SPLIT AIR CONDITIONER
INSTALLATION MANUAL
(PART No. 9332809046-02)
R410A
REFRIGERANT
This Air Conditioner contains and operates
with refrigerant R410A.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
This air conditioner uses new refrigerant HFC (R410A).
The basic installation work procedures are the same as conventional refrigerant (R22) models.
However, pay careful attention to the following points:
(1) Since the working pressure is 1.6 times higher than that of conventional refrigerant (R22) models, some of the piping and installation
and service tools are special. (See the table below.)
Especially, when replacing a conventional refrigerant (R22) model with a new refrigerant R410A model, always replace the conventional
piping and fl are nuts with the R410A piping and fl are nuts.
(2) Models that use refrigerant R410A have a different charging port thread diameter to prevent erroneous charging with conventional re-
frigerant (R22) and for safety. Therefore, check beforehand. [The charging port thread diameter for R410A is 1/2 threads per inch.]
(3) Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with refrigerant (R22) models. Also, when storing the
piping, securely seal the opening by pinching, taping, etc.
(4) When charging the refrigerant, take into account the slight change in the composition of the gas and liquid phases, and always charge
from the liquid phase side whose composition is stable.
Special tools for R410A
Tool name Contents of change
Gauge manifold
Pressure is high and cannot be measured with a conventional gauge. To prevent erroneous mixing of other refrigerants, the
diameter of each port has been changed.
It is recommended the gauge with seals-0.1 to 5.3 MPa (-1 to 53 bar) for high pressure.
-0.1 to 3.8 MPa (-1 to 38 bar) for low pressure.
Charge hose
To increase pressure resistance, the hose material and base size were changed.
Vacuum pump
A conventional vacuum pump can be used by installing a vacuum pump adapter.
Gas leakage detector
Special gas leakage detector for HFC refrigerant R410A.
Copper pipes
It is necessary to use seamless copper pipes and it is desirable that the amount of residual
oil is less than 40 mg/10 m. Do not use copper pipes having a collapsed, deformed or
discolored portion (especially on the interior surface). Otherwise, the expansion value or
capillary tube may become blocked with contaminants.
As an air conditioner using R410A incurs pressure higher than when using R22, it is
necessary to choose adequate materials.
Thicknesses of copper pipes used with R410A are as shown in Table.
Never use copper pipes thinner than that in the table even when it is available on the market.
Thicknesses of Annealed Copper Pipes
Thickness (mm)
Nominal
diameter (in.)
Outer diameter
(mm)
R410A [ref.] R22
1/4 6.35 0.80 0.80
1/2 12.70 0.80 0.80
WARNING
Do not use the existing (for R22) piping and fl are nuts.
• If the existing materials are used, the pressure inside the refrigerant cycle will rise and cause breakage, injury, etc. (Use the special R410A materials.)
When installing and relocating the air conditioner, do not mix gases other than the specifi ed refrigerant (R410A) to enter the refrigerant cycle.
• If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to an abnormally high value and cause breakage, injury, etc.
For authorized service personnel only.
WARNING
For the room air conditioner to operate satisfactory, install it as outlined in this installation manual.
Connect the indoor unit and outdoor unit with the air conditioner piping and cables available standards parts. This installation manual describes the correct
connections using the standard accessories and the parts specifi ed in this installation manual.
Have installation work done by authorized service personnel only.
Do not use this equipment with air or any other unspecifi ed refrigerant in the refrigerant lines. Excess pressure can cause a rupture.
Do not use an extension cable.
Do not turn on the power until all installation work is complete.
• Be careful not to scratch the air conditioner when handling it.
• After installation, explain correct operation to the customer, using the operating manual.
• Let the customer keep this installation manual because it is used when the air conditioner is serviced or moved.
• The maximum length of the piping is 30 m. The minimum length of the piping is 5 m. The maximum height difference of the piping is 20 m.
• If the units are further apart than these, correct operation can not be guaranteed.
Tapping screw
Hooks
Connector cover
Tapping screw
OUTDOOR UNIT INSTALLATION
OPERATING
RANGE
WARNING
Install the unit where it will not be tilted by more than 5°.
When installing the outdoor unit where it may exposed to strong wind, fasten it securely.
Outdoor temperature
Cooling Mode
Dry Mode
About -10 to 46°C
Heating Mode About -15 to 24°C
POWER
WARNING
The rated voltage of this product is 240 V AC 50 Hz. Use a circuit breaker and receptacle matched to the capacity of the air
conditioner.
Do not extend the power cable.
Before turning on the power, check if the voltage is within the
220 V -10 % to 240 V +10 % range.
Perform wiring work in accordance with standards so that the air conditioner
can be operated safely and positively.
Always use a special branch circuit and install a special receptacle to
supply power to the room air conditioner.
Install a leakage circuit breaker in accordance with the related laws and
regulations and electric company standards.
CAUTION
The power source capacity must be the sum of the air conditioner current and the current of other electrical appliances. When the current contracted ca-
pacity is insuffi cient, change the contracted capacity.
When the voltage is low and the air conditioner is diffi cult to start, contact the power company the voltage raised.
ELECTRICAL REQUIREMENT
• Install all electrical works in accordance to the
national standard.
• Install the disconnect device with a contact
gap of at least 3 mm in all poles nearby the
units. (Both indoor unit and outdoor unit)
• Install the circuit breaker nearby the units.
• Electric wire size and breaker capacity:
Cable Conductor size [mm
2
] Type Remarks
Power supply cable 4.0
Type 60245
IEC 57
2Cable+Earth(Ground),1φ240V
Connection cable 1.5 3Cable+Earth(Ground),1φ240V
Installation instruction on the back.
Decide the mounting position with the customer as follows:
(1) If possible, do not install the unit where it will be exposed to direct sunlight. (If necessary, install a blind that
does not interfere with the air fl ow.)
(2) Do not install the unit where a strong wind blows or where it is very dusty.
(3) Do not install the unit where people pass.
(4) Take your neighbors into consideration so that they are not disturbed by air blowing into their windows or by
noise.
(5) Provide the space shown in the fi gure so that the air fl ow is not blocked. Also for effi cient operation, leave
open three of the four directions front, rear, and both sides.
WARNING
Install at a place that can withstand the weight of the outdoor units and install positively so that the units will
not topple or fall.
CAUTION
Do not install the outdoor unit in the following areas:
• Area with high salt content, such as at the seaside. It will deteriorate metal parts, causing the parts to fail or
the unit to leak water.
• Area fi lled with mineral oil or containing a large amount of splashed oil or steam. It will deteriorate plastic
parts, causing the parts to fail or the unit to leak water.
• Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine gas,
acid, or alkali. It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant leakage.
• Area containing equipment that generates electromagnetic interference. It will cause the control system to
malfunction, preventing the unit from operating normally.
• Area that can cause combustible gas to leak, contains suspended carbon fi bers or fl ammable dust, or volatile
infl ammables such as paint thinner or gasoline. If gas leaks and settles around the unit, it can cause a fi re.
• Area that has heat sources, vapors, or the risk of the leakage of fl ammable gas in the vicinity.
• Area where small animals may live. It may cause failure, smoke or fi re if small animals enter and touch
internal electrical parts.
• Area where animals may urinate on the unit or ammonia may be generated.
When the outdoor temperature is 0°C or less, do not use the accessory drain pipe . If the drain pipe are
used, the drain water in the pipe may freeze in extremely cold weather.
Do not place any other electrical products or household belongings under indoor unit or outdoor unit. Dripping
condensation from the unit might get them wet, and may cause damage or malfunction of your property.
If children under 10 years old may approach the unit, take preventive measures so that they cannot reach
the unit.
Do not touch the aluminum fi ns of heat exchanger built-in the indoor or outdoor unit to avoid personal injury
when you install or maintain the unit.
In the area with heavy snowfall, if the intake and outlet of outdoor units blocked with snow, it might become
diffi cult to get warm and it is likely to cause of the breakdown.
Please construct a canopy and a ped-estal or place the unit on a high stand (local confi gured).
SELECTING THE MOUNTING POSITION
54 cm
32 cm
INSTALLATION
DIAGRAM
INDOOR UNIT
[OUTDOOR UNIT]
10 cm
or over
60 cm or over
10 cm or over
20 cm
or over
25 cm
or over
5 cm or over
OUTDOOR UNIT ACCESSORIES
Drain pipe
1
Drain cap
3
● Set the unit on a strong stand such as thing made of concrete blocks to
minimize shock and vibration.
● Do not set the unit directly on the ground because it will cause trouble.
Connector cover removal
• Remove the tapping screws.
Installing the connector cover
(1) After inserting the four hooks, then slide the cover.
(2) Tighten the tapping screws.
Outdoor
unit
bottom
Drain
pipe
Drain cap
Drain cap
Breaker
capacity
25(A)