Molex SST-PB3S-CLXT-RLL User Reference Manual

Type
User Reference Manual

This manual is also suitable for

SST-PB3S-CLX-RLL
User Reference Guide
Document Edition:1.0
Document #:715-0109
User Reference Guide SST-PB3S-CLX-RLL
ii
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Document Edition:
Date: May 14, 2014
This document applies to the SST-PB3S-CLX-RLL, SST-PB3S-CLX-RLL-CC,
SST-PB3S-CLXT-RLL, Profibus slave modules.
Copyright ©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
This document and its contents are the proprietary and confidential property of Molex Inc. and/or
its related companies and may not be used or disclosed to others without the express prior written
consent of Molex Inc. and/or its related companies.
SST is a trademark of Molex Inc. All other trademarks belong to their respective companies.
At Molex, we strive to ensure accuracy in our documentation. However, due to rapidly evolving
products, software or hardware changes occasionally may not be reflected in our documents. If
you notice any inaccuracies, please contact us (see Appendix C).
Written and designed at:
Molex Incorporated
216 Bathurst Drive
Waterloo, Ontario, Canada N2V 2L7
Hardcopies are not controlled.
SST-PB3S-CLX-RLL User Reference Guide
Contents iii
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Contents
Preface ........................................................................................................................... v
Purpose of this Guide ................................................................................................................. vi
Special Notation ......................................................................................................................... vi
System Overview........................................................................................................... 7
1.1 System Overview ................................................................................................................8
1.1.1 Slave Capabilities .............................................................................................................8
1.1.2 Operating Modes ..............................................................................................................9
Hardware Overview ..................................................................................................... 11
2.1 Hardware Features ............................................................................................................12
2.1.1 Status LEDs ....................................................................................................................13
2.1.2 9-Pin PROFIBUS Connector .........................................................................................13
2.1.3 Configuration Port ..........................................................................................................13
Quick Start ................................................................................................................... 15
3.1 Purpose .............................................................................................................................16
3.2 Equipment and Tools ........................................................................................................16
3.3 Package Contents ..............................................................................................................16
3.4 Power Requirements .........................................................................................................17
3.5 Procedures ........................................................................................................................17
3.5.1 Setting up the Slave Module ..........................................................................................17
3.5.2 Getting the Slave Module Running ................................................................................18
User Reference Guide SST-PB3S-CLX-RLL
iv Contents
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Installing the SST-PB3S-CLX-RLL Slave ................................................................... 21
4.1 Installing the Slave Module ..............................................................................................22
4.1.1 Installation Procedure .....................................................................................................22
4.1.2 Removal Procedure ........................................................................................................22
4.2 PROFIBUS Wiring ...........................................................................................................23
4.2.1 Selecting the Proper Line Type ......................................................................................24
4.2.2 PROFIBUS Connector ...................................................................................................25
4.3 PROFIBUS LED and Display States................................................................................26
4.4 LED and Display Combinations .......................................................................................27
4.5.1 Display Tables ................................................................................................................28
System Diagnostics .................................................................................................... 29
5.1 PB3S Status Register ........................................................................................................30
5.2 Slave Firmware Version ...................................................................................................30
5.3 Diagnostic Counters .........................................................................................................31
Slave Functionality ...................................................................................................... 33
6.1 Slave I/O interface ............................................................................................................34
6.1.2 Interface Image for Add-On-Profile ..................................................................................34
6.1.3 Interface Image for Generic Profile ...............................................................................35
6.2 Register Definitions and Layout .......................................................................................37
6.2.1 DP Slave Status Table Entries ........................................................................................37
6.3 I/O Table Additions/Modifications ..................................................................................39
6.4 Config Table Additions ....................................................................................................39
6.5 Slave Configuration and Programming ............................................................................41
6.5.1 Configuring the CLX Slave in RSLogix 5000 using Generic Profile ............................42
6.5.2 Configuring the CLX Slave in RSLogix 5000 using Add-on-Profile (AOP) ................45
Technical Specifications ............................................................................................ 49
A.1 Technical Specifications ...................................................................................................50
Regulatory Compliance .............................................................................................. 51
B.1 CE Compliance .................................................................................................................52
B.2 Rep. of Korea Compliance ...............................................................................................53
Warranty and Support ................................................................................................. 55
C.1 Warranty ...........................................................................................................................56
C.2 Reference Documents .......................................................................................................56
C.3 Technical Support .............................................................................................................57
C.4 Getting Help .....................................................................................................................57
SST-PB3S-CLX-RLL User Reference Guide
Preface v
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Preface
Preface Sections:
Purpose of this Guide
Special Notation
User Reference Guide SST-PB3S-CLX-RLL
vi Preface
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Purpose of this Guide
This manual is a user's guide for the SST ControlLogix (CLX) PROFIBUS slave module series,
SST-PB3S-CLX-RLL, SST-PB3S-CLX-RLL-CC, SST-PB3S-CLXT-RLL and will be
generically referred throughout this guide as the SST-PB3S-CLX-RLL. Use this guide if you are
responsible for installing, programming or troubleshooting control systems that use Allen-
Bradley CLX processors and the SST-PB3S-CLX-RLL slave module series. It is assumed that
you have a basic understanding of PLCs and are familiar with PROFIBUS modules and the
PROFIBUS network.
Special Notation
The following special notations are used throughout this guide:
Warning
Warning messages alert the reader to situations where personal injury
may result. Warnings are accompanied by the symbol shown, and
precede the topic to which they refer.
Caution
Caution messages alert the reader to situations where equipment damage
may result. Cautions are accompanied by the symbol shown, and
precede the topic to which they refer.
Note
A note provides additional information, emphasizes a point, or gives a
tip for easier operation. Notes are accompanied by the symbol shown,
and follow the text to which they refer.
SST-PB3S-CLX-RLL User Reference Guide
System Overview 7
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
1
System Overview
Chapter Sections:
System Overview
User Reference Guide SST-PB3S-CLX-RLL
8 System Overview
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
1.1 System Overview
1.1.1 Slave Capabilities
The SST-PB3S-CLX-RLL is a PROFIBUS slave-only interface for the 1756 (ControlLogix)
backplane system. It enables communication between a CLX processor and Profibus slave
device on a PROFIBUS network. The module:
Supports standard ControlLogix or ControlLogix XT platforms
Supports Rockwell’s RSLogix 5000 Add-on-Profile (AOP)
Supports a range of 1-122 words of input data and 1-122 words of output data per slave
module for a maximum of 244 words data exchange
Can reside in any slot in the local or remote CLX chassis.
Supports all standard PROFIBUS baud rates (9600, 19200, 45.45k, 93.75k, 187.5k, 500k,
1.5M, 3M, 6M, 12M)
Acts as a DP-V0 slave interface
Supports: Profibus repeaters in the network, data swapping, Auto-Run mode, legacy
device ID, diagnostic LEDs and front-of-module scrolling LCD display
Does not require ladder logic in the CLX to transfer data or configuration setup
Direct module swap-out for quick module replacement
Can be a drop-in replacement for Legacy SST-PFB-CLX module that is only configured
as a slave (using Profibus ID 0x0876)
Slave configuration via the ControlLogix configuration file
Slave configuration via AOP interface which updates the configuration file automatically
SST-PB3S-CLX-RLL User Reference Guide
System Overview 9
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Slave Module Versions:
1.1.2 Operating Modes
The SST-PB3S-CLX operates in Asynchronous Mode to backplane RPI (Requested Packet
Interval).
User Reference Guide SST-PB3S-CLX-RLL
10 System Overview
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
SST-PB3S-CLX-RLL User Reference Guide
Hardware Overview 11
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
2
Hardware Overview
Chapter Sections:
Hardware Features
User Reference Guide SST-PB3S-CLX-RLL
12 Hardware Overview
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
2.1 Hardware Features
The slave’s hardware features are shown below. The LCD displays the firmware version at
power up, and connection status and errors during operation. The three LEDs (COMM, SYS and
OK) display PROFIBUS and module behavior. For more detailed information on LEDs, refer to
Section 4.3, PROFIBUS LED and Display States.
Figure 1: Hardware Features
Status LEDs
Scrolling LCD Display
Configuration Port, 9-pin, male
Profibus Comm. Port, 9-pin, female
Totally-closed, module front panel
SST-PB3S-CLX-RLL User Reference Guide
Hardware Overview 13
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Table 1: Description of Features
Feature
Description
Status LEDs
Display the communication and system status
Front panel
Identifies the device, ports and protects internal electronic
components from dust, contaminants and possible damage
9-pin PROFIBUS
Connector
For connection to the PROFIBUS network
Self-locking tabs
Secure the slave in the chassis slot
Side label (nameplate)
Provides module information
Display
CLX Connection status faults, operation status
Configuration port
For upgrading module firmware
2.1.1 Status LEDs
There are three LEDs on the module, the COMM LED, SYS LED and the OK LED. For detailed
information, refer to Section 4.3, PROFIBUS LED and Display States
.
COMM LED
The COMM LED remains off while the slave is online and operating correctly. The only time
this LED remains RED is when a fatal error occurs. The COMM and SYS LED will go red at the
same time to indicate an unrecoverable fatal error.
SYS LED
The SYS LED indicates the communication status with the PROFIBUS Slave. When the SYS
LED is solid red, the PROFIBUS Slave is no longer being scanned by a DP Master, and when it
is solid green, the PROFIBUS Slave is successfully being scanned by a DP Master in Run mode.
An amber SYS LED indicates that the PROFIBUS Slave is being successfully scanned by a DP
Master that is in Clear mode.
OK LED
The OK LED indicates that initialization is complete and that the module is OK.
2.1.2 9-Pin PROFIBUS Connector
The 9-pin PROFIBUS Connector connects the slave to the PROFIBUS network.
2.1.3 Configuration Port
Use the configuration port to upgrade module’s firmware.
User Reference Guide SST-PB3S-CLX-RLL
14 Hardware Overview
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
SST-PB3S-CLX-RLL User Reference Guide
Quick Start 15
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
3
Quick Start
Chapter Sections:
Purpose
Equipment and Tools
Package Contents
Power Requirements
Procedures
User Reference Guide SST-PB3S-CLX-RLL
16 Quick Start
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
3.1 Purpose
Although this section does not include detailed information in its procedures, other chapters
are referenced where more information is available. These procedures are written with the
assumption that you have a basic understanding of process control and are fully able to
interpret the ladder logic instructions that control the applications.
3.2 Equipment and Tools
Have the following tools and equipment ready:
Computer containing Rockwell Automation RS-Logix5000 or Studio 5000 software with
Molex SST Add On Profiles
Cable to connect computer to CLX system
SST-PB3S-CLX-RLL slave module
SST-PB3S-CLX-RLL slave GSD file (ssti0EC7.gse). This can be found on the Product
CD at location CD:\Product Files\SST-PB3S-CLX-RLL\GSD
SST-PB3S-CLX-RLL ladder samples (sstpb3sclx_generic_profile_sample.acd (For
Generic Profile), sstpb3sclx_AOP_sample.acd (For Add-On-Profile). These samples can
be accessed from selecting the SST-PB3S-CLX-RLL product from product CD and
moved to PC.
PROFIBUS cable to connect the slave module to the PROFIBUS network
3.3 Package Contents
Unpack the SST-PB3S-CLX-RLL slave module. Make sure that the contents include:
PROFIBUS slave
PDF version of this manual included on the CD
CD with files for Windows XP/Server 2003 32-bit installation and Windows Vista/Server
2008/Windows 7/Windows 8 32-bit and 64-bit installations
SST-PB3S-CLX-RLL User Reference Guide
Quick Start 17
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
3.4 Power Requirements
Review your system’s power requirements to see that your chassis supports placement of the
SST-PB3S-CLX-RLL module.
Note
The module consumes 850 mA @ 5VDC, 1.75 mA @ 24VDC.
For modular systems, calculate the total load on the system power supply using the procedure
described in the CLX 5000 Modular Style Installation & Operation Manual, Allen-Bradley
Publication 1747-6.2
3.5 Procedures
The setup of the SST-PB3S-CLX-RLL slave is divided into two parts:
Setting up the slave module
Getting the slave running
3.5.1 Setting up the Slave Module
The following steps describe the SST-PB3S-CLX-RLL setup procedure:
Warning
If installing the module while the chassis is powered up, make sure the
environment is free of explosive or hazardous dusts or gases. If there is a
possibility of gases present, remove the hazardous dusts or gases, and
power down the chassis before installing the module. Serious injury or
damage to equipment may result if this warning is not followed.
1. Insert the slave module into your 1756 CLX chassis.
2. Connect the slave to the PROFIBUS network using the appropriate cabling and termination.
Refer to Section 4.2, PROFIBUS Wiring, for more detailed information.
3. Apply power to the CLX provided it is safe to do so.
4. Put the CLX PLC in Program mode. See your programming software manuals for details.
User Reference Guide SST-PB3S-CLX-RLL
18 Quick Start
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
3.5.2 Getting the Slave Module Running
The following steps describe how to set up the SST-PB3S-CLX-RLL:
1. Launch RSLogix5000 or Studio 5000 software.
2. Select I/O Configuration folder, select New Module, select Molex Incorporated in Module
Type Vendor Filters, select SST-PB3-CLX-RLL, and select Create button.
3. In General Tab, fill in the Name field, select module slot number in the chassis. In the
Module Definition area, select Change button
SST-PB3S-CLX-RLL User Reference Guide
Quick Start 19
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
4. In the Module Definition Window, select Slave in the Mode menu, then select OK.
User Reference Guide SST-PB3S-CLX-RLL
20 Quick Start
©2014 Molex Inc. Industrial Products Business Unit, Integrated Products Division
Document Edition: 1.0, Document #: 715-0109, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
5. In the Module Configuration Tab, select Slave in Mode drop-down, select Auto-Run, fill in
slave data transfer sizes, Profibus slave station number (Address), Profibus Baud rate, select
OK. See section 6.5.2 for more details on the parameters that need setting as indicated in red
below.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57

Molex SST-PB3S-CLXT-RLL User Reference Manual

Type
User Reference Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI