Alpha Ground Mount Security Bar is designed to provide additional security for enclosures in both indoor and outdoor applications. The kit includes all the necessary hardware for installation, and the detailed instructions will guide you through the process. Once installed, the security bar will help to prevent unauthorized access to the enclosure and its contents. It can be used for a wide range of applications, including securing equipment in data centers, server rooms, and other sensitive areas. The Alpha Ground Mount Security Bar is a cost-effective and easy-to-install solution for improving the security of your valuable equipment. Some of the features include:

Alpha Ground Mount Security Bar is designed to provide additional security for enclosures in both indoor and outdoor applications. The kit includes all the necessary hardware for installation, and the detailed instructions will guide you through the process. Once installed, the security bar will help to prevent unauthorized access to the enclosure and its contents. It can be used for a wide range of applications, including securing equipment in data centers, server rooms, and other sensitive areas. The Alpha Ground Mount Security Bar is a cost-effective and easy-to-install solution for improving the security of your valuable equipment. Some of the features include:

Tools and Materials Required
• HandDrill
• CenterPunch
• 4-footLevel
• 7/16"SocketDriverwithExtension
• 1/8"DrillBit
• #K(9/32"or.281")DrillBit
• TapeMeasure
• MaskingTape
• Pencil
• UtilityKnife
• Vacuum(Toremovedrillswarffromcabinetinterior)
• Lock(seeFig.1fordimensions)
SecurityBarFieldInstallationInstructionsFiel
ForFPE,UPE-3,UPE-6,UPE-M3,UPE-M6,PNSeriesandCESeriesEnclosures
Eachsecuritybarkitcontainsthepartsandaccessoriesneededtosecureoneenclosuredoor.Enclosureswithbothafrontandback
door,requiretwokits(expectwherenotedbelow).DetailedplacementspecicationsforeachsupportedenclosureareintheSecurity
BarFieldInstallationManual(SearchforP/N745-847-C1-001)availableatwww.alpha.com.
Installing the Security Bar
Theinstallationoutlinedinthisdocumentappliestoeachof
thesupportedenclosures.SeePage2forinstallationdetail
gures.LockdimensionsmustconformtoFigure1.
Ifnecessary,placementspecicationsforeachsupported
enclosureareintheSecurityBarFieldInstallationManual
(AlphaP/N745-847-C1-001)availableatwww.alpha.com.
B
A
C
A=5/16"
B=3/4"
C=21/2"
Figure1,LockDimensions
1. Usinga4-ftlevelandapencil,marktheenclosurewherethe
topofthesidebracketswillbeplaced,seeFigure2.
2. Positionthesidebracketandcenterpunchtheholes
3. Removethedoor.Protectanyelectronicequipmentfrom
drillshavingsbeforedrilling,andensurethedrillbitwillnot
contactanyequipmentasitpassesintotheenclosure.
Page1of2
Onlyqualiedpersonnelshouldcompletethisinstallation.Irreparabledamagemayoccurtothe
enclosureorequipmentifnotinstalledcorrectly.
CAUTION!
4. Pilotdrillthesidebracketholesusingthe1/8"drillbit.
5. Drillthetwotopholesusinga#Kdrillbit.SeeFigure3.
6. Usingthesidebracketsastemplates,markanddrillthetwo
bottomholes.
7. Installthesidebrackets,seeFigure4,andreplacethedoor.
8. Installthesecuritybarinthesidebrackets.Positionanduse
thelockbracketasatemplateformarkingitsholes.
9. Drillthelockbracketholes.
NOTE:
Wherenecessary,usetheutilityknifetocutand
removeinsulationfromthehardwarearea.
10. Installthelockbracket.SeeFigure5.
11. InstalltheotherSecurityBarSideandLockBracketsby
repeatingSteps1–8.
12. Removeanymetalshavings.
13. SecuretheenclosurewiththeSecurityBar,LockandLock
Guard.SeeFigure6.
Enclosure Color AlphaPartNumber
#ofRequired
Kits
KitComponentsDescription(Qty)
UPE
SeafoamGreen 745-847-20
1
• LockBracket(2)
• SideBracket(4)
• SecurityBar(2)
• LockGuard(2)
• CarriageBolt1/4"-20X3/4"(12)
• LockWasher1/4"(12)
• FlatWasher1/4"(12)
• HexNut1/4"-20(12)
Gray 745-847-21
PN
SeafoamGreen 745-847-20
2
Gray 745-847-21
CE
SeafoamGreen 745-847-20
2
Gray 745-847-21
FPE
SeafoamGreen 745-847-22
1
• LockBracket(4)
• SideBracket(8)
• SecurityBar(4)
• LockGuard(4)
• CarriageBolt1/4"-20X3/4"(24)
• LockWasher1/4"(24)
• FlatWasher1/4"(24)
• HexNut1/4"-20(24)
Gray 745-847-23
PineGreen 745-847-24
White 745-847-25
NOTE:
Onenclosuredoorswithlouvers,positiontheLock
Brackettoeithersideofthelouvers.SeePage2.
AlphaTechnologiesreservestherighttomakechangestotheproductsandinformationcontainedinthisdocumentwithoutnotice.
Copyright©2006AlphaTechnologies.AllRightsReserved.Alpha
®
isaregisteredtrademarkofAlphaTechnologies.memberofTheAlphaGroup™isatrademarkofAlphaTechnologies.
745-847-C2-001,Rev.B(08/2013)
Formoreinformationvisitwww.alpha.com
UnitedStates Bellingham,WashingtonTel:3606472360Fax:3606714936
Canada Burnaby,BritishColumbiaTel:6044301476Fax:6044308908
member of
The Group
T
M
Page2of2
Detailed specications for each supported enclosure are in the security bar eld installation manual (search for Alpha part
number 745-847-C1-001) available at www.Alpha.com. The FPE enclosure is shown below as an example.
Figure4,SideBracketInstallation
(Left bracket installation is mirrored)
(FPE Enclosure shown as an example))
CARRIAGE BOLT
1/4"-20 X 3/4"
FLAT WASHER 1/4" (2 PLACES)
LOCK WASHER 1/4" (2 PLACES)
NUT 1/4"-20 (2 PLACES)
ENCLOSURE DOOR
LOCK BRACKET
Figure5,LockBracketAlignmentandInstallation
LOCK BAR
LOCK
LOCK GUARD
Figure6,LockGuardInstallation
Figure3,DrillLocations
Figure2,MarkingBracketLocations
Thesecuritybarandlockbracketlockholesmustlineupbeforesecuringthelock
brackettotheenclosuredoor,seeFigure5.
NOTE:
Step1
Step2
Step3
Step4
  • Page 1 1
  • Page 2 2

Alpha Ground Mount Security Bar Quick start guide

Type
Quick start guide

Alpha Ground Mount Security Bar is designed to provide additional security for enclosures in both indoor and outdoor applications. The kit includes all the necessary hardware for installation, and the detailed instructions will guide you through the process. Once installed, the security bar will help to prevent unauthorized access to the enclosure and its contents. It can be used for a wide range of applications, including securing equipment in data centers, server rooms, and other sensitive areas. The Alpha Ground Mount Security Bar is a cost-effective and easy-to-install solution for improving the security of your valuable equipment. Some of the features include:

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI