
screen is locally saved to the examiner.
List of Defined Protocols allows for selecting a test protocol for the
current test session. Please refer to section 1.7 for more information about
protocols. Right mouse click on a protocol allows the current examiner to
set or deselect a default startup protocol.
Temporary Setup allows for making temporary changes to the selected
protocol. The changes will be valid for the current session only. After
making the changes and returning to the main screen, the name of the
protocol will be followed by an asterisk (*).
List of historical sessions accesses historical sessions for comparison
purposes. The audiogram of the selected session, indicated by the
orange background, is shown in colours as defined by the used symbol
set. All other audiograms that are selected by check marks show on
screen in the colours as indicated by the text colour of the date and time
stamp. Note that this listing can be resized by dragging the double lines
up or down.
Right Clicking on a historical session will allow you to see exactly
which measurements have been performed in that session. This is useful
when trying to find a special test amongst several sessions without
opening the session individually to find the data you need.
The tests which have been performed will have a green light next to them.
You can also click on Deselect all selected sessions overlays after
right clicking on the sessions to remove any historic session overlays you
have chosen to display.
Go to Current Session brings you back to the current session.
Affinity
2.0
Additional Information Page 6
Edit Mode button activates the editing function. Left clicking on the graph
will add/move a point to the position of the cursor.
By right clicking on a
point
it is possible to Delete the recorded point or the entire curve.
Furthermore,
right mouse click provides the option to Add unmasked
threshold, Add
no response, Add masked threshold, Add masked-
n
o-response threshold, Copy bone thresholds to other ear, and Hide
unmasked thresholds where masked
exist.
Mouse controlled audiometry enables you to do the audiometry using
the mouse only.
The stimulus is presented with the left mouse button, and
the threshold is stored with the right mouse button.
The dB step size button indicates to which dB step size increment the
system is currently is set. It rotates from 1 to 2 to 5 dB
and the larger
number indicates the setting.
The hide unmasked threshold will hide those unmasked thresholds
where masked thresholds exist.
Toggle Masking Help will activate or deactivate the Masking Help. The
masking help function can be removed from this interface through
amending the settings in the
Protocol Setup (See this in section 1.7.2.2).
For more information
on Masking Help, please see section 1.7.2.2 or
A
ppendix 4 for the Masking Help Quick Guide
Toggle Automasking will activate or deactivate the Automasking feature.
For more information on
Automasking, please refer to section 1.7.2.2 or to
Appendix
4 for the Masking Help Quick Guide.
Talk Forward activates the Talk Forward microphone. The arrow keys
can be used to set the talk forward level through the currently selected
transducers. The level will be accurate when VU meter indicates to be at
zero dB.
1
HF requires an additional license for the AC440. If not purchased, the button is grayed out.
2
MF requires an additional license for the AC440. If not purchased, the button is greyed out.
High Frequency
1
shows frequencies on the audiogram (up to 20 kHz for
the Affinity
2.0
/Equinox
2.0
). However, you will only be able to test in the
frequency range the selected headset is calibrated for.
High Frequency Zoom activates high frequency testing and zooms in on
the high frequency range. Please refer to section 1.6.1 for more
information on high frequency testing.
Single audiogram toggles between viewing the information of both ears
in a single graph and two separate graphs.
Multi frequencies
2
activate testing with frequencies in between the
standard audiometric test frequencies. The frequency resolution can be
adjusted in the AC440 setup.
Synchronize channels locks the two channels together. This function
may be used to perform synchronous masking.
Affinity
2.0
Additional Information Page 7
Selecting the Monitor Ch1 and/or Ch2 check boxes allow you to monitor
one or both channels through an external loudspeaker/headset connected
to the monitor input. The monitor intensity is adjusted by the arrow keys.
The Talk back check box enables you to listen to the patient. Note that
you need to be equipped with a microphone connected to the talk back
input and an external loudspeaker/headset connected to the monitor
input.
The Patient monitor opens an always-on-top window with the tone
audiograms and all its counselling overlays s
hown. This provides an
easier layout to counsel the patient.
The size and position of the patient
monitor gets saved for each examiner individually.
The Phonemes counselling overlay shows phonemes as it is configured
in the protocol that is currently i
n use.
The Sound examples counselling overlay shows pictures (png-
files) as they are set up in the protocol that is currently in use.
The Speech banana counselling overlay shows the speech area as it is
set up in the protocol that is currently in u
se.
The Severity counselling overlay shows the degrees of hearing loss as it
is set up in the protocol that is currently in use.
The Max. testable values overlay highlights the area beyond the
maximum intensity
that the system allows. This is a reflection of the
transducer calibration and
differs when the extended range is activated.
Selecting HL, MCL, UCL or Tinnitus sets the symbol types that are currently
in use by the audiogram
for different tests. HL stands for hearing level, MCL
stands for
most comfortable level and UCL stands for uncomfortable level.
Note that these buttons
display the unmasked right and left symbols of the
currently selected symbol set.
Each type of measurement is saved as a separate curve.
Binaural and Aided allows for indicating if the test is performed with hearing
aids or binaurally with corresponding symbols. The measurements will be
saved as separate curves.
In the Comments section you can type comments related to any audiometric
test. The used space by t
he comments area can be set by dragging the
double line with your mouse. Pressing the
Report editor button opens a
separate window for adding notes to the current session. The report editor
and comment box contain the same text. In case the formatting of t
he text is
important, this can only be set within the report editor.
Note that after saving the session changes can only be added to the report
within the sessions date. Therefore once the date changes you cannot add
anything further or make amendments. See section 4.2
for more information
about the Report Editor.
Affinity
2.0
Additional Information Page 8
The Output list for channel 1 provides the option to test through head
phones, bone conductor, free field speakers or insert phones. Note that the
system only shows the calibrated transducers.
The Input list for channel 1 provides the option to select pure tone, warble
tone, narrow band noise (NB) and white noise (WN).
Note that the background shading is according to the side that is selected,
red for right and blue for left.
The Output list for channel 2 provides the option to test through head
phones, free field speakers, insert phones or insert masking phone. Note
that the system only shows the calibrated transducers.
The Input list for channel 2 provides the option to select pure tone, warble
tone, narrow band noise (NB), white noise (WN) and TEN noise
3
.
Note that the background shading is according to the side that is selected,
red for right, blue for left, and white when off.
Man and Rev allows toggling between Manual and Reverse test modes. In
manual the stimulus is presented only when manually activated. In reverse
the signal is presented continuously until interrupted by the tone switch.
Pulsation allows for single and continuous pulsating presentation. The
duration of the stimulus can be adjusted in the AC440 setup.
Sim/Alt allows togging between Simultaneous and Alternate presentation.
Ch1 and Ch2 will present the stimulus simultaneously when Sim is
selected. When Alt is selected, the stimulus will alternate between Ch1 and
Ch2.
R+L allows for the system to perform binaural masking and tone
simultaneously. This setting will need to be enabled in each channel. The
test screen will turn grey to indicate this.
Masking indicates if channel 2 is currently in use as a masking channel
and in that way makes sure masking symbols are used in the Audiogram.
For example in paediatric testing through free field speakers, channel 2 can
be set as a second testing channel. Note that a separate store function for
channel 2 is available when channel 2 is not used for masking.
dB HL Increase and Decrease buttons allow increasing/decreasing the
intensities of channel 1 and 2.
The arrow keys on the PC keyboard can be used for increasing/decreasing
channel 1 intensities.
PgUp and PgDn on the PC keyboard can be used for
increasing/decreasing channel 2 intensities.
3
TEN noise requires an additional license for the AC440. If not purchased, the stimulus is not available.
Affinity
2.0
Additional Information Page 9
Stimuli buttons will light up when hovering the mouse over it. This indicates
the presentation of a stimulus.
A right mouse click in the Stimuli area will store a no response threshold. A
left mouse click in the Stimuli area will store the threshold at the current
position.
Channel 1 stimulation can also be obtained by pressing the space bar or
left Ctrl key on the PC keyboard.
Channel 2 stimulation can also be obtained by pressing the right Ctrl key on
the PC keyboard.
Mouse movements in the Stimuli area for both channel 1 and channel 2 can
ignored depending on the setup.
Frequency and Intensity display area shows what is currently presented.
To the left the dB HL value for channel 1 is shown and to the right for
channel 2 In the centre the frequency is displayed.
Notice that the dB dial setting will flash when trying to go louder than the
maximum available intensity.
The patient response indicator will appear inbetween these values when the
patient response button is depressed. The colour of this indicator will
depend upon which patient response side is used, a red light indicates the
right patient response and a blue light indicates the left patient response.
Frequency increase/decrease increases and decreases the frequency
respectively. This can also be obtained using the left and right arrow keys
on the PC keyboard.
Storing thresholds for channel 1 is done by pressing S or by a left mouse
click in the attenuator of channel 1. Storing a no response threshold can be
done by pressing N or by a right mouse click in the stimuli button of channel
1.
Storing thresholds for channel 2 is available when channel 2 is not the
masking channel. It is done by pressing <Shift> S or by a left mouse click
in the stimuli button of channel 2. Storing a no response threshold can be
done by pressing <Shift> N or by a right mouse click in the attenuator of
channel 2.
The hardware indication picture indicates whether the
hardware is
connected. Simulation mode is indicated when operating the software
without hardware.
When opening the Suite the system will automatically search for the
hardware. If it does not detect the hardware a dialog box pops up and asks
if you want to continue in simulation mode.
The Examiner indicates the current clinician who is testing the patient. The
examiner is saved with a session and can be printed with the results. This
information is taken from the login on the database from which the Suite is
launched, or the suite can be configured in the ‘General Suite Settings to
request an examiner name on start-up.
For each examiner, the Suite stores how it is set up with regards to the use
of space in the screen. The examiner will find that the suite starts up looking
the same as it did the last time they used the software. Also the examiner
can select which protocol must be selected at start up (by right mouse click
on the protocol selection list).
Affinity
2.0
Additional Information Page 10
1.3 The Speech Screen Elements
The following section describes the elements of the speech screen in addition to the tone screen:
Input levels sliders allow for adjusting the input level to 0 VU for the
selected input. This ensures that correct calibration is obtained for Mic1,
Mic2, CD1, and CD2.On the VU Meter the dial intensity is achieved when
the signal is at the 0 mark.
WR1, WR2 and WR3 (Word Recognition) allows selecting different speech
list setups as defined by the selected protocol. The labels of these lists
which go along with these buttons can also be customized in the protocol
setup. (See section
1.7.2.3).
The Output list for channel 1 provides the option to test through head
phones, bone conductor, free field speakers or insert phones. Note that the
system only shows the calibrated transducers.
The Input list for channel 1 provides the option to select white noise (WN),
speech noise (SN), microphone 1 or 2 (Mic1 and Mic2), CD1, CD2 and
wave file.
Note that the background shading of the speech Audiogram is according to
the side that is selected, red for right and blue for left.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384

Interacoustics affinity 2.0 Additional information

Category
Measuring, testing & control
Type
Additional information
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI