BRB-100 — Principle of operation
The BRB-100 is a security device which en-
sures the presence of ventilation, of heating
and/or of a sufficient air intake in case of fail-
ure of the main ventilation system. The back-
up box uses the same outputs as the ones
used by the regular ventilation system. It has
2 different and independent security modes:
The first security mode is used in case of an
extreme room temperature; the second secu-
rity mode is used in case of power failure of
the main controller or relay panel.
1. Extreme room temperature: Up to 6 fans
(or heaters) can be activated if the tempera-
ture in the room exceeds the temperature set
point of T1, T2 or T3 thermostats. When the
room temperature reaches the set point of a
thermostat, the respective output is enabled:
(T1 thermostat activates K1 output, T2=K2,
T3=K3). Each thermostat can enable 2 fans
or heating outputs.
If the backup thermostat is used to ensure ven-
tilation, its set point must be greater than the
start temperature of the last fan stage of the
ventilation control; if it is used for heating, the
thermostat’s set point must be lower than the
start temperature of the last heating stage of
the ventilation control.
You must adjust the temperature
set point of the thermostats on
a regular basis according to the
changes made to the temperature
set point of the main ventilation control. You
must also test your mechanical thermostats at
the beginning of each flock or more often.
2. Power loss of the ventilation controller or
relay panel: If the ventilation stops due to a
power lost of the main ventilation controller or
of the relay panel, the backup box activates K5
and K6 fans (or heaters) and asks for an open-
ing of the K4 curtains or vent doors.
Backup Loads: The backup loads must be
connected to a dedicated circuit breaker. Do
not wire the backup loads on the same break-
er as the relay panel.
The relay selection of this diagram is shown
for illustration purpose only. The actual relay
selection has to be determined in the field
and wired as shown.
*Using a Thermostat Controller: A con-
troller can be used to replace mechanical
thermostats. Using this type of controller
changes the power supply connection of the
WIRING DIAGRAM
BRB-100
891-00104 Rev.07
BRB-100. It also changes the way actuators
and thermostat terminals are connected. If a
thermostat controller is used, refer its wiring
diagram to make the connections.
Installation Notes: Leave a clear-
ance of at least 12” to the left
of the controller’s box and 16”
to the left of the relay panel to
allow covers to be removed for
maintenance.
Technical Specifications:
Supply: 120Vac, 60Hz, 10A Max
Outputs: K1, K2, K3: 240Vac 15A, 240Vac 3HP
K4, K5, K6: 250Vac 10A, 250Vac 1HP
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
120/240 Vac
Fan Supply
BRB-100
Power Supply
120 Vac
The relay on which the
BRB-100 is connected must
always be turned on!
Relay Panel
BRB-100
(120 Vac)
5-Wire Actuator Wiring Diagram
5-Wire Actuator
3-Wire Actuator
120 Vac
Actuator
Power Supply
120 Vac
Actuator
Power Supply
To Ground
To Ground
Close
Close
Open
Open
L1 out
(Neutral)
Relay Panel
Relay Panel
BRB-100
BRB-100
3-Wire Actuator Wiring Diagram
120Vac
Thermostat
Power Supply
Thermostat 3*
Thermostat 2*
Thermostat 1*
REV.03
  • Page 1 1

Munters BRB Product information

Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI