Electrolux 727086 (RCDR4M26U) Datasheet

Type
Datasheet
Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
D02-D04
CGX2006-13 (page 1 of 1), 2
nd
ed.
29 June 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Subject
“SEr” Parameter in UC/HT with CWS
Model
Undercounter LS6EA / WT38 and Hood Type LS14EA / WT65E with
Continuous Water Softener built-in.
Problem
Not working water softener after main board replacement (it seems the main
board resets SEr = 1 by itself).
Actions in
Field
Configuration parameters must be set following the sequence in the relevant
programming sheet (available in the service manual).
Therefore the parameter SEr must be set = 9 after having set all remaining
parameters and switched the machine off/on, otherwise the “dFL” sets the
main board as for a machine without water softener.
Example for Undercounter: set CFG parameters as first
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
Switch the machine OFF/ON Then set SEr = 9
Switch to the next parameter (“Adr”) then switch the machine OFF/ON.