Cumberland CE Compliant Curtain Controller offers enhanced safety features for your grain bin. It features an enclosed limit switch and pulley covers, ensuring protection against hazardous moving parts. Installation is simplified with the included installation kit. The controller meets the latest safety standards, including Machinery Directive 2006/42/EC, providing peace of mind during operation.

Cumberland CE Compliant Curtain Controller offers enhanced safety features for your grain bin. It features an enclosed limit switch and pulley covers, ensuring protection against hazardous moving parts. Installation is simplified with the included installation kit. The controller meets the latest safety standards, including Machinery Directive 2006/42/EC, providing peace of mind during operation.

PNEG-620-2CE
CE Compliant Curtain Controller
Featuring the Enclosed Limit Switch and Pulley Covers
Installation and Operation Manual
PNEG-620-2CE
Version: 9.0
Date: 02-07-20
2 PNEG-620-2CE CE Compliant Curtain Controller
All information, illustrations, photos and specifications in this manual are based on the latest
information available at the time of publication. The right is reserved to make changes at any
time without notice.
PNEG-620-2CE CE Compliant Curtain Controller 3
CE Declaration of Incorporation
MACHINERY DIRECTIVE
2006/42/EC
1004 East Illinois Street, Assumption, IL, 62510, USA
+1 217 226 4429
The GSI Group declares that the machine, parts or equipment
Curtain Controllers
Models
I2430-50
I3630-50
• I4830-50
• I6030-50
Meet the following clauses of the Essential Requirements of the Machinery Directive 2006/42/EC:
1.1.2 and sub-clauses principles of safety integration
1.3.1 Risk of loss of stability
1.3.2 Risk of break-up during operation
1.3.7 Risk related to moving parts
1.3.8 Choice of protection against risks arising from moving parts
1.3.8.1 Moving transmission parts
1.3.8.2 Moving parts involved in the process
1.3.9 Risks of uncontrolled movements
1.4 Required characteristics of guards and protective devices
1.4.1 General requirements
1.4.2 Special requirements for guards
1.4.2.1 Fixed guards
1.5.4 Errors of fitting
1.5.5 Extreme temperatures
1.5.6 Fire
1.5.7 Explosion
1.5.8 Noise
4 PNEG-620-2CE CE Compliant Curtain Controller
1.5.9 Vibrations
1.5.13 Emissions of hazardous materials and substances
1.6 Maintenance
1.6.1 Machinery maintenance
1.6.4 Operator intervention
1.7 Information
1.7.1 Information and warnings on the machinery
1.7.1.1 Information and information devices
1.7.2 Warning of residual risks
1.7.4 Instructions
1.7.4.1 General principles for the drafting of instructions
1.7.4.2 Contents of the instructions but not inclusive of sub-clause (u)
1.7.4.3 Sales literature
This declaration applies only to the above machines and does not imply conformity by any other items
of equipment fitted to or connected with the above machines.
The equipment above must not be put into service until the machinery into which it is to be
incorporated has been declared in conformity with the provisions of all relevant Directives, nor until
these components have been assembled in the manner recommended in the attached manufacturers
instructions.
Signed:
Name:
Date:
CE Declaration of Incorporation
MACHINERY DIRECTIVE
2006/42/EC
1004 East Illinois Street, Assumption, IL, 62510, USA
+1 217 226 4429
Table of Contents
PNEG-620-2CE CE Compliant Curtain Controller 5
Contents
Chapter 1 Safety .....................................................................................................................................................6
Safety Guidelines ...................................................................................................................................6
Cautionary Symbols Definitions .............................................................................................................7
Safety Cautions ......................................................................................................................................8
Safety Sign-Off Sheet ..........................................................................................................................10
Electrical Safety ...................................................................................................................................11
Safety Guarding Requirements ............................................................................................................12
Correct Use ..........................................................................................................................................12
Safety in Maintenance ..........................................................................................................................12
Lifting ....................................................................................................................................................13
Noise ....................................................................................................................................................13
Chapter 2 Safety Decals ......................................................................................................................................14
Chapter 3 Specifications .....................................................................................................................................15
Chapter 4 Installation ..........................................................................................................................................16
Latchout Switch ....................................................................................................................................27
Chapter 5 Troubleshooting .................................................................................................................................29
Chapter 6 Maintenance ........................................................................................................................................30
Chapter 7 Parts List .............................................................................................................................................31
Enclosed Limit Switch Assembly ..........................................................................................................32
Motor Components ...............................................................................................................................34
Chapter 8 Installation Kit .....................................................................................................................................38
AC180-A Installation Kit (Purchased Separately) ................................................................................38
AC180-B Installation Kit (Purchased Separately) ................................................................................39
Chapter 9 Warranty ..............................................................................................................................................41
6 PNEG-620-2CE CE Compliant Curtain Controller
1. Safety
Safety Guidelines
Safety guidelines are general-to-specific safety rules that must be followed at all times. This manual is
written to help you understand safe operating procedures and problems that can be encountered by
the operator and other personnel when using this equipment. Read and save these instructions.
As owner or operator, you are responsible for understanding the requirements, hazards, and precautions
that exist and to inform others as required. Unqualified persons must stay out of the work area at all times.
Alterations must not be made to the equipment. Alterations can produce dangerous situations resulting in
SERIOUS INJURY or DEATH.
This equipment must be installed in accordance with the current installation codes and applicable
regulations, which must be carefully followed in all cases. Authorities having jurisdiction must be consulted
before installations are made.
When necessary, you must consider the installation location relative to electrical, fuel and water utilities.
Personnel operating or working around equipment must read this manual. This manual must be delivered
with equipment to its owner. Failure to read this manual and its safety instructions is a misuse of the
equipment. ST-0001-4
1. Safety
PNEG-620-2CE CE Compliant Curtain Controller 7
Cautionary Symbols Definitions
Cautionary symbols appear in this manual and on product decals. The symbols alert the user of potential
safety hazards, prohibited activities and mandatory actions. To help you recognize this information, we
use the symbols that are defined below.
DANGER
WARNING
CAUTION
NOTICE
This symbol indicates an imminently hazardous situation
which, if not avoided, will result in serious injury or death.
This symbol indicates a potentially hazardous situation
which, if not avoided, can result in serious injury or death.
This symbol indicates a potentially hazardous situation which,
if not avoided, can result in minor or moderate injury.
This symbol is used to address practices not related to
personal injury.
This symbol indicates a general hazard.
This symbol indicates a prohibited activity.
This symbol indicates a mandatory action.
ST-0005-2
1. Safety
8 PNEG-620-2CE CE Compliant Curtain Controller
Safety Cautions
Use Personal Protective Equipment
Eye
Protection
Hearing
Protection
Hand
Protection
Head
Protection
Respiratory
Protection Foot
Protection
Fall
Protection
• Use appropriate personal protective equipment:
• Wear clothing appropriate to the job.
• Remove all jewelry.
• Tie long hair up and back.
ST-0004-1
ST-0002-1
1. Safety
PNEG-620-2CE CE Compliant Curtain Controller 9
ST-0003-1
ST-0021-2
ST-0027-4
ST-0036-2
1. Safety
10 PNEG-620-2CE CE Compliant Curtain Controller
Safety Sign-Off Sheet
Below is a sign-off sheet that can be used to verify that all personnel have read and understood the safety
instructions. This sign-off sheet is provided for your convenience and personal record keeping.
Date Employee Name Supervisor Name
ST-0007
1. Safety
PNEG-620-2CE CE Compliant Curtain Controller 11
Electrical Safety
Equipment shall include:
1. Fuse protected main power supply.
a. The electrical supply should include earth leakage protection, (eg) Residual Current Device
(RCD) or Residual Current Circuit Breaker (RCCB), to provide automatic disconnection in the
event of a fault.
2. Lockable main safety disconnect.
a. Disconnects all electrical power.
3. Lockable motor service disconnect.
a. Adjacent to each Curtain Controller.
b. Disconnects all power to all safe servicing.
4. Emergency stops.
a. Stops all equipment immediately when pressed.
b. Must remain engaged until manually disengaged.
c. Equipment shall not immediately re-start when the emergency stop is re-set.
5. Protective Earth/Ground.
a. The electrical supply must include a properly designed protective earth system (PE), with
connection to all exposed conductive parts.
b. All equipment shall be connected to protective earth at the terminal provided.
6. Control System
a. The Curtain Controller is designed to operate under automatic temperature controls, which shall
be provided by the installer.
7. The control system shall include.
a. Short circuit protection.
b. Start/stop controls.
c. Equipment shall not immediately re-start following re-establishment of power.
d. All electrical design, installation and testing must be carried out by a qualified electrical engineer,
in accordance with EU Directives and Standards, local laws and codes.
1. Safety
12 PNEG-620-2CE CE Compliant Curtain Controller
Safety Guarding Requirements
1. Guards and covers provided with the equipment must be fitted at all times when the equipment
is in operation.
2. Never operate the equipment with any of the guards removed.
Correct Use
1. The Curtain Controller shall be used only for raising and lowering ventilation control curtains on
poultry, pig or other agricultural livestock buildings.
2. It shall not be used for:
• Any domestic uses.
• Shutters, awnings, doors and windows.
• Vents on green houses.
• Garage doors.
• Winching or towing.
• Any other uses not detailed in this manual.
3. This equipment shall not be used in any potentially explosive environment.
4. Do not modify or alter the equipment from its original specification.
5. Do not exceed the maximum safe lift capacity stated on the rating plate and in table on Page 14.
Safety in Maintenance
1. Only attempt maintenance or repair if competent to do so.
2. Lock out and tag power before any maintenance.
3. Replace all guards and covers before re-starting. (See Figure 1A.)
Figure 1A
Should the curtain or wire ropes become jammed, the Curtain Controller can
generate lift forces up to 10 times the safe working load. Ensure all structures are
capable of withstanding these loads.
1. Safety
PNEG-620-2CE CE Compliant Curtain Controller 13
Lifting
1. Do not attempt to lift the Curtain Controller un-aided.
2. Seek help from others.
3. Use lift equipment.
Figure 1B
Noise
Under normal operation noise levels at a position 1 m from the drive unit and 1.6 meters above the ground
do not exceed 70 dBa, continuous “A” weighted sound pressure or 63 Pa, instantaneous “C” weighted
sound pressure.
14 PNEG-620-2CE CE Compliant Curtain Controller
2. Safety Decals
Safety decals are available in non-English versions. Please request LPAK-0010-** if these were not
delivered with the equipment.
DC-2213 should be applied
in these locations.
CE Rating plate should be placed here.
The GSI Group
1004 E. Illinois St.
Assumption, IL. 62510
USA
CURTAIN CONTROLLER
Model I6030-50
1524 mm
7.8 m/h
25 RPM
1818 kg
1
0.098 kW
220-240 V (AC)
0.79 A
1 A
50 Hz
Nema 4/IP65
123456789
03 January 2013
Stroke
Speed
Motor
Motor
Phase
Voltage
FLA
Fuse rating
Maximum safe pull
Service factor
SN
Date
1~
DC-2213GSI Group 217-226-4421
PNEG-620-2CE CE Compliant Curtain Controller 15
3. Specifications
Model # Weight Motor
(W) Voltage
(VAC) FLA
(A) Stroke
(mm) Speed
(m/h) Maximum Safe
Pull * (kg)
I2430-50 47 kg
98 220-240 0.79
610
7.9 900
I3630-50 54 kg 914
I4830-50 61 kg 1219
I6030-50 69 kg 1524
* Assumes direct pull, with no pulley reduction.
16 PNEG-620-2CE CE Compliant Curtain Controller
4. Installation
1. Inspect and check for damage or faults.
2. Select installation option.
Figure 4A Outside, End Wall, 2:1 Pulley Ratio
Figure 4B Outside, End Wall, 1:1 Pulley Ratio
4. Installation
PNEG-620-2CE CE Compliant Curtain Controller 17
Figure 4C Outside Side Wall Mount, 2:1 Pulley Ratio
Figure 4D Inside End Wall Mount, 1:1 Pulley Ratio
3. Determine required top pulley arrangement.
• Pulleys are accessed via the top cover of the curtain controller.
4. Installation
18 PNEG-620-2CE CE Compliant Curtain Controller
Figure 4E
Two (2) curtains, one left and one right.
One curtain to right.
One curtain to left.
Curtain controller installed horizontally.
Remove top plugs
for this installation.
4. Installation
PNEG-620-2CE CE Compliant Curtain Controller 19
4. Alter pulley arrangement. (See Figure 4F.)
Figure 4F
5. Mark position of top and centre. (See Figure 4G.)
Figure 4G
Ref # Description Ref # Description
APulley Support Plate D5/16" Bolt
BPulley E Pulley Space
CShoulder Bolt FR-Clip
4. Installation
20 PNEG-620-2CE CE Compliant Curtain Controller
6. Mark location for first screw. (See Figure 4H.)
Figure 4H
7. Insert first screw. (See Figure 4I.)
Figure 4I
Ref # Description
G3/8" x 3" Lag Bolt
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Cumberland CE Compliant Curtain Controller Owner's manual

Type
Owner's manual

Cumberland CE Compliant Curtain Controller offers enhanced safety features for your grain bin. It features an enclosed limit switch and pulley covers, ensuring protection against hazardous moving parts. Installation is simplified with the included installation kit. The controller meets the latest safety standards, including Machinery Directive 2006/42/EC, providing peace of mind during operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI