SBC PCD7.L6xx room operation device Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the SBC PCD7.L6xx room operation device Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Document 26-859; Edition ENG07 │ 2015-06-04
Manual
Room controller units PCD7.L6xx,
Extension modules, Accessories
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Content
0-1
0
0 Content
0 Content
0.1 Document History ............................................................................................... 0-2
0.2 About this manual .............................................................................................. 0-2
0.3 Brands and trademarks ..................................................................................... 0-2
1 Assembly instructions
2 Analogue room control units
2.1 Techn.specicationsofanalogueroomcontrolunitsPCD7.L630-.L632 ......... 2-2
2.1.1 TechnicaldataforPCD7.L630 ........................................................................ 2-4
2.1.2 TechnicaldataforPCD7.L631 ....................................................................... 2-5
2.1.3 TechnicaldataforPCD7.L632 ........................................................................ 2-6
3 Digital room control units
3.1 TechnicalspecicationsofdigitalroomcontrolunitsPCD7.L640-.L644 .......... 3-2
3.1.1 TechnicaldataforPCD7.L640 ........................................................................ 3-4
3.1.2 TechnicaldataforPCD7.L641 ........................................................................ 3-5
3.1.3 TechnicaldataforPCD7.L642 ........................................................................ 3-6
3.1.4 TechnicaldataforPCD7.L643 ........................................................................ 3-8
3.1.5 TechnicaldataforPCD7.L644 ........................................................................ 3-10
Operation / Menu structur ............................................................................... 3-12
3.1.6 TechnicaldataforPCD7.L660/PCD7.L661(versionsSV1.5andSV6.1) ..... 3-13
3.1.7 TechnicaldataforPCD7.L662/PCD7.L663(versionSV2.8K) ...................... 3-18
3.2 TechnicaldataforPCD7.L650 ........................................................................... 3-23
3.2.1 Light: 2lightgroupswithsensorcommands'on'and'off'
Shade: 2groupsup/downviaelectronicsensor ............................. 3-25
3.2.2 Light: 1lightgroupsensoron,automaticoffaftertimedelay
Shade: 2groupsshadesup/down ..................................................3-26
3.2.3 Light: 1lightgroupsensoron,offvianetworkcommand
Shade: 2groupsshadesup/down ..................................................3-27
3.2.4 Light: 2groupsviaswitch
Shade: 2groupsviachangeovercontactsup/down ....................... 3-28
4 Cables for room controllers and room control units
A Appendix
A.1 Icons ................................................................................................................... A-1
A.2 Order codes ....................................................................................................... A-2
A.3 Contact .............................................................................................................. A-4
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Content
0-2
0
0.1 Document History
Date Version Changes Remarks
2008-09-30 EN01 - TranslationofGermanversion
2010-05-03 EN02 PCD7.L630 Connectionwithspringterminalblock,
notwithRJ-11
2010-09-15 EN03 PCD7.L67x Newtypesofconnectingcablesintegrated
2013-02-15 EN04 PCD7.L670
PCD7.L672
Newnumberingofthestrands
2013-09-27 EN05 Newlogoandnewcompanyname
2013-11-13 EN06 A.2 PCD7.L666don’tworkwithIR
2015-06-04 ENG07 Ch01
A.3
Newchapter:Assemblyinstructions
Newphonenumbers
0.2 About this manual
Seethesectionintheappendixinrelationtosomeoftheterms,abbreviationsand
thereferencesusedinthismanual.
0.3 Brands and trademarks
SaiaPCD
®
andSaiaPG5
®
areregisteredtrademarksofSaia-BurgessControlsAG.
Technicalmodicationsarebasedonthecurrentstate-of-the-arttechnology.
Saia-BurgessControlsAG,2015.
©
Allrightsreserved.
PublishedinSwitzerland
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Assembly instructions
1-1
1
1.5 m
Avoid direct exposure to sunlight or
light from powerful lamps.
Donotinstallnexttoheatsourcessuch
asheaters,refrigerators,lampsetc.
Donotinstallnexttowindowsanddoors
becauseofdraughts.
1 Assembly instructions
Theroomcontrolunitsmustonlybeinstalledandconnectedbyanexpertin
accordancewiththewiringdiagram.Existingsafetystandardsmustalsobe
observed.
Theroomcontrolunitscanonlybeusedtoregulatethetemperatureindry,
closedrooms.Themaximumpermissiblerelativehumidityis 90%,non-
condensing.
Precisetemperaturemeasurementissubjecttocertainrequirementsastothe
positioningofthetemperaturesensors.Thisappliesbothtotheroomcontrol
deviceitselfandtotheexternallyconnectedtemperaturesensor.
Thedevicecanbemounteddirectlyonthewallorush-mountedwithina
pattressbox.
Donotlocatedthecontroldevice/
compact room controller in the path
ofdraughtsfromclimatecontrolor
ventilationsystems.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Assembly instructions
1-2
1
Saia® DDC
Saia®
DDC
1
Assemblingthe
housingbase
2
Wiringtothedevice
3
Unlocking
Please ensure:
●
thatallwiresarescreweddowntight
●
thattheconnectingplugisproperlyengaged
●
thattheventilationslotsareplacedaboveandbelow(positioning)
●
thatthedeviceismountedhorizontally.
To prevent a premature oxidation and yellowness of the plastic enclosure of
the room control unit, the following installation conditions has to be prevent
(non-exhaustive list):
Exposuretointensivesunlightorintensivearticiallights(intensiveneontubes
lightinparticular)
Exposuretochemicalproductssuchas:intensive&frequentuseofcleaning
chemicalproducts(Bleach,…),disinfectantspraysetc.
Exposuretohighhumidityrates;saltedhumiditycouldincreasefurtherthe
oxidation
Exposuretohighratioofoxygen
Exposuretohighheat
4
Removethecase
Mounting
Removal
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Analogue room controller units
2-1
2
2 Analogue room control units
PCD7.L63x Generaltechnicalspecication
- - -
PCD7.L630 Room temperature sensor
PCD7.L631 Roomtemperaturesensorwithsetpointsetting
PCD7.L632 Roomtemperaturesensorwithsetpointsetting,
presencesensorandLED
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Analogue room controller units
2-2
Technicalspecications
2
2.1 Techn.specicationsofanalogueroomcontrolunitsPCD7.L630-.L632
RJ 11
PCD7.L671
potentiometer
consigne
LED
comfort
cateur de temperature
button d'occupation
10k, linear
bleu
jaune 5V
1k5
P1
GND
S
verte
rouge
noir
blanc
GND
Pin allocation PCD7.L630 - .L632
Signal
Terminal Description
Temperature sensor
S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40°C.
Presencesensor
S,GND Floatingsensorusingthetemperaturesensor.
Setpointsetting
5V,P1,GND Potentiometer(10kΩ,linear)forsettingacong-
urablesetpointdisplacement.Seedescriptionof
CongFBoxorregisters(reg.104)
LED
LED,GND LEDtodisplayComfortmode.Comfortmode=5V,
otherwise0V.(5V,2mAmax.)
PCD7.L671 connecting cable - colour table
Colour Terminal
Description
White S
Temperature/presence sensor
Black GND
Ground
Red P1
Potentiometercentretap
Green
Not used
Yellow 5V
Potentiometerpowersupply
Blue LED
LEDwith1.5kΩseriesresistance.(max.2mA)
Note
AllinformationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheroomcontroller
conguration.SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Analogue room controller units
2-3
Technicalspecications
2
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Analogue room controller units
2-4
Technical data
2
2.1.1 TechnicaldataforPCD7.L630
GND
S
Temperature sensor
black
white
Room temperature sensor
Pin allocation for PCD7.L630
Signal
Terminal Description
Temperature sensor
S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40 °C.
Pin allocation for connecting cable PCD7.L671
Colour Terminal
Description
White S
Temperature/presence sensor
Black GND
Groundforthetemperaturesensor
Note
All informationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Analogue room controller units
2-5
Technical data
2
2.1.2 TechnicaldataforPCD7.L631
RJ 11
PCD7.L671
potentiometer
Consigne
capteur de
température
10k, linéare
bleu
jaune 5V
P1
GND
S
verte
rouge
noir
blanc
GND
Roomcontrolunitwithtemperaturesensorandsetpointsetting.
Pin allocation for PCD7.L631
Signal
Terminal Description
Temperature sensor
S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40 °C.
Setpointsetting
5V,P1,GND Potentiometertosetacongurablesetpointdis-
placement.SeedescriptionofCongFBoxorregis-
ters(reg.104)
PCD7.L671 connecting cable - colour table
Colour Terminal
Description
White S
Temperature sensor
Black GND
Ground
Red P1
Setpointpotentiometer
Green
Not used
Yellow 5V
Setpointpotentiometerpowersupply
Blue LED
LEDwith1.5kΩseriesresistance.(max.2mA)
Note
All informationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
Analogue room controller units
2-6
Technical data
2
2.1.3 TechnicaldataforPCD7.L632
RJ 11
PCD7.L671
potentiometer
consigne
LED
comfort
cateur de temperature
button d'occupation
10k, linear
bleu
jaune 5V
1k5
P1
GND
S
verte
rouge
noir
blanc
GND
Roomcontrolunitwithtemperaturesensor,setpointsettingandilluminatedpresence
sensor.WhenthecontrollerisworkinginComfortmode,thesemi-transparentsensor
lightsup.
Pin allocation for PCD7.L632
Signal
Terminal Description
Temperature sensor
S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40 °C.
Setpointsetting
5V,P1,GND Potentiometertosetacongurablesetpointdis-
placement.SeedescriptionofCongFBoxorregis-
ters(reg.104)
LED
LED,GND Thepresencesensorlightsupwhenthecontrolleris
runninginComfortmode.
PCD7.L671 connecting cable - colour table
Colour Terminal
Description
White S
Temperature sensor
Black GND
Ground
Red P1
Setpointpotentiometer
Green
Not used
Yellow 5V
Setpointpotentiometerpowersupply
Blue LED
Presencesensorillumination
White S
Temperature/presence sensor
Note
All informationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheconguration.See
descriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-1
3 Digital room control units
PCD7.L64x Generaltechnicalspecication
- - -
PCD7.L640 Roomtemperaturesensorwithsetpointsetting
PCD7.L641 Roomtemperaturesensorwithsetpointsetting,
presencesensorandLED
PCD7.L642 Roomtemperaturesensorwithsetpointsetting,
presencesensor,LEDandfancontrol
PCD7.L643 Roomtemperaturesensorwithfunctionkeysand
LCDdisplayforHeaVACfunctions.
PCD7.L644 Roomtemperaturesensorwithfunctionkeysand
LCDdisplayforHeaVACfunctions,andlightand
shadefunctions
- - -
PCD7.L660 Mobileroomcontrolunitwithinfraredinterface,
temperaturesensor,functionkeysanddisplay
PCD7.L661 infraredreceiver
PCD7.L662 Mobileroomcontrolunitwithinfraredinterface,
temperaturesensor,functionkeysanddisplay
PCD7.L663 wirelessreceiver
- - -
PCD7.L650 Interfacemoduletoconnectupto8oatingcontactsin
combinationwitharoomcontroller
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-2
3.1 TechnicalspecicationsofdigitalroomcontrolunitsPCD7.L640-.L644
RJ 9
Controller
PCD7.L670-xx
PCD7.L642
yellow
green
red
black
LED
comfort mode
Setpoint
potentiometer
temp.-sensor
Occupancy button
Occupancy button
RJ 9
Controller
PCD7.L670-xx
Set
Display
PCD7.L643
yellow
green
red
black
temp.-sensor
Occupancy button
HEVAC function
Pin allocation for PCD7.L640 - .L644
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerisdonewiththe
cablePCD7.L670-xxdirectlyonthecontrollerortheuse
ofexpansionmodulesforlightingandshadingonthelast
module.
Thepowercable,PCD7.L670-xx,isprefabricatedonboth
sidesandhasalengthofeither10,30or50m.
Themaximumlengthbetweentheroomcontrollerandthe
controlroomcontrolunitmustnotexceed50meters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-3
Functions for PCD7.L640 - .L644
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Depend-
ingontheroomcontrolunit,thesettingisenteredwitha
potentiometerorviatheintegrateddisplaywithHeaVAC
function.Thebasesetpointheldintheroomcontrollercan
beincreasedordecreasedinupto6steps.Thestepsize
isstoredintheroomcontrollerconguration.Seedescrip-
tionofCongFBoxorregisters(reg.104).
WhenthePlus,SetandMinuskeysarepressedtogether,
thecurrentsetpointisdisplayedforapprox.20seconds.
Presencesensor Thepresencesensorcanbeusedtochangetheoperat-
ingmodemanuallytoComfortorStandby/unused.Onthe
L640-L642controlunits,thepresencesensorlightsupin
Comfortmode.Ontheunitswithdisplays,theoperating
modeisshownonthedisplay.Thepersoniconoutside
thelittlehouseindicatesnon-use;ifthisiconisashing,
thecontrollerisinStandbymode.InComfortmode,the
personiconmovesintothehouse.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-4
3.1.1 TechnicaldataforPCD7.L640
RJ 9
Controller
PCD7.L670-xx
PCD7.L640
yellow
green
red
black
Setpoint
potentiometer
temp.-sensor
Roomcontrolunitwithtemperaturesensorandsetpointsetting.
Pinallocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Thesetting
isenteredviaapotentiometer.Therangeisconvertedinto
+/-6stepsandpassedtotheroomcontroller.Thebase
set point held in the room controller can be increased or
decreasedinsteps.Thestepsizeisstoredintheroom
controllerconguration.SeedescriptionofCongFBoxor
registers(reg.104).WhenthePlus,SetandMinuskeys
arepressedtogether,thecurrentsetpointisdisplayedfor
approx.20seconds.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-5
3.1.2 TechnicaldataforPCD7.L641
RJ 9
Controller
PCD7.L670-xx
PCD7.L641
yellow
green
red
black
LED
comfort mode
Setpoint
potentiometer
temp.-sensor
Occupancy button
Roomcontrolunitwithtemperaturesensor,setpointsettingandilluminatedpresence
sensor.
Pin allocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Thesetting
isenteredviaapotentiometer.Therangeisconvertedinto
+/-6stepsandpassedtotheroomcontroller.Thebase
set point held in the room controller can be increased or
decreasedinsteps.Thestepsizeisstoredintheroom
controllerconguration.SeedescriptionofCongFBoxor
registers(reg.104).WhenthePlus,SetandMinuskeys
arepressedtogether,thecurrentsetpointisdisplayedfor
approx.20seconds.
PresenceSensor Thepresencesensorcanbeusedtochangetheoperating
modemanuallytoComfortorStandby/unused.InComfort
mode,thesemi-transparentsensorlightsup.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-6
3.1.3 TechnicaldataforPCD7.L642
RJ 9
Controller
PCD7.L670-xx
PCD7.L642
yellow
green
red
black
LED
comfort mode
Setpoint
potentiometer
temp.-sensor
Occupancy button
Occupancy button
Roomcontrolunitwithtemperaturesensor,setpointsetting,illuminatedpresence
sensorandfancontrol.
Pin allocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Thesetting
isenteredviaapotentiometer.Therangeisconvertedinto
+/-6stepsandpassedtotheroomcontroller.Thebase
set point held in the room controller can be increased or
decreasedinsteps.Thestepsizeisstoredintheroom
controllerconguration.SeedescriptionofCongFBoxor
registers(reg.104).WhenthePlus,SetandMinuskeys
arepressedtogether,thecurrentsetpointisdisplayedfor
approx.20seconds.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-7
Function Description
PresenceSensor Thepresencesensorcanbeusedtochangetheoperating
modemanuallytoComfortorStandby/unused.InComfort
mode,thesemi-transparentsensorlightsup.
Fan control Thefanselectionswitchcanbeusedtosetthefanspeed
manually.Theroomcontrollercanonlyswitchtothe
desiredstepifthisisallowedbythefanoperatingwindow.
SeedescriptionofCongFBoxorregisters(reg.63,64)
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-8
3.1.4 TechnicaldataforPCD7.L643
RJ 9
Controller
PCD7.L670-xx
Set
Display
PCD7.L643
yellow
green
red
black
temp.-sensor
Occupancy button
HEVAC function
Roomcontrolunitwithtemperaturesensor,functionkeysanddisplayforHeaVAC
functions.
Pin allocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Setin+/-6
stepsviathedisplay.Thebasesetpointheldintheroom
controller can be increased or decreased in steps. The
stepsizeisstoredintheroomcontrollerconguration.
SeedescriptionofCongFBoxorregisters(reg.104).
WhenthePlus,SetandMinuskeysarepressedtogether,
thecurrentsetpointisdisplayedforapprox.20seconds.
Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859  ENG07 │ 2015-06-04
3
Digital room controller units
3-9
Function Description
PresenceSensor Thepresencesensorcanbeusedtochangetheoperat-
ingmodemanuallytoComfortorStandby/unused.The
operatingmodeisshowninthedisplay.Thepersonicon
outsidethelittlehouseindicatesnon-use;ifthisiconis
ashing,thecontrollerisinStandbymode.InComfort
mode,thepersoniconmovesintothehouse.
Fan control TheHeaVACmenucanbeusedtosetthefanspeed
manually.Theroomcontrollercanonlyswitchtothe
desiredstepifthisisallowedbythefanoperatingwindow.
SeedescriptionofCongFBoxorregisters(reg.63,64)
HeaVAC functions
ThedesiredfunctionisactivatedbypressingandholdingtheovalSETkey(for
approx.2seconds).Theactivefunctionisshowninthedisplaybytheashingicon.
Thesettingcanbechangedwiththeup/downarrowkeys.Ashortkeystrokeapplies
thecurrentsetting.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
/