ConsoliDator Multi-Channel Controlle
Instruction Manual
5
Display Preferences --------------------------------------------------------------------- 24
Decimal Point -------------------------------------------------------------------------- 24
Units -------------------------------------------------------------------------------------- 24
Bargraph -------------------------------------------------------------------------------- 24
Input Scaling & Math Functions ------------------------------------------------------- 25
Linear ------------------------------------------------------------------------------------ 25
Square Root ---------------------------------------------------------------------------- 26
Exponent -------------------------------------------------------------------------------- 27
Integration Mode ---------------------------------------------------------------------- 28
Fixed Value ----------------------------------------------------------------------------- 28
Summation & Difference ------------------------------------------------------------ 28
Multi-Point Linearization ------------------------------------------------------------- 29
Sensor Input Setup ----------------------------------------------------------------------- 29
Setting Flow Meter Pulse Inputs ------------------------------------------------------- 30
Display Parameters ---------------------------------------------------------------------- 30
Input Configuration Parameters ------------------------------------------------------- 30
Programming Relays ---------------------------------------------------------------------- 31
Supervisory or Summary Alarm Modes --------------------------------------------- 31
High or Low Alarm Modes -------------------------------------------------------------- 31
Multi-Channel High or Low Alarm Modes ------------------------------------------ 32
High or Low Pulse Alarm Modes ----------------------------------------------------- 33
Trigger Alarm Mode ---------------------------------------------------------------------- 34
Annunciator High or Low Alarm Modes --------------------------------------------- 34
Plunger Lift by Differential Pressure Mode ----------------------------------------- 35
Plunger Lift by Time Mode ------------------------------------------------------------- 35
Lead-Lag Modes (Pump Alternation Control) ------------------------------------- 36
Linear Pulse Width Modulation Mode ----------------------------------------------- 38
Proportional Plus Integral Pulse Width Modulation Mode ---------------------- 39
Setting 4-20 mA Outputs ----------------------------------------------------------------- 40
Linear Scaling of 4-20 mA Output ---------------------------------------------------- 40
PID Control Using 4-20 mA Output -------------------------------------------------- 40
OPERATION -------------------------------------------------------------------------- 41
Manual and Simulation Modes --------------------------------------------------------- 45
Contrast Adjustment Control ----------------------------------------------------------- 46
MODBUS
®
SERIAL COMMUNICATION --------------------------------------- 46
Modbus Register Tables ----------------------------------------------------------------- 47
CONSOLIDATOR MONITOR SOFTWARE ----------------------------------- 52
Connecting to PC --------------------------------------------------------------------------- 52
Installing Software ------------------------------------------------------------------------- 52
Using ConsoliDator Monitor Software ----------------------------------------------- 52
Data Logging ------------------------------------------------------------------------------ 53
Programming Through Software ------------------------------------------------------ 53
OVERALL DIMENSIONS ---------------------------------------------------------- 54
TROUBLESHOOTING TIPS ------------------------------------------------------ 55