3 Bentone
General
Table of contents
1. General Information _____________________________________________ 4
2. Technical data BG950 ___________________________________________ 7
2.1 Burners are intended for use at: ________________________________ 7
2.2 Dimensions _________________________________________________ 7
2.3 Description _________________________________________________ 10
3. General instruktions ____________________________________________ 12
3.1 General instructions _________________________________________ 12
3.2 Installation and maintenance instructions _______________________ 12
3.3 Instructions ________________________________________________ 12
3.4 Inspection and maintenance __________________________________ 12
3.5 Start up ___________________________________________________ 12
3.6 Commissioning of installation _________________________________ 12
4. Installation ____________________________________________________ 13
4.1 Delivery check ______________________________________________ 13
4.2 Preparations for installation ___________________________________ 13
4.3 Gas supply _________________________________________________ 13
4.4 Electric connection __________________________________________ 13
4.5 Skeleton diagrams __________________________________________ 14
4.6 Handling and lifting instruction ________________________________ 15
4.7 Mounting on the boiler _______________________________________ 16
4.8 Inspection of gas nozzle before commissioning __________________ 17
4.9 Leakage control ____________________________________________ 18
4.10 Gas nozzle _________________________________________________ 19
4.11 Setting Air damper __________________________________________ 20
4.12 Damper motor, air volume ____________________________________ 20
4.13 Adjustment of gas flow _______________________________________ 20
5. Setting the burner ______________________________________________ 21
5.1 Setting the air pressure switch ________________________________ 21
5.2 Setting the min. gas pressure switch ___________________________ 22
6. Multi-bloc, MB-VEF, MBC-VEF___________________________________ 23
6.1 MBC 1900 - 3100 VEF _______________________________________ 23
6.2 Technical data ______________________________________________ 24
6.3 Mounting instruction - impulse lines PL, PF and PBr ______________________________ 24
6.4 Adjustment possibilities ______________________________________ 24
6.5 Double Solenoid Valve Gas-air-ratio control Type MBC-...-VEF _____ 25
6.6 Mounting __________________________________________________ 27
6.7 Installation of pulse lines ______________________________________ 27
6.8 Setting the pressure controller _________________________________ 28
6.9 Recommended excess air when using default setting _____________ 29
6.10 Determining the gas quantity for the system _____________________ 29
6.11 Calculating the quantity of gas supplied ________________________ 31
7. Service ________________________________________________________ 32
7.1 Servicing the combustion assembly ____________________________ 32
7.2 Servicing air dampers ________________________________________ 33
7.3 Replacement of damper motor, air _____________________________ 34
7.4 Vibration ___________________________________________________ 35
7.5 Flame monitoring and ionisation current check ___________________ 36
7.6 UV detector ________________________________________________ 36
8. Handing over of the installation __________________________________ 37
9. Fault location, functional troubles ________________________________ 37
10. Electric equipment ___________________________________________ 38
10.1 Safety system ______________________________________________ 38
10.2 Wiring diagram LFL1.... ______________________________________ 39
10.3 List of components __________________________________________ 40
10.4 Leakage control Dungs VPS 504 ______________________________ 42
11. Troubleshooting _____________________________________________ 44
12. EU Declaration of conformity _________________________________ 47
14. General instructions for gasburners ____________________________ 48