Altronix HUBWAYLDH8 Installation guide

Category
AV equipment stands
Type
Installation guide
Rev. 032108
Active UTP Transceiver Hub
Installation Guide
Models Include:
HubWayLDH8 HubWayLDH16
- UL Listed eight (8) Camera Channels - UL Listed sixteen (16) Camera Channels
More than just power.
TM
Video Data
- 2 - HubWayLDH Active Hub Unit
Overview:
Altronix HubWayLDH8/16 Active UTP Transceiver Hub transmits UTP video and RS422/RS485 data over a single CAT-5
or higher structured cable. Unit provides 8 or 16 camera channels in a space saving 1U EIA 19” rack mount chassis which
may be rack, wall or shelf mounted. Video transmission range is up to 3000 ft. max. per channel. Units are compatible with
fixed or PTZ cameras. An optional HubSat4D Passive UTP Transceiver Hub with Integral Camera Power can be used as
an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the
HubWayLDH8/LDH16. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of
voltage drop associated with long cable runs.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes.
HubWayLDH Specifica tions:
Agency Listings:
• ULListedforCommercialCCTVEquipment(UL2044).
CUL Listed - CSA Standard C22.2 No.1-04, Audio,
VideoandSimilarEquipment.
• CEapproved.
Data:
• RS422/RS485datainputs.
Visual Indicators:
•ACinputpowerindicator.
•VideosignalLEDindicators.
Features:
• PictureandGaincontrol.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
• IEC320-3-wiregroundedlinecord(detachable).
• Unitcanberack,wallorshelfmounted.
• 1UrackmountchassisforuseinstandardEIA19”rack.
Accessories:
• OptionalHubSat4Dallowstransmissionofupto
four(4)videosignalsoverasingleCAT-5orhigher
structured cable.
HubWayLDH8
Input:
• 115VAC60Hz,1.5ampor
230VAC50/60Hz,1amp.
Video:
• Eight(8)channelsofvideoovertwistedpairupto
a distance of 3000 ft. per channel.
• Eight(8)75ohmvideooutputs.
HubWayLDH16
Input:
• 115VAC60Hz,3ampor
230VAC50/60Hz,1.5amp.
Video:
• Sixteen(16)channelsofvideoovertwistedpairupto
a distance of 3000 ft. per channel.
• Sixteen(16)75ohmvideooutputs.
Common Specifica tions:
HubWayLDH Active Hub Unit - 3 -
Installation Instructions:
1. SettheinputvoltageselectorswitchlocatedontheleftsideoftheHubWayLDH8/LDH16unit(facingfrontpanel)
for 115VAC or 230VAC operation (Fig. 1i, pg. 4).
2. Attach mounting brackets to HubWayLDH unit for rack or wall mount installation (Figs. 5-6, pg. 8). Affix rubber
pads to HubWayLDH for shelf installation (Fig. 7, pg. 8).
3. Securetheunitinarack,mountunittoawallorplaceunitonashelfasdesired(unitshouldbespacedatleast3”
fromanyvideomonitors).
4. Setilluminatedmasterpowerdisconnectcircuitbreakertothe(OFF)position(Fig. 4, pg. 7).
5. PlugthegroundedAClinecord(included)intotheIEC320connectoroftheHubWayLDH8/HubWayLDH16
unit (Fig. 1h, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.
6. ConnecttheBNCvideooutputsforHubWayLDH8/LDH16Channels1-8(Channels1-16)tothe
correspondingvideoinputsontheheadendequipment(DVR)(Fig. 1d, pg. 4).
7. ConnecttheRS422/RS485outputoftheheadendequipment(DVR)totheone(1)orbothdatainputterminal
blocksoftheHubWayLDH8orHubWayLDH16unit(polaritymustbeobserved)(Fig. 1c, pg. 4).
Note: The Data input terminals of the HubWayLDH8 or HubWayLDH16 must be wired in parallel for proper
operation. When using fixed cameras disregard this step.
8. ConnectVideoBalun/Combineratcamera1totheHubWayLDH8orHubWayLDH16unitutilizingCAT-5
or higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked
[Channel 1] of the HubWayLDH8/LDH16 (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the
structured cable into the RJ45 jack of the Video Balun/Combiner located at camera 1.
Repeatsteps6-9foreachadditionalcamera(Channels2-8orChannels2-16).
Note:Anexternalpowersourceisrequiredtopowerthecameras(Figs. 2-3, pgs. 5-6).Optionally,anAltronix
HubSat4DPassiveUTPTransceiverHubwithIntegralCameraPowermaybeutilized(Fig. 2a, pg. 5).
The combined total cable distance must not exceed 3000 ft. for video transmission between the
HubWayLDH8/LDH16 and each camera routed through the HubSat4D.
9. UponcompletionofthewiringsetilluminatedmasterpowerdisconnectcircuitbreakertotheRESET(ON)position
(Fig. 4, pg. 7).
10. ThevideosignalindicatorLEDs(Red)locatedontherearoftheHubWayLDH8/LDH16willilluminatewhen
video signal is present (Fig. 1g, pg. 4). If any of these LEDs are not illuminated, there is no video signal for
that corresponding channel.
11. Optimizethepicturequalityforallcamerachannelsbyadjustingthecorrespondingpotentiometers
marked [Picture] (Fig. 1e, pg. 4).
12. Setgainforallcamerachannelsbyadjustingthecorrespondingpotentiometersmarked[Gain](Fig. 1f, pg. 4).
- 4 - HubWayLDH Active Hub Unit
1234CH 1-4 CH 5-8
DATA
1-8
DATA
9-16
5678 9101112 CH 9-12 13 14 15 16 CH 13-16
AC POWER
16
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTUREGAINPICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN
15 14 13 12 11 10 987654 321
OFF
RESET
1a - Channels 1-8 (HubWayLD8)
or Channels 1-16 (HubWayLD16):
CAT-5 or higher structured cable to
Video/Balun Combiners at
cameras 1-8 or 1-16. When using
an optional HubSat4D any of the
outputscanbeutilizedforthedata
transmission to PTZ’s.
1d - BNC
Connector: Video
outputs to head end
equipment(DVR).
1b - Channels 1-4, Channels 5-8, Channels 9-12 & Channels 13-16:
CAT-5 or higher structured cable from optional HubSat4D enables
videotransmissionfromuptofour(4)cameras.
1g - LED(s) 1-16:
Video signal indicators.
1h - IEC 320 Connector:
115VAC60Hz/230VAC
50/60Hz(grounded
linecordincluded).
Fig. 1
1e - Picture:
Adjusts video
quality.
1f - Gain:
Regulates the
output video
and sync levels.
1c - Data: Removable
terminal blocks for RS422/
RS485 input from head end
equipment(DVR)forPTZcontrol.
+ --
Data input
from Head End
Equipment
(DVR).
Top View
1i - Input Voltage
Switch: Selects 115VAC
60Hz/230VAC50/60Hz
(switchislocatedontheleft
sideoftheunit).
115VAC 220VAC
Front
Rear
HubWayLDH Active Hub Unit - 5 -
115VAC
Input, 50/60Hz
Video
Video
Data
Power
Power
Power
Video
Power
HubWayDv/Dvi
Video Balun
Combiner
CAT- 5
CAT- 5
CAT- 5
12VDC
Fixed
Camera
HubWayAv
Video Balun
Combiner
24VAC
PTZ
Camera
Data
Video
Head End Equipment (DVR)
RS485
Video (Coax)
Four (4) Video
signals on a
single CAT- 5
Data
(CAT-5)
Power
24VAC
Fixed
Camera
HubWayDv/Dvi
Video Balun
Combiner
Video
Data
12VDC
PTZ
Camera
Power
Video
Data
Power
HubWayAv
Video Balun
Combiner
HubWayAv
Video Balun
Combiner
24VAC
Fixed
Camera
Max.
video
3000 ft.
24VAC
PTZ
Camera
Video
HubWayDv/Dvi
Video Balun
Combiner
CAT- 5
12VDC
Fixed
Camera
24VAC/28VAC
Camera Power
Provided
by HubSat4D
Video
Data
Power
24VAC
or 12VDC
Outdoor
NEMA
Rated
Power
Supply
Outdoor
24VAC
or
12VDC
PTZ
Camera
115VAC Input,
50/60Hz
HubWayAv or
HubWayDv/Dvi
Video Balun
Combiner
Monitor
Rear
Front
1234CH 1-4 CH 5-8
DATA
1-8
5678
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE
AC POWER
GAIN
87654321
Fig. 2
Typical Applications:
Fig. 2a - Optional hookup utilizing HubSat4D.
- 6 - HubWayLDH Active Hub Unit
Data
Video
Head End Equipment (DVR)
RS485
Monitor
Rear
Front
1234CH 1-4 CH 5-8
DATA
1-8
5678
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE
AC POWER
GAIN
87654321
Power
Power
Video
Power
Video
Data
Video Balun
Combiner
CAT- 5
Video Balun
Combiner
CAT- 5
12VDC or
24VAC
Fixed Camera
12VDC or
24VAC
Fixed Camera
12VDC or
24VAC
PTZ
Camera
12VDC or
24VAC
PTZ
Camera
Video
Power
Video Balun
Combiner
CAT- 5
External Rack Mount
12VDC or 24VAC Power Supply
115VAC Input,
50/60Hz
CAT- 5
Video Balun
Combiner
Power
Power
Video
Power
Video Balun
Combiner
CAT- 5
Video Balun
Combiner
CAT- 5
12VDC or
24VAC
Fixed Camera
12VDC or
24VAC
Fixed Camera
12VDC or
24VAC
PTZ
Camera
12VDC or
24VAC
PTZ
Camera
Video
Power
Video Balun
Combiner
CAT- 5
CAT- 5
Video Balun
Combiner
Video
Data
Video
Data
Video
Data
Max.
video
3000 ft.
Fig. 3
Typical Applications:
HubWayLDH Active Hub Unit - 7 -
(ON)
16
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE
AC POWER
GAIN
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
1 2 3 4 CH 1-4 CH 5-8
DATA
1-8
DATA
9-16
5 6 7 8 9 10 11 12 CH 9-12 13 14 15 16 CH 13-16
1.625"
41.28mm
17.625"
447.67mm
8.5"
215.9mm
0.75"
19.05mm
19.125"
485.78mm
Rack Mount Chassis Mechanical Drawing & Dimensions (H x W x D approximate):
1.625”x19.125”x8.5”(42mmx486mmx216mm)
TOP&BOTTOM
REAR
FRONT
Fig. 4
Illuminated master power disconnect circuit breaker:
• OFFpositionCircuitbreakertripped–Switchnotilluminated.
• RESET(ON)position–Switchilluminated.
Thelightningflashwitharrowheadsymbolwithinanequilateraltriangleisintendedtoalerttheusertothe
presenceofaninsulatedDANGEROUSVOLTAGEwithintheproduct’senclosurethatmaybeofsufficient
magnitude to constitute an electric shock.
Theexclamationpointwithinanequilateraltriangleisintendedtoalerttheusertothepresenceofimportant
operatingandmaintenance(servicing)instructionsintheliteratureaccompanyingtheappliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There
arenouserserviceablepartsinside.Referservicingtoqualifiedservicepersonnel.
- 8 - HubWayLDH Active Hub Unit
Altronix is not responsible for any typographical errors.
14058thStreet,Brooklyn,NewYork11220USA,718-567-8181,fax:718-567-9056
website:www.altronix.com,e-mail:[email protected],LifetimeWarranty,MadeinU.S.A.
IIHubWayLDH8/HubWayLDH16 E23N
MEMBER
Mounting Options:
Fig. 5
Wall Mount Installation
1-Installmountingbrackets(A)ontheleftandrightsideofrackchassis using
four(4)flatheadscrews(B)(included)(Fig. 6a).
2- Place unit at desired location and secure with mounting screws
(not included) (Fig. 6b).
Caution: It is necessary to
make sure mounting screws
are securely fastened to a
beam when installing the
unit vertically.
Rack Mount Installation
1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 5a).
2-Installmountingbrackets(A)ontheleftandrightsideofrackchassis using the
four(4)flatheadscrews(B)(included)(Fig. 5b).
3- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 5c).
Fig. 7
Fig. 6
Shelf Installation
1- Positionandaffixrubberpads(C)(included)ateach
corner on the bottom of the unit (Fig. 7).
2- Place unit in desired location.
B
A
C
Mounting Hardware (Included):
B
A
Fig. 6b
Fig. 6a
C
A
B
Fig. 5b
Fig. 5a
Fig. 5c
Top Top Top
Front
Left
Front
Left
FrontLeft
Left Side
Rubber Pad
Two(2)mountingbrackets
Six(6)flatheadscrews
for mounting brackets.
Four(4)rubberpads.
Remove
Dotted lines indicate studs
behind sheetrock.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Altronix HUBWAYLDH8 Installation guide

Category
AV equipment stands
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI