GW Instek GBS-1000 Programming User manual

Type
User manual
Digital Storage Oscilloscope
GBS-1000 Series
PROGRAMMING MANUAL
GW INSTEK PART NO. 82BS-12040M01
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by
copyrights. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan.
TABLE OF CONTENTS
3
Table of Contents
CONFIGURATION ............................................................. 4
Interface Overview ................................. 5
USB interface Configuration................... 7
RS-232C Interface Configuration ............ 8
COMMAND SET .............................................................. 11
COMMAND SET .............................................................. 11
Command List ..................................... 11
Command Syntax ................................. 16
System Commands .............................. 17
Acquisition Command .......................... 20
Auto Set Command .............................. 23
Channel / Math Command ................... 24
Data Log Commands ........................... 30
Cursor Command ................................. 33
Display Command ................................ 36
Go-NoGo Command ............................ 39
Hardcopy Command ............................ 50
Measure command .............................. 53
Memory (Save/Recall) Command ......... 70
Run/Stop Commands ........................... 77
Trigger Commands ............................... 78
Time (horizontal) Commands .............. 86
GBS-1000 Programming Manual
4
CONFIGURATION
This chapter describes how to configure GBS-1000
remote control interface.
GBS-1000 series
overview
Interface Overview ....................................... 5
Rear panel ...................................................................... 5
Interface type ................................................................. 5
USB interface Configuration ........................ 7
RS-232C Interface Configuration .................. 8
CONFIGURATION
5
Interface Overview
Rear panel
Power
socket
Fuse
socket
RS232C
port
USB Slave
Connector
Power
switch
Calibration Output
Terminal
GO-NoGO Output
Terminal
USB Host
Connector
Interface type
Terminal
application
(USB/RS-232C)
Invoke the terminal application such as MTTTY
(Multi-Threaded TTY).
For USB, set the COM port to COM7. No other
setting is required.
For RS-232C, set the COM port, baud rate, stop
bit, data bit, and parity accordingly.
To check the COM port No. for RS-232C, see the
Device Manager in the PC. For WinXP, Control
panel → System → Hardware tab.
GBS-1000 Programming Manual
6
Functionality
check
Run this query command via the terminal.
*idn?
This should return the Manufacturer, Model
number, Serial number, and Firmware version in
the following format.
GW, GBS-1064, 000000001, V1.00
PC Software
(USB only)
The PC software, FreeWave, can be used for
remote control. This mode is only available for the
USB interface.
1. Activate FreeWave. For
installation details, see page
the FreeWave user manual.
CONFIGURATION
7
USB interface Configuration
USB
configuration
PC side connector
Type A, host
GBS-1000 side
connector
Type B, slave
Speed
1.1/2.0 (full speed)
Panel operation
1. Press the Utility key.
Utility
2. Press F2 (Interface Menu).
Interface
Menu F 2
3. Press F1 (Type) repeatedly
to select USB.
Type
USB F 1
4. The interface icon at the top
of the display changes into
USB type.
5. Connect the USB cable to
the rear panel slave port.
6. When the PC asks for the USB driver, select
dso_vpo.inf included on the User Manual CD
or in the FreeWave software package
downloadable from GW website,
www.gwinstek.com.tw, GBS-1000 product
corner.
GBS-1000 Programming Manual
8
RS-232C Interface Configuration
RS-232C
configuration
Connector
DB-9, Male
Baud rate
2400, 4800, 9600, 19200, 38400
Parity
None, Odd, Even
Data bit
8 (fixed)
Stop bit
1, 2
Panel operation
1. Press the Utility key.
Utility
2. Press F2 (Interface Menu).
Interface
Menu F 2
3. Press F1 (Type) repeatedly
to select RS-232C.
Type
RS232 F 1
4. The interface icon at the top
of the display changes into
RS-232C type.
5. To change the baud rate,
press F2 (Baud Rate)
repeatedly.
Baud Rate
9600 F 2
Range
2400, 4800, 9600, 19200, 38400
6. To change the stop bit, press
F3 (Stop Bit) repeatedly.
Stop Bit
2F 3
Range
1, 2
7. Data bit is fixed at 8.
8. To change the parity, press
F4 (Parity) repeatedly.
Parity
None F 4
CONFIGURATION
9
Range
None, Odd, Even
9. Connect the RS-232C cable
to the rear panel port: DB-9
male connector.

Pin assignment
1 2 3 4 5
6 7 8 9
2: RxD (Receive data)
3: TxD (Transmit data)
5: GND
4, 6 ~ 9: No connection
PC connection
Use the Null Modem connection as in the below
diagram.
GBS
-
1000
PC
TxD
RxD
GND
Pin
2
Pin
3
Pin
5
RxD
TxD
GND
Pin
2
Pin
3
Pin
5
GBS-1000 Programming Manual
10
COMMAND SET
11
COMMAND SET
Command List
System
*IDN?.......... .................................................................17
*LRN?............ ...............................................................17
*RCL………. ...................................................................19
*RST………. ...................................................................19
*SAV……… ....................................................................19
Acquisition
:ACQuire:AVERage ...................................................... 20
:ACQuire:LENGth ........................................................21
:ACQuire:MODe ..........................................................21
:ACQuire:MEMory ...................................................... 22
:ACQuire:HORexpand ................................................ 22
Channel / Math
:CHANnel<X>:BWLimit .............................................. 24
:CHANnel<X>:COUPling ............................................ 25
:CHANnel<X>:DISPlay ............................................... 25
:CHANnel<X>:EXPand ............................................... 26
:CHANnel<X>:INVert ................................................. 26
:CHANnel<X>:MATH ................................................. 27
:CHANnel<X>:OFFSet ................................................ 28
:CHANnel<X>:PROBe ................................................ 28
:CHANnel<X>:SCALe ................................................. 29
Data Log
:DATALOG:STATE ...................................................... 30
:DATALOG:SOURce ................................................... 30
:DATALOG:SAVe .........................................................31
:DATALOG:INTerval ....................................................31
:DATALOG:DURation ..................................................31
GBS-1000 Programming Manual
12
Display
:DISPlay:ACCumulate .................................................. 36
:DISPlay:CONTrast ...................................................... 37
:DISPlay:GRATicule ..................................................... 37
:DISPlay:WAVEform .................................................... 38
:REFResh ...................................................................... 38
Go-NoGo
:GONogo:FUNction .................................................... 39
:GONogo:CLEar ........................................................... 40
:GONogo:EXECute ...................................................... 40
:GONogo:NGCount? ................................................... 41
:GONogo:NGDefine .................................................... 41
:GONogo:SOURce ...................................................... 42
:GONogo:VIOLation ................................................... 42
:TEMPlate:MAX ........................................................... 43
:TEMPlate:MIN ............................................................ 44
:TEMPlate:MODe ........................................................ 45
:TEMPlate:POSition:MAX ............................................ 46
:TEMPlate:POSition:MIN ............................................ 47
:TEMPlate:SAVe:AUTo................................................. 48
:TEMPlate:SAVe:MAXimum ........................................ 48
:TEMPlate:SAVe:MINimum ........................................ 48
:TEMPlate:TOLerance .................................................. 49
Hardcopy
:COPY…… ..................................................................... 50
:HARDcopy:INKSaver .................................................. 50
:HARDcopy:LAYout ..................................................... 51
:HARDcopy:MODe ...................................................... 51
:HARDcopy:RATio ....................................................... 52
COMMAND SET
13
Measure
:MEASure:DELAY1 ...................................................... 54
:MEASure:DELAY2 ...................................................... 55
:MEASure:FALL ........................................................... 55
:MEASure:FFFDelay .................................................... 56
:MEASure:FFRDelay .................................................... 56
:MEASure:FOVShoot .................................................. 57
:MEASure:FPReshoot ................................................. 57
:MEASure:FREQuency? .............................................. 58
:MEASure:FRFDelay .................................................... 58
:MEASure:FRRDelay ................................................... 59
:MEASure:LFFDelay .................................................... 59
:MEASure:LFRDelay .................................................... 60
:MEASure:LRFDelay .................................................... 60
:MEASure:LRRDelay ....................................................61
:MEASure:NWIDth ......................................................61
:MEASure:PDUTy? ...................................................... 62
:MEASure:PERiod? ...................................................... 62
:MEASure:PWIDth? .................................................... 63
:MEASure:RISe? .......................................................... 63
:MEASure:ROVShoot .................................................. 64
:MEASure:RPReShoot ................................................. 64
:MEASure:SOURce ..................................................... 65
:MEASure:VAMPlitude ............................................... 65
:MEASure:VAVerage ................................................... 66
:MEASure:VHI ............................................................. 66
:MEASure:VLO ............................................................ 67
:MEASure:VMAX ......................................................... 67
:MEASure:VMAX ......................................................... 68
:MEASure:VMIN ......................................................... 68
:MEASure:VPP ............................................................ 69
:MEASure:VRMS ......................................................... 69
GBS-1000 Programming Manual
14
Memory
:MEMory<X>:RECall:SETup ........................................ 70
:MEMory<X>:RECall:WAVeform ................................. 71
:MEMory<X>:SAVe:SETup .......................................... 71
:MEMory<X>:SAVe:WAVeform ................................... 72
:REFResh ...................................................................... 72
:REF<X>:DISPlay ......................................................... 72
:REF<X>:LOCate .......................................................... 73
:REF<X>:SAVe .............................................................. 74
:USB:RECall:SETup ...................................................... 74
:USB:RECall:WAVeform ............................................... 75
:USB:SAVe:ALL ............................................................ 75
:USB:SAVe:IMAGe ....................................................... 75
:USB:SAVe:SETup ........................................................ 76
:USB:SAVe:WAVeform ................................................. 76
Run/Stop
:RUN………. .................................................................. 77
:STOP….. ...................................................................... 77
Trigger
:TRIGger:COUPle ......................................................... 78
:TRIGger:FREQuency ................................................... 79
:TRIGger:LEVel ............................................................. 79
:TRIGger:MODe ........................................................... 79
:TRIGger:NREJ ............................................................. 80
:TRIGger:PULSe:MODe ............................................... 80
:TRIGger:PULSe:TIMe ................................................. 81
:TRIGger:REJect ........................................................... 81
:TRIGger:SLOPe ........................................................... 82
:TRIGger:SOURce ........................................................ 82
:TRIGger:TYPe ............................................................. 83
:TRIGger:VIDeo:FIELd ................................................. 83
:TRIGger:VIDeo:LINe .................................................. 84
:TRIGger:VIDeo:POLarity ............................................ 84
:TRIGger:VIDeo:TYPe .................................................. 85
COMMAND SET
15
Time
:TIMebase:DELay ........................................................ 86
:TIMebase:SCALe ........................................................ 86
:TIMebase:SWEep ....................................................... 87
:TIMebase:WINDow:DELay ........................................ 88
:TIMebase:WINDow:SCALe ....................................... 88
GBS-1000 Programming Manual
16
Command Syntax
Compatible
standard
IEEE488.2, 1992 (fully compatible)
SCPI, 1994 (partially compatible)
Command format
trig:del:mod <NR1>LF
1 2 3 4
1: command header
2: single space
3: parameter
4: message terminator
Parameter
Type
Description
Example
<Boolean>
boolean logic
0, 1
<NR1>
integers
0, 1, 2, 3
<NR2>
decimal numbers
0.1, 3.14, 8.5
<NR3>
floating point
4.5e-1, 8.25e+1
<NRf>
any of NR1, 2, 3
1, 1.5, 4.5e-1
Message
terminator
Terminates a command line.
LF^END
line feed code (hexadecimal 0A)
with END message
LF
line feed code
<dab>^END
last data byte with END message
Note
Commands introduced here are described in
abbreviated style (same functionality)
Commands are non-case sensitive.
COMMAND SET
17
System Commands
*IDN?...........................................................................17
*LRN?.................. .........................................................17
*RCL………………….. ......................................................19
*RST…………. ................................................................19
*SAV………... .................................................................19
*IDN?
Set
Query
Description
Returns oscilloscope ID as Manufacturer, Model
No, Serial No, Firmware version.
Syntax
*idn?
Return parameter
<string>
Scope id
Example
*idn?
> GW,GBS-1062,
ZZ1234567891,V1.00
BXXXX_1
Returns the scope id.
*LRN?
Set
Query
Description
Returns the oscilloscope settings as a string
Syntax
*lrn?
Return parameter
<string>
scope settings
Example
*lrn?
>:SYSTem:TIMe 13 47 4;DATe 16 12
2013;:TRIGger:TYPe 0;COUPle 0;LEVel
0.000E+00;MODe 1;NREJ 0;REJect 0;SLOP
GBS-1000 Programming Manual
18
0;SOURce 0;ADVance:DELay 1.000E-07;EVENt
3;LEVel 1.480E+00;MODe 0;TYPe 0;PULSe:TIMe
1.000E+01;MODe: 1;TV:FIELd 1;LINe 1;POLarity
1;TYPe 0;:ACQuire:AVERage 1;LENGth
12500;MODe 0;POINt;:DISPlay:WAVeform
0;DISPCONTrast 4;GRATicule 0;:CURSor:SOURce
1;X1Position ;X2Position ;Y1Position
;Y2Position ;XDELTa ;YDELTa ;X
DISPlay 2;YDISPlay 2;:CHANnel1:BWLimit
0;COUPling 1;DISPlay 1;INVert 0;MATH 0;OFFSet
1.000e-01;PROBe 0;SCALe 1.000e-
01;:CHANnel2:BWLimit 0;COUPling 0;DISPlay
1;INVert 0;MATH 0;OFFSet 2.080e-01;PROBe
0;SCALe 2.000e-01;:MEASure:SOURce 1;FALL
1.563E-06;FREQuency 1.000E+03;NWIDth 4.999E-
04;PDUTy 50.00%;PERiod 1.000E-03;PWIDth
5.000E-04;RISe 1.030E-06;VAMPlitude 2.280E-
01;VAVerage 2.370E-03;VHI 1.160E-01;VLO -
1.120E-01;VMAX 1.160E-01;VMIN -1.120E-01;VPP
2.280E-01;VRMS 1.000E-01;ROVShoot
0.00%;FOVShoot ?;RPReshoot ?;FPReshoot
0.00%;:MEASure:SOURce
2;FALL ?;FREQuency ?;NWIDth ?;PDUTy ?;PERio
d ?;PWIDth ?;RISe ?;VAMPlitude 4.000E-
02;VAVerage 1.720E-02;VHI 4.000E-02;VLO
0.000E+00;VMAX 4.000E-02;VMIN 0.000E+00;VPP
4.000E-02;VRMS 1.820E-
02;ROVShoot ?;FOVShoot ?;RPReshoot ?;FPReshoo
t ?;DELAY1 1;DELAY2 2;FRRDelay -1.487E-
05;FRFDelay -1.487E-05;FFRDelay -5.149E-
04;FFFDelay -5.149E-
04;LRRDelay ?;LRFDelay ?;LFRDelay ?;LFFDelay ?
;:TIMebase:DELay 0.000e+00;SCALe 2.500e-04;
SWEep 0;:AUToset;:PRINt;:REFResh;:RUN;:STOP
COMMAND SET
19
*RCL
Set
Description
Recalls a set of panel setting from one of the
twenty internal memories, S1 to S20.
Same as: Save/Recall key → F5(More) → F3(Recall
Setup)
Syntax
*rcl <NR1>
Parameter
<NR1>
Settings
1 to 20
S1 to S20
Example
*rcl 1
Recalls the panel settings
from S1
*RST
Set
Description
Resets the GDB-1000 (recalls the default panel
settings).
Same as: Save/Recall key → F1(Default Setup)
Syntax
*rst
*SAV
Set
Description
Saves the panel setting to one of the twenty
internal memories, S1 to S20.
Same as: Save/Recall key → F3(Save Setup)
Syntax
*sav<NR1>
Parameter
<NR1>
Settings
1 to 20
S1 to S20
Example
*SAV 1
Saves the panel settings
to S1.
GBS-1000 Programming Manual
20
Acquisition Command
:ACQuire:AVERage ...................................................... 20
:ACQuire:LENGth ........................................................ 21
:ACQuire:MODe .......................................................... 21
:ACQuire:MEMory ....................................................... 22
:ACQuire:HORexpand ................................................. 22
:ACQuire:AVERage
Set
Query
Description
Selects or returns the average number of waveform
acquisition in average acquisition mode.
Same as: Acquire key → F3
Syntax
< Long >
< Short >
:acquire:average <NR1>
:acquire:average?
:acq:aver <NR1>
:acq:aver?
Parameter
<NR1>
Average No
<NR1>
Average No
1
2
5
32
2
4
6
64
3
8
7
128
4
16
8
256
Before this
command
Before selecting the average number, select the
average acquisition mode using this command.
:ACQuire:MODe 2
Example
:acquire:mode 2
:acquire:average 2
Set the acquisition mode
to average, then set the
average number to 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

GW Instek GBS-1000 Programming User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI