Heatiator ECO-ADV-WS18 User manual

Category
Stoves
Type
User manual

This manual is also suitable for

www.heatilator.com
DO NOT DISCARD THIS MANUAL
NOTICE
• Important operating
and maintenance
instructionsincluded.
• Leavethismanualwith
party responsible for
useandoperation.
• Read, understand and
followtheseinstructions
forsafeinstallationand
operation.
DO NOT
DISCARD
WARNING
If the information in these instruc-
tions is not followed exactly, a


• Donotstoreorusegasolineorotheram-
mablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
• Donotoverre-Ifheaterorchimneycon-
nectorglows,youareoverring.Overring
willvoidyourwarranty.
• Complywithallminimumclearancesto
combustiblesasspecied.Failureto
complymaycausehousere.

WARNING
Forusewithsolidwoodfuelonly.
Otherfuelsmayoverreandgenerate
poisonousgases(i.e.carbonmonoxide).
Installationandserviceofthisapplianceshould
beperformedbyqualiedpersonnel.Hearth&
HomeTechnologiesrecommendsNFIcertied
professionals,ortechnicianssupervisedbyan
NFIcertiedprofessional.
WARNING

• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLYSUPERVISEchildreninsameroomas
replace.
• Alert children and adults to hazards of high
temperatures.


• Keepclothing,furniture,draperiesandotherammable
materialsaway.
HOT SURFACES!
Glassandothersurfacesare
hotduringoperationAND
cooldown.
Owners Manual
InstallationandOperation
Model:
ECO-ADV-WS22

Heatilator•ECO-ADV-WS22•7057-128C•August13,2010 1
WS22
2
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
SAMPLE OF SERIAL NUMBER / SAFETY LABEL




CongratulationsonselectingaHeatilatorwoodburning
appliance.Thewoodburningapplianceyouhaveselected
isdesignedtoprovidetheutmostinsafety,reliabilityand
efciency.
Astheownerofanewwoodburningappliance,you’llwant
toreadandcarefullyfollowalloftheinstructionscontained
inthisowner’smanual.Payspecialattentiontoallcautions
andwarnings.
Thisowner’smanualshouldberetainedforfuturerefer-
ence.Wesuggestyoukeepitwithyourotherimportant
documentsandproductmanuals.
Yournewwoodburningappliancewillgiveyouyearsof
durableuseandtrouble-freeenjoyment.Welcometothe
Heatilatorfamilyofwoodburningproducts!


SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe
"A, ou une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
MINIMUM CLEARANCES TO COMBUSTIBLES In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD .
"For Use with Solid Wood Fuel Only"
1445 N. Highway, Colville, WA 99114
www.heatilator.com
Install and use only in accordance with
manufacturer's installation and operating
instructions. Contact local building or fire officials
about restrictions and installation inspections in
your area. Do not obstruct the space beneath
heater.
WARNING - For Mobile Homes: Do not install in
a sleeping room. An outside combustion air inlet
must be provided and unrestricted while unit is in
use. The structural integrity of the mobile home
floor, ceiling and walls must be maintained. The
stove needs to be properly grounded to the frame
of the mobile home. Components required for
mobile home installation: Outside Air Kit, Part
Number OAK-ACC.
Refer to manufacturer's instructions and local
codes for precautions required for passing
chimney through a combustible wall or ceiling and
maximum offsets.
Inspect and clean chimney frequently - Under
Certain Conditions of Use, Creosote Buildup May
Occur Rapidly.
Do not connect this unit to a chimney serving
another appliance.
Optional Components: Optional Blower, Part
BK-ACC.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route
cord under or in front of appliance.
DANGER: Risk of electrical shock. Disconnect
power supply before servicing.
Replace glass only with 5mm ceramic available
from your dealer.
Do not use grate or elevate fire. Build wood fire
directly on hearth.
Do not overfire - if heater or chimney connector
glows, you are overfiring.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to
comply with July 1990 particulate emission standards.
2010 2011 2012 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
PREVENT HOUSE FIRES
Report / Rapport: 3198460
Manufactured by:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
A B C D E F G H
SINGLE WALL PIPE 10 (254) 8.25 (210) 21 (533) 11 (279) 3.5 (89) 12.5 (318) 49 (1245) *
DOUBLE WALL PIPE 9 (229) 7 (178) 19.5 (495) 9 (229) 3 (76) 12 (305) 49 (1245) 10 (254)
SINGLE WALL PIPE 9.25 (235) 7.5 (191) 18 (457) 8 (203) 3.5 (89) 12.5 (318) 49 (1245) *
DOUBLE WALL PIPE 9.25 (235) 7.5 (191) 18 (457) 8 (203) 3 (76) 12 (305) 49 (1245) 10 (254)
VENT SPECIFICATIONS:
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or
blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney,
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a
masonry chimney and the referenced clearances
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree
Factory-built chimneys.
MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or
Security DL double wall connector pipe. Must be equipped with a spark arrestor.
Apply double wall clearances below when installing unit.
SERIAL NO.
/ NUMÉRO DE SÉRIE
WS22 WOOD STOVE
7057-125
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER
DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage
Avec Bois Solide Seulement"
Installez et utilisez en accord avec les instructions
d'installation et d'opération du fabricant. Contactez le bureau
de la construction ou le bureau des incendies au sujet des
restrictions et des inspections d'installation dans votre
voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une
chambre à coucher. Un tuyau extérieur de combustion d'air
doit être installé et ne doit pas être obstrué lorsque l'appareil
est en usage. La structure intégrale du plancher, du plafond et
des murs de la maison mobile doit être maintenue intacte.
L'appareil de chauffage doit être fixé à la charpente de la
maison mobile. Les composants requis pour l'installation des
maisons mobiles: Assemblage d'air extérieur, Numéro de
Pièce OAK-ACC.
Référez vous aux instructions du fabricant et des codes
locaux pour les précautions requises pour passer une
cheminée à travers un mur ou un plafond combustibles, et les
compensations maximums.
Inspectez et nettoyez la cheminée fréquemment. Sous
certaines conditions, il se peut que la créosote s'accumule
rapidement.
Ne pas connecter cet appareil à une cheminée servant un
autre appareil.
Composants Optionnels: Ventilateur Optionnel, Pièce
BK-ACC.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil
électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique. Déconnectez
le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5
mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement sur
l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de
PRÉVENTION DES FEUX DE MAISON
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces &
(millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de
l'entrée du conduit.
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ
CORNER INSTALLATION
INSTALLATION DU COIN
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
CONDUIT DU MUR DOUBLE
INSTALLATION: FULL VERTICAL / ENTIÈREMENT VERTICALE
INSTALLATION:
HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION:
HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in U.S.A./Fait Aux États-Unis
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée
bâtit en usine.
Fabriqué par:
007017
TESTED TO:/ TESTÉ À:
UL 1482, ULC S627-00.
A
B
C
D
INSTALLATION: 90
o
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
INSTALLATION: 90
o
DU COURBURE AU DESSUS DE HAUT DU PO
Ê
LE A TRAVERS LE MUR ARRIERE


Model Name

Manufacturer Date
SAMPLE
3
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
TABLE OF CONTENTS
Safety Alert Key:
• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.
• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedmayresultindeathorseriousinjury.
• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,mayresultinminorormoderateinjury.
• NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.
!
Congratulations...............................................................2
SampleofSafety/SerialNumberLabel...........................2
WarrantyPolicy...............................................................4-5

A. ApplianceCertications.....................................6
B. MobileHomeApproved.....................................6
C. GlassSpecications..........................................6
D. BTU&EfciencySpecications........................6
User’s Guide

A. GeneralOperatingParts...................................7
B. FireSafety.........................................................8
C. Overring...........................................................8
D. Combustible/Non-combustibleMaterial............8
E. SeasonedWood................................................8
F. ChimneyFire.....................................................8
G. BurningProcess................................................9
H. BurnRateAirControl........................................10
I. BurnRatesandOperatingEfciency................10
J. CorrectBafe&BlanketPlacement..................11
K. BuildingaFire...................................................12
L. WoodFuel.........................................................13
M. BlowerOperatingInstructions...........................14
N. ClearSpace......................................................14
O. Opacity(Smoke)...............................................15
P. FrequentlyAskedQuestions.............................15
Q. QuickStartGuide..............................................16

A. DisposalofAshes.............................................17
B. Chimney&ChimneyConnector
Inspection/Cleaning...........................................17
C. ApplianceInspection-Routine.........................17
D. GlassCleaning..................................................18
E. FirebrickInspection&Replacement.................18
F. QuickReferenceMaintenanceGuide...............19
.....................20

A. GlassReplacement...........................................21
B. SnapDiscReplacement....................................21
C. BafeRemoval..................................................22
D. DoorHandleAssembly.....................................23
E. TubeChannelAssemblyReplacement.............24
Installer’s Guide

A. Design,Installation&Location
Considerations..................................................25
B. Draft..................................................................25
C. NegativePressure.............................................25
D. LocatingYourApplianceandChimney.............26
E. ChimneyTerminationRequirements.................26
F. 2-10-3Rule.......................................................27
G. ToolsandSuppliesNeeded..............................28
H. FireSafety.........................................................28
I. InspectApplianceandComponents
andPre-BurnChecklist.....................................28
Section 7: Dimensions and Clearances
A. ApplianceDimensions.......................................29
B. ClearancestoCombustibles
(ULandULC)........30
C. HearthProtectionRequirements.......................31
D. AlternateFloorProtection.................................32

A. VentingSystems...............................................33
B. Inspections........................................................33
C. LargerChimneys...............................................33
D. ChimneySystems.............................................33
E. ChimneyHeight/RiseandRun..........................34
F. Factory-BuiltChimney.......................................34
G. MasonryChimney.............................................35
H. MasonryChimneyLiner....................................36
I. AirClearances...................................................37
J. Thimble.............................................................37-38

A. OutsideAirInstallation......................................39
D. MobileHomeInstallation...................................40
E. BlowerInstallation(Optional)............................41
F. AdjustingtheBlowerSpeedControl.................41
Section 10: Reference Materials
A. ExplodedDrawings...........................................42
B. ServiceParts&Accessories.............................43-44
C. Service&MaintenanceLog..............................45-46
D. Homeowner’sNotes..........................................47
E. ContactInformation...........................................48
4
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
Warranty Policy
Warranty Period Heatilator ECO-CHOICE


Parts  Pellet EPA Wood
1year X X
Allpartsandmaterialexceptascoveredby
Conditions,Exclusions,andLimitationslisted
3years X Firepotsandburnpots
3years 1year X X Castings
5years 3years X Manifoldtubes
5years 3years X X Fireboxandheatexchanger
90days X X
Allreplacementpartsbeyondwarrantyperiod
Seeconditions,exclusions,andlimitationsonnextpage

HEATILATOR ECO-CHOICE WARRANTY
Hearth&HomeTechnologiesInc.,onbehalfofitshearthbrands(“HHT”),extendsthefollowingwarrantyforECO-
CHOICEbyheatilatorwoodandpellethearthappliancesthatarepurchasedfromanHHTauthorizeddealer.
WARRANTY COVERAGE:
HHTwarrantestotheoriginalowneroftheHHTapplianceatthesiteofinstallation,andtoanytransferreetakingown-
ershipoftheapplianceatthesiteofinstallationwithintwoyearsfollowingthedateoforiginalpurchase,thattheHHT
appliancewillbefreefromdefectsinmaterialsandworkmanshipatthetimeofmanufacture.Afterinstallation,ifcov-
eredcomponentsmanufacturedbyHHTarefoundtobedefectiveinmaterialsorworkmanshipduringtheapplicable
warrantyperiod,HHTwill,atitsoption,repairorreplacethecoveredcomponents.HHT,atitsowndiscretion,mayfully
dischargeallofitsobligationsundersuchwarrantiesbyreplacingtheproductitselforrefundingtheveriedpurchase
priceoftheproductitself.Themaximumamountrecoverableunderthiswarrantyislimitedtothepurchaserpriceof
theproduct.Thiswarrantyissubjecttoconditions,exclusionsandlimitationsasdescribedbelow.
WARRANTY PERIOD:
Warrantycoveragebeginsonthedateofinstallation.Inthecaseofnewhomeconstruction,warrantycoveragebegins
onthedateofrstoccupancyofthedwellingorsixmonthsafterthesaleoftheproductbyanindependent,authorized
HHTdealer/distributor,whicheveroccursearlier.Thewarrantyshallcommencenolaterthan24monthsfollowingthe
dateofproductshipmentfromHHT,regardlessoftheinstallationoroccupancydate.Thewarrantyperiodforpartsand
laborforcoveredcomponentsisproducedinthefollowingtable.
7014-2122-10-10
5
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
WARRANTY COVERAGE:
• ThiswarrantyonlycoversHHTappliancesthatarepurchasedthroughanHHTauthorizeddealerordistributor.Alistof
HHTauthorizeddealersisavailableonthHHTbrandedwebsites.
• ThiswarrantyisonlyvalidwhiletheHHTapplianceremainsatthesiteoforiginalinstallation.
• Contactyourinstallingdealerforwarrantyservice.Iftheinstallingdealerisunabletoprovidenecessaryparts,contact
thenearestHHTauthorizeddealerorsupplier.Additionalservicefeesmayapplyifyouareseekingwarrantyservice
fromadealerotherthanthedealerfromwhomyouoriginallypurchasedtheproduct.
• Checkwithyourdealerinadvanceforanycoststoyouwhenarrangingawarrantycall.Travelandshippingcharges
forpartsarenotcoveredbythiswarranty.
WARRANTY EXCLUSIONS:
Thiswarrantydoesnotcoverthefollowing:
• Changesinsurfacenishesasaresultofnormaluse.Asaheatingappliance,somechangesincolorofinteriorand
exteriorsurfacenishesmayoccur.Thisisnotaawandisnotcoveredunderwarranty.
• Damagetoprinted,plated,orenameledsurfacescausedbyngerprints,accidents,misuse,scratches,melteditems,
orotherexternalsourcesandresiduesleftontheplatedsurfacesfromtheuseofabrasivecleanersorpolishes.
• Repairorreplacmentofpartsthataresubjecttonormalwearandtearduringthewarrantyperiod.Thesepartsinclude:
paint,wood,pelletandcoalgaskets;rebricks;grates;ameguides;andthediscolorationofglass.
• Minorexpansion,contraction,ormovementofcertainpartscausingnoise.Theseconditionsarenormalandcom-
plaintsrelatedtothisnoisearenotcoveredbythiswarranty.
• Damagesresultingfrom:(1)failuretoinstall,operate,ormaintaintheapplianceinaccordancewiththeinstallation
instructions,operatinginstructions,andlistingagentidenticationlabelfurnishedwiththeappliance;(2)failureto
installtheapplianceinaccordancewithlocalbuildingcodes;(3)shippingorimproperhandling;(4)improperoperation,
abuse,misuse,continuedoperationwithdamaged,corrodedorfailedcomponents,accident,orimproperly/incorrectly
performedrepairs;(5)environmentalconditions,inadequateventilation,negativepressure,ordraftingcausedbytightly
sealedconstructions,insufcientmake-upairsupply,orhandlingdevicessuchasexhaustfansorforcedairfurnaces
orothersuchcauses;(6)useoffuelsotherthanthosespeciedintheoperatinginstructions;(7)installationoruseof
componentsnotsuppliedwiththeapplianceoranyothercomponentsnotexpresslyauthorizedandapprovedbyHHT;
(8)modicationoftheappliancenotexpresslyauthorizedandapprovedbyHHTinwriting;and/or(9)interruptionsor
uctuationsofelectricalpowersupplytotheappliance.
• Non-HHTventingcomponents,hearthcomponentsorotheraccessoriesusedinconjunctionwiththeappliance.
• Anypartofapre-existingreplacesysteminwhichaninsertoradecorativegasapplianceisinstalled.
• HHT’sobligationunderthiswarrantydoesnotextendtotheappliances’capabilitytoheatthedesiredspace.Informa-
tionisprovidedtoassisttheconsumerandthedealerinselectingtheproperappliancefortheapplication.Consider-
ationmustbegiventoappliancelocationandconguration,environmentalconditions,insulationandairtightnessof
thestructure.

• Theappliancehasbeenover-redoroperatedinatmospherescontaminatedbychlorine,uorine,orotherdamaging
chemicals.Overringcanbeidentiedby,butnotlimitedto,warpedplatesortubes,rustcoloredcastiron,bubbling,
crackinganddiscolorationofsteelorenamelnishes.
• Theapplianceissubjectedtoprolongedperiodsofdampnessorcondensation.
• Thereisanydamagetotheapplianceorothercomponentsduetowaterorweatherdamagewhichistheresultof,but
notlimitedtoimproperchimneyorventinginstallation.
WARRANTY EXCLUSIONS:
• Theowner’sexclusiveremedyandHHT’ssoleobligationunderthiswarranty,underanyotherwarranty,expressor
implied,orincontract,tortorotherwise,shallbelimitedtoreplacement,repair,orrefund,asspeciedabove.Inno
eventwillHHTbeliableforanyincidientalorconsequentialdamagescausedbydefectsintheappliance.Somestates
donotallowexclusionsorlimitationofincidentalorconsequentialdamages,sotheselimitationsmaynotapplytoyou.
Thiswarrantygivesyouspecicerights;youmayalsohaveotherrights,whichvaryfromstatetostate.EXCEPTTO
THEEXTENTPROVIDEDBYLAW,HHTMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTY
SPECIFIEDHEREIN.THEDURATIONOFANYIMPLIEDWARRANTYISLIMITEDTODURATIONOFTHEEX-
PRESSEDWARRANTYSPECIFIEDABOVE.
7014-2122-10-10
6
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
1

TheECO-CHOICEbyHeatilatorwoodstovemeetstheU.S.
Environmental ProtectionAgency’s 1990 particulate emis-
sionstandards.



Thisstoveisequippedwith5mmceramicglass.Replace
glassonlywith5mmceramicglass.Pleasecontactyour
dealerforreplacementglass.


2.7gramsperhour

82.3%

11,700to27,000perhour

1,580to2,780sq.feet
dependingonclimatezone
Vent Size:
6inches

2.75cubicfeet

22inches
Fuel:
CordWood

410lbs
Model:
ECO-ADV-WS22WoodStove
 Intertek

3198460

ListedRoomHeater,SolidFuelType
Standard: UL1482andULCS627-00and
(UM)84-HUD,MobileHome
Approved.
NOTE: Hearth&HomeTechnologies,manufacturerof
thisappliance,reservestherighttoalteritsproducts,
theirspecicationsand/orpricewithoutnotice.
NOTICE: Thisinstallationmustconformwithlocal
codes.Intheabsenceoflocalcodesyoumustcomply
withtheUL1482, (UM) 84-HUD and NPFA211 inthe
U.S.A.andtheULC S627-00 and CAN/CSA-B365
Installation Codes inCanada.
• Thisapplianceisapprovedformobilehomeinstallations
whennotinstalledinasleepingroomandwhenanout-
sidecombustionairinletisprovided.
• Thestructuralintegrityofthemobilehomeoor,ceiling,
andwallsmustbemaintained.
• Theappliancemustbeproperlygroundedtotheframe
ofthemobilehomewith#8coppergroundwire,anduse
onlylisteddouble-wallconnectorpipe.
• OutsideAirKit,partOAK-ACCmustbeinstalledinamo-
bilehomeinstallation.
HeatilatorisaregisteredtrademarkofHearth&Home
Technologies.
WARNING! Risk of Fire! Hearth&HomeTechnologiesdis-
claimsanyresponsibilityfor,andthewarrantyandagency
listingwillbevoidedbythebelowactions.
DO NOT:
• Installoroperatedamagedappliance
• Modifyappliance
• InstallotherthanasinstructedbyHearth&Home
Technologies
• Operatetheappliancewithoutfullyassemblingall
components
• Overre
• InstallanycomponentnotapprovedbyHearth&
HomeTechnologies
• InstallpartsorcomponentsnotListedorapproved
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
7
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
2

WARNING! DO NOT operate appliance before reading and understanding operating instructions.
Failuretooperateapplianceaccordingtooperatinginstructionscouldcausereorinjury.
User Guide

WARNING

• DO NOTtouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLYSUPERVISEchildreninsameroomasappliance.
• Alertchildrenandadultstohazardsofhightemperatures.

• Keepclothing,furniture,draperiesandotherammablematerialsaway.
HOT SURFACES!
GlassandothersurfacesarehotduringoperationANDcooldown.
 
NOTICE:Ifyouexpectthatchildrenmaycomeintocontactwiththisappliance,werecom-
mendabarriersuchasadecorativescreen.Seeyourdealerforsuggestions.
Door Handle &
Spring Handle
Door Frame
& Glass
Hearth Pad
Firebrick
Burn Rate
Air
Control
8
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010

To provide reasonable re safety,the following should be
givenseriousconsideration:
1. Install at least one smoke detector on each oor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’splacementandinstallationinstructions,
andbesuretomaintainregularly.
2. AconvenientlylocatedClassAreextinguisher.
3. Apracticedevacuationplan,consistingofatleasttwo
escaperoutes.
4. Intheeventofachimneyre:
a. Prepareoccupantsforimmediateevacuation
b. Notifyredepartment

• 
Material made of or surfaced with wood, compressed
paper, plant bers, plastics, or any material capable
of igniting and burning, whether ame-proofed or not,
plasteredorunplastered.
• 
Materialwhichwillnotigniteandburn.Suchmaterialsare
those consisting entirely of steel, iron, brick, tile, slate,
glassorplasters,oranycombinationthereof.
• 
Sealants which will not ignite and burn: Rutland, Inc.
Fireplace Mortar #63, Rutland 76R, Nuflex 304, GE
RTV106orGERTB116(orequivalent).

Burnonlydryseasonedwood.
• Storewoodundercover,outoftherainandsnow.
• Dryandwell-seasonedwoodwillnotonlyminimizethe
chanceofcreosoteformation,butwillgiveyouthemost
efcientre.
• Evendrywoodcontainsatleast15%moisturebyweight,
andshouldbeburnedhotenoughtokeepthechimney
hotforaslongasittakestodrythewoodout-aboutone
hour.
• Itisawasteofenergytoburnunseasonedwoodofany
kind.
Deadwoodlyingontheforestoorshouldbeconsideredwet,
andrequiresfullseasoningtime.
• Standingdeadwoodcanbeconsideredtobeabout2/3
seasoned.
• Totellifwoodisdryenoughtoburn,checktheendsof
thelogs.
• Iftherearecracksradiatinginalldirectionsfromthecenter,
itisdry.
• Ifyourwoodsizzlesinthere,eventhoughthesurface
isdry,itmaynotbefullycured.

Donotover-re.
Over-ringmayignitecreosote or willdamage the
stoveandchimney.
Topreventover-ringyourstove,DONOT:
• Useammableliquids
• Overloadwithwood
• Burntrashorlargeamountsofscraplumber
• Permittoomuchairtothere
WARNING! Risk of Fire!
Symptoms of over-ring may include one or more of the
following:
• Chimneyconnectororapplianceglowing
• Roaring,rumblingnoises
• Loudcrackingorbangingsounds
• Metalwarping
• Chimneyre


• Immediatelyclosethedoorandaircontrolstoreduce
airsupplytothere.
• Ifyoususpectachimneyre,calltheredepartment
andevacuateyourhouse.
• Contact your local chimney professional and have
yourstoveandstovepipeinspectedforanydamage.
• Donotuseyourstoveuntilthechimneyprofessional
informsyouitissafetodoso.
Hearth&HomeTechnologiesWILL NOTwarrantystoves
thatexhibitevidenceofover-ring.Evidenceofover-ring
includes,butisnotlimitedto:
• Warpedairtube
• Deterioratedrefractorybrickretainers
• Deterioratedbafeandotherinteriorcomponents
 
WARNING! Risk of Fire! Achimney re canpermanently
damageyourchimneysystemandnearbystructures.
Intheeventofachimneyre,Hearth&HomeTechnolo-
giesInc.recommends
• Replacementofthechimney,and
• Inspectionoftheadjacentstructuretotheprovisionsof
NFPALevelIIIinspectioncriteria
9
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010

Inrecentyearstherehasbeenanincreasingconcernabout
airquality.Muchoftheblameforpoorairqualityhasbeen
placedontheburningofwoodforhomeheating.
Inordertoimprovethesituation,wehavedevelopedcleaner-
burningwoodappliancesthatsurpasstherequirementsfor
emissionsestablishedbyourgoverningagencies.
Thesewoodappliancesmustbeproperlyoperatedinorder
to ensure that they perform the way they are designed to
perform.

Ithelpstoknowalittleabouttheactualprocessofburningin
ordertounderstandwhatgoesoninsidetheappliance.The
rststageofburningiscalledthekindlingstage.
Inthisstage:
• Woodisheatedtoatemperaturehighenoughtoevapo-
ratethemoisturepresentinallwood.
• Woodwillreachtheboilingpointofwater(212°F)andwill
notgetanyhotteruntilthewaterisevaporated.
Thisprocesstakesheatfromthecoalsandtendstocoolthe
appliance.
Firerequiresthreethingstoburn:
• Fuel
• Air
• Heat
Ifheatisrobbedfromtheapplianceduringthedryingstage,
thenewloadofwoodhasreducedthechancesforagood
cleanburn.
Itisalwaysbesttoburndry,seasonedrewood.Whenthe
woodisn’tdry,youmustopentheaircontrolsandburnata
highburnsettingforalongertimetostartitburning.
The heat generated from the re should be warming your
home and establishing the ue draft, not evaporating the
moistureoutofwet,unseasonedwood,resultinginwasted
heat.

Inthesecondarystagewoodgivesoffammablegases
whichburnabovethefuelwithbrightames.
Duringthisstageofburning:
• Theamesmustbemaintainedandnotallowedtogo
outtoensurethecleanestpossiblere.
•Iftheamestendtogoout,it issettoolowforyour
burningconditions.
Theaircontrollocatedattheupperright hand corner is
usedtoadjustforburnrates.ThisiscalledtheBurnRate
AirControl.

Thenalstageofburningisthecharcoalstage.Thisoccurs
whentheammablegaseshavebeenmostlyburnedand
onlycharcoalremains.Thisisanaturallycleanportionof
theburn.Thecoalsburnwithhotblueames.
• It is very important to reload your appliance while
enoughlivelyhotcoalsremaininordertoprovidethe
amount of heat needed to dry and rekindle the next
loadofwood.
• It is best to open the Burn RateAir Control before
reloading. This livens up the coalbed and reduces
excessiveemissions(opacity/smoke).

• Opendoorslowlysothatashorsmokedoesnotexit
appliancethroughopening.
• Breakupanylargechunksanddistributethecoalsso
thatthenewwoodislaidonhotcoals.
Airqualityisimportanttoallofus,andifwechoosetouse
woodtoheatourhomesweshoulddosoresponsibly.
Weneedtolearntoburninthecleanestwaypossibleal-
lowingustocontinueusingourwoodappliancesformany
yearstocome.
NOTICE:Improperoperationcanturnanywoodappli-
anceintoasmolderingenvironmentalhazard.
10
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010


• The air supply enters at the upper front of the rebox,
nearthetopoftheglassdoor.
• Thispreheatedairsuppliesthenecessaryfreshoxygen
tomix with theunburned gases, helpingto create sec-
ond,thirdandfourthcombustions
• ThisairisregulatedbytheBurnRateAirControl.
• TherearefoursettingsHigh,Medium-High,Medium-Low
andLow.
• WhenthecontrolisraisedallthewayupitisontheHigh
settingand when pushed all the down it is on the Low
setting.onpage


1. Followtheinstructionsbelowforeachburnrateforthe
BurnRateAirControl.
2. Burndry,well-seasonedwood.
Burn Rates
 
• OpentheBurnRateAirControlbyraisingitalltheway
tothetopfortheHighsetting.

• Theblowertendstocooltheappliance.Leavetheblower
offuntiltheburniswellestablished,i.e.,30minutes.
• Afterloadingtheappliancewithwood and starting the
re,settheBurnRateAirControlstothedesiredsetting
byfollowingtheburnrateinstructionsbelow.
 
•
Raise the Burn Rate Air Control all the way up until it
stops(topmarker)toafullyopenposition.
•
Besureandmonitortherecloselywhileinthissettingto
avoidoverringyourstove.

 - 15,000 to 30,000 BTU/hr
• Raise the Burn Rate Air Control to the Medium High
marker.
Blowermayremainon.


• RaisetheBurnRateAirControltotheMediummarker.
Leave the blower off until the burn is well established,
i.e.,30minutes.
 
• LeavetheBurnRateAirControlatthebottommarker.
Leave the blower off until the burn is well established,
i.e.,30minutes.

Theseareapproximatesettings,andwillvarywith
type of wood or chimney draft. Due to altitude and other
environmentalcircumstances,thisoperationalinformationis
aguidelineonly.
High
Medium High
Medium
Low
11
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
CORRECT POSITION
INCORRECT POSITIONS

CeramicBlanket andBafe Boardare NOTin
contactwiththebackoftherebox.
Ceramic Blanket is NOT in contact with the
backofthereboxandNOTevenwiththeBaf-
eBoardinthefront.
CeramicBlanketisbunchedupattheback
ofthereboxandNOTevenwiththeBafe
Boardinthefront.
Ceramic Blanket
Back of Firebox
Baffle Board
Ceramic Blanket and Bafe Board MUST be in
contactwiththebackofthereboxandevenwith
eachotherinthefront.
Ceramic Blanket
Back of Firebox
Baffle Board


WARNING! Risk of Fire!
Firebox damage due to improper bafe placement is not
coveredbywarranty.Operatethewoodburningappliance
withthebafeinthecorrectpositiononly.
Notdoingsocouldresultin:
• Reducedefciency
• Overheatingthechimney
• Overheatingtherearoftherebox
• Poorperformance
Ensurecorrectbafeplacementandreplacebafecompo-
nentsifdamagedormissing.
NOTE:Thesearegenericdrawingsandmaynotrepresent
yourspecicmodel.
12
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010

Beforelightingyourrstreintheappliance:
1. Conrm the bafe and ceramic blanket are correctly
positioned.Seefordetailed diagrams.They
shouldbeevenwiththefronttubeandrestingonboth
tubes.
2. Removealllabelsfromglass.
Therearemanywaystobuildare.Thebasicprinciple
istolighteasily-ignitabletinderorpaper,whichignitesthe
fastburningkindling,whichinturnignitestheslow-burning
rewood.Hereisonemethodthatworkswell:
1. Raise
theBurnRateAirControltotheHighSetting.
2. Place several wads of crushed paper on the rebox
oor.Heatingtheuewithslightlycrumplednewspaper
beforeaddingkindlingkeepssmoketoaminimum.
3. Laysmalldrysticksofkindlingontopofthepaper.
4. Makesurethatnomatchesorothercombustiblesarein
theimmediateareaoftheappliance.Besuretheroom
isventilatedandtheueunobstructed.
5. Lightthepaperintheappliance.NEVERlightorrekindle
rewithkerosene,gasoline,orcharcoallighteruid;the
resultscanbefatal.
6. Oncethekindlingisburningquickly,addseveralfull-
lengthlogs3to4inches(76to102mm)indiameter.
Becarefulnottosmotherthere.Stackthepiecesof
wood1/2inchto1inchapart;nearenoughtokeepeach
otherhot,butfarenoughawayfromeachothertoallow
airowbetweenthem.
7. Once there is an established bed of coals, set the
BurnRateAirControltothedesiredsettingfollowing
theinstructionsfoundintheSection:BurnRatesand
OperatingEfciency.
8. Ifyouhaveinstalledtheoptionalblower,pleasenotethat
theblowertendstocooltheappliance.Leavetheblower
offuntiltheburniswellestablished,i.e.,30minutes.

NOTICE:
Buildreonbrickreboxoor.
• DoNOTusegrates,andironsorothermethodstosup-
portfuelasitwilladverselyaffectemissions.
9. Whenreadytoreload,ItisbesttosettheBurnRateAir
ControlintheHighpositionbefore reloading.
• Thislivensupthecoalbedandreducesexcessiveemis-
sions(opacity/smoke).
• Opendoorslowlysothatashorsmokedoesnotexitap-
pliancethroughopening.
• Largelogsburnslowly,holdingarelonger.
• Smalllogsburnfastandhot,givingquickheat.
10.
Aslongastherearehotcoals,repeatingsteps6through
8willmaintainacontinuousrethroughouttheseason.
WARNING! Risk of Fire! Keep combustible materials,
gasoline and other ammable vapors and liquids clear
of the replace.
Do NOT:
• Storeammablematerialsclosetothereplace,or
• Usegasoline,lanternfuel,kerosene,charcoal
lighteruidorsimilarliquidstostartor“freshenup”
areinthisreplace.
Keepallammableliquidswellawayfromthereplacewhile
itisinuse.Combustiblematerialsmayignite.
CAUTION! Odors and vapors released during initial
operation may be irritating to sensitive individuals.
Openwindowsforaircirculation.
Baffle Boards & Blanket even with
front tube and resting on tubes
Baffle
Protection
Channel
Ceramic Blanket on Top
Tube Channels
2 pc
Baffle
Board
Burn
Rate Air
Control
CAUTION
ThebafeboardsareFRAGILE.Useextremecaution
whenloadingrewoodtoprevent:
• Cracking,breakingordamagingthebafeboards
DONOToperatethestovewithoutbafeboards
13
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
 
Moisture
Seasoned Wood
• Cutlogstosize
• Splitto6inches(152mm)orlessindiameter.
• Airdrytoamoisturecontentofaround20%
- *Softwood-aboutninemonthstodry
- *Hardwood-abouteighteenmonthstodry
Soft woods Hard woods
• DouglasFir • Oak
• Pine • Maple
• Spruce • Apple
• Cedar • Birch
• Poplar
• Aspen
• Alder
Themajorityoftheproblemsapplianceownersexperience
arecausedbytryingtoburnwet,unseasonedwood.
• Wet,unseasonedwoodrequiresenergytoevaporatethe
waterinsteadofheatingyourhome,and
• Causesevaporatingmoisturewhichcoolsyourchimney,
acceleratingformationofcreosote.

Stepstoensureproperlyseasonedwood:
• Stack wood to allow air to circulate freely around and
throughwoodpile.
• Elevate wood pile off ground to allow air circulation
underneath.
• Smallerpiecesofwooddryfaster.Anypieceover6inches
(152mm)indiametershouldbesplit.
• Wood(wholeorsplit)shouldbestackedsobothendsof
eachpieceareexposedtoair.Moredryingoccursthrough
thecutendsthanthesides.
• Store wood under cover to prevent water absorption
from rain or snow.Avoid covering the sides and ends
completely.

• NOTpermittedforuseinthisappliance

Yourapplianceperformancedependsonthequalityofthe
rewoodyouuse.
• Seasonedwoodcontainsabout8,000BTUsperpound.
• Hardwoodsaremoredensethansoftwoods.
• Hardwoodscontain60%moreBTUsthansoftwoods.
• Hardwoodsrequiremoretimetoseason,burnslowerand
arehardertoignite.
• Softwoodsrequirelesstimetodry,burnfasterandare
easiertoignite.
• Starttherewithsoftwoodtobringtheapplianceupto
operatingtemperatureandtoestablishdraft.
• Addhardwoodforslow,evenheatandlongerburntime.
*NOTE:Seasoningtimemayvarydependingondrying
conditions.
WARNING! Risk of Fire!
• DoNOTburnwetorgreenwood.
• Wet, unseasoned wood can cause accumulation of
creosote.
• Storewoodindrylocation.
• Stackwoodsobothendsareexposedtoair.
WARNING! Risk of Fire! DO NOT store wood:
• Infrontoftheappliance.
• Inspacerequiredforloadingorashremoval.
WARNING

DONOTBURNGARBAGEORFLAMMABLE
FLUIDSSUCHASGASOLINE,NAPTHAOR
ENGINEOIL.
• DONOTUSECHEMICALSORFLUIDSTOSTARTA
FIRE.
 DoNOTburntreatedwoodorwoodwithsalt(driftwood).
Maygeneratecarbonmonooxideifburnmaterialother
thanwood.
Mayresultinillnessorpossibledeath.
14
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
7. 
Ifyoundtheblowercomingonandoffatundesirable
temperatures,relocatethesnapdisctoanotherlocation
inthedesignated zone on thebackof the appliance.
  There is a manual over-ride switch to
deactivatethesnapdisc,ifnecessary.
forlocationofover-rideswitch.

Blower
Snap Disc


N
• DoNOTplacecombustibleobjectswithin4ft(1.2m)of
thefrontofappliance.See.
WARNING! DoNOTplacecombustibleobjectsinfront
oftheappliance. Hightemperaturesmayigniteclothing,
furnitureordraperies.
• Mantel-avoidplacingcandlesandotherheat-sensitive
objects on mantel or hearth. Heat may damage these
objects.
NOTE:Ifyourwoodapplianceisequippedwithanoptional
blower,youshouldfollowtheseguidelines:
Burn Rate
Air Control
Handle Up = Open
Handle Down = Closed

Maintain 4 ft. (1.22m) clearance to
combustible in front of appliance
1.RaisetheBurnRateAirControl
allthewayuptotheHighsetting.
Theblowertendsto
cooltheappliance.Leavethebloweroffuntiltheburnis
wellestablished,i.e.,30minutes.
2 RaisetheBurnRateAirControlall
thewayuptotheHighsetting.Theblowermayremain
on.
3. BurnRateAir
Controlisclosedthenopenedto1inch(pullup).The
blowermayremainon.
4. Medium  BurnRateAirControlis
closed then opened to 1/4 inch to 1/2 inch (pull up).
Leavetheblowerofffortherst30minutesuntiltheburn
iswellestablished.
5.    Burn Rate Air Control is closed
(downposition).
Leavetheblowerofffortherst30min-
utesuntiltheburniswellestablished.
NOTE: Formaximumefciencyandlowestemissions,
when operating the blower in either the automatic or
manualsettingforthelowandmediumlowburnsettings
leavethebloweroffuntiltheburniswellestablished,i.e.,
30minutes,
When reloading the appliance, raise the Burn Rate Air
ControlallthewalltotheHighsettingfor5to15minutes
beforesettingtothedesiredburnrate.
6. Theblowerisequippedwitharheostat(speedcontrol).
The highest blower speed is obtained by turning the
rheostaton, then adjusting back towards“OFF” as far
as possible without turning the blower off. For a low
blowerspeed,turnthecontrolknobclockwiseasfaras
possible
15
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010

Opacity is the measure of how cleanly your appliance is
burning.
Opacityismeasuredinpercent:
• 100%opacityiswhenanobjectistotallyobscuredby
thesmokecolumnfromachimney,and
• 0%opacitymeansthatnosmokecolumncanbeseen.
As you become familiar with your appliance, you should
periodicallychecktheopacity.Thiswillallowyoutoknow
howtoburnasnearlysmoke-freeaspossible(goalof0%
opacity).

ISSUES SOLUTIONS
Odorfromappliance Whenrstoperated,thisappliancemayreleaseanodorfortherstseveralhours.Thisis
causedbythecuringofthepaintandtheburningoffofanyoilsremainingfrommanufacturing.
Metallicnoise Noiseiscausedbymetalexpandingandcontractingasitheatsupandcoolsdown,similarto
thesoundproducedbyafurnaceorheatingduct.Thisnoisedoesnotaffecttheoperationor
longevityoftheappliance.
Whirringsound Iftheoptionalblowerhasbeeninstalled,theblowerproducesawhirringsoundwhich
increasesinvolumeasthespeedisincreased.
CAUTION! Odors and vapors released during initial
operation may be irritating to sensitive individuals
.
Openwindowsforaircirculation.
16
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010


1
2
3
6
7
FIRST FIRE ITEMS NEEDED:
10PiecesofNewspaper,10-20PiecesofDryKindling
andaFewPiecesofDrySplitWood.
LOAD WOOD
ADD NEWSPAPER
ADD MORE WOOD
4
ADD KINDLING
LIGHT THE PAPER
HIGH
LOW
OPEN AIR
CONTROL
HIGH
LOW
REDUCE AIR
CONTROL
Settodesiredheat
output
5

WARNING! Risk of Fire
Closeandsecurelylatchthedoorafter
therehasstarted,andafterrefueling,to
prevent:
• Spillageofsmoke,ameandcarbon
monoxide
• Spillageofsparks,coalsandlogs
• Over-ring
DONOTleavethestoveunattendedwith
thedooropen.
Startingaremaynotrequireanopen
doorfordraft.Theaircontrolshould
supplyadequatedraft.
17
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
3

  When ash is within 1-3/4 inch (44mm) of
fireboxlip.Leave1/4to1/2inch(6-13mm)ofashinthe
bottomofthefirebox.
 Homeowner

• Placeashesinametalcontainerwithatight-ttinglid.
• The closed container should be placed on a non-
combustibleoor or ontheground, wellawayfrom all
combustiblematerials,pendingnaldisposal.
• Iftheashesaredisposedofbyburialinsoilorotherwise
locallydispersed,theyshouldberetainedintheclosed
containeruntilallcindershavethoroughlycooled
WARNING! Risk of Fire! Ashescouldcontainhotembers.


 Every2 months during heating season or
as recommended by a certied chimney sweep; more
frequentlyifchimneyexceedsorisunder14-16ft(4.3-
4.8m).(measuredfrombottomofappliance).
 CertiedChimneySweep
• Removeallashfromthereboxandextinguishallhot
embersbeforedisposal.
• Allowtheappliancetocoolcompletely.
• Disconnectuepipeorremovebafeandceramicblanket
from appliance before cleaning chimney. Otherwise
residue can pile up on top of the bafe and ceramic
blanket.(SeeBafeRemovalon).
• Closethedoortightly.
• Thecreosote orsoot should be removed with a brush
specicallydesignedforthetypeofchimneyinuse.
• Cleanoutfallenashesfromtherebox.
• Itisalsorecommendedthatbeforeeachheatingseason
theentiresystembeprofessionally inspected, cleaned
andrepairedifnecessary.
WARNING! Risk of Fire! IgnitedcreosoteisextremelyHOT.
Preventcreosotebuildup
.
WARNING! Risk of Fire!
Donotusechimneycleanersoramecolorantsinyour
appliance.Itwillcorrodeyourpipe.

• Whenwoodisburned slowly,itproducestarandother
organicvapors,whichcombinewithexpelledmoistureto
formcreosote.
• The creosote vapors condense in the relatively cool
chimneyueofaslow-burningre.
• As a result, creosote residue accumulates on the ue
lining. When ignited this creosote makes an extremely
hotre.
• Thechimneyandchimneyconnectorshallbeinspected
everytwomonthsduringtheheatingseasontodetermine
whenacreosotebuilduphasoccurred.
• Whencreosotehasaccumulateditshallberemovedto
reducetheriskofachimneyre.

Every2monthsatthesametimethechim-
neyandchimneyconnectorareinspected.
 Homeowner
Checkfor:
• Cracksinglass
• Doorhandle-smoothcamoperation
• Bafeandceramicblanketcorrectplacement
• Bafeforcracks
• Firebrickforcracks,brokenorcrumbly
• Doorgasket.(Dollarbilltest).Placeadollarbillbetween
the stove and the door and then shut the door. If you
canpullthe dollar billout, remove onespacingwasher
fromthedoorhandlebehindthelatchcamandtrythetest
again.Ifyoucanstillpullthedollarbillout,replacethe
doorgasket.
• Glassframeforloosescrews
18
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
 Asdesired
 Homeowner
• Cleanglasswithanon-abrasiveglasscleaner.Abrasive
cleanersmayscratchandcauseglasstocrack.
• Ifthedepositsontheglassarenotveryheavy,normal
glass cleaners work well. Heavier deposits may be
removedbyusingadampclothdippedinwoodashesor
byusingacommerciallyavailableovencleaner.
• Afterusinganovencleaner,itisadvisabletoremoveany
residuewith a glasscleaner or soapand water. Oven
cleaner left on during the next ring can permanently
stain the glass and damage the nish on plated metal
surfaces.
• Aportionofthecombustionairenteringthereboxisde-
ecteddownovertheinsideofthedoorglass.
• Thisairow“washes”theglass,helpingtokeepsmoke
fromadheringtoitssurface.
• Whenoperatedatalowburnrate,lessairwillbeowing
overtheglassandthesmoky,relativelycoolconditionof
alowrewillcausetheglasstobecomecoated.
• Operating the appliance with the Burn RateAirControl
intheHighsettingfor15-20minutesshouldremovethe
builtupcoating.

CAUTION! Handle glass assembly with care. Glass is
breakable.
• Avoidstriking,scratchingorslammingglass
• Avoidabrasivecleaners
• Donotcleanglasswhileitishot
Replace the rebrick if they become, cracked, broken,
crumblyand/orifthereisa1/4inch(6.35mm)gapbetween
thebricks.
Thereboxislinedwithhighqualityrebrick,whichhas
exceptional insulating properties. There is no need to
useagrate;simplybuildareonthereboxoor.Donot
operateappliancewithoutrebrick.
1. Afterthecoalshavecompletelycooled,removeallold
brickandashfromunitandvacuumrebox.
2. Removenewbricksetfromboxandlayouttodiagram
shown.
3. Laybottombricksinunit.
4. Installrearbricksonthetopofthebottombricks.Slide
topof bricks underclip on backof rebox walland
pushbottomofbrickback.
5. Installsidebricks.Slidetopofbrickunderclips on
sideofreboxandpushthebottomofthebrickuntil
itisushwiththesideoftheunit.

 Aftereachashremoval
 Homeowner

 Brick Size 
1 9x4-1/2x1-1/4 20
2 9x2-1/4x1-1/4 4
UsePart832-0550whenorderingindividualbrick.
Providebrickdimensionorcopythispage,mark
the desired brick and take it to your authorized
dealer.
19
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
Baffle
Blanket
Latch Cam
Spacing Washers
Bafe&Blanket
OptionalBlower
ChimneySystem
Firebrick&AshRemoval
Door&GlassAssemblies
DoorHandle
Frequency
MONTHLY
or
AfterEvery
CordofWood
Bafeandblanketplacementiscriticaltoheat
output,efciencyandoveralllifeoftheunit.
Makesurethebafeispushedallofthewayto
thebackofthereboxandtheblanketislaying
at.Inspectbafeforcracks.
YEARLY
or
AfterEvery
4Cordsof
Wood
Vacuumtheblowerimpellers.
EVERY2
MONTHS
or
AfterEvery
4Cordsof
Wood
Thechimneyandchimneycapmustbein-
spectedforsootandcreosoteevertwomonths
duringtheburnseasonormorefrequencyif
chimneyexceedsorisunder14-16ft(4.3m-
4.8m)measuredfrombottomofappliance.
Thiswillpreventpipeblockage,poordraft,and
chimneyres.
Alwaysburndrywoodtohelppreventcap
blockageandcreosotebuild-up.
WEEKLY
or
AfterEvery
25Loadsof
Wood
Ashesmustbecoolandthenyoucandispose
oftheashesinanon-combustiblecontainer.
Firebrickisdesignedtoprotectyourrebox.
Afterashesareremoved,inspecttherebrick
andreplacerebricksthatarecrumbling,
crackedorbroken.
WEEKLY
or
AfterEvery
25Loadsof
Wood
Keepdoorandglassgasketingoodshapeto
maintaingoodburntimesonalowburnsetting.
Totest:placeadollarbillbetweenthestoveand
doorandthenshutthedoor.Ifyoucanpullthe
dollarout,removeonewasherfromdoorhandle
behindlatchcamandtryagain.Ifyoucanstill
pullitout,replacethedoorgasket.
Checktheglassframeforloosescrewstopre-
ventairleakage.Checkglassforcracks.
WEEKLY
or
AfterEvery25
LoadsofWood
Checkthedoorlatchforproperadjustment.
Thisisveryimportantespeciallyafterthedoor
ropehasformedtothestoveface.
Checkdoorhandleforsmoothcamoperation.
Task
CAUTION! 

Starttherstinspectionaftertherst2monthsofuse,
or if performance changes, and adjust your schedule
accordingly.Maintenanceisrequiredforsafeoperation
andmustbeperformedtomaintainyourwarranty.

20
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
4

Withproperinstallation,operation,andmaintenanceyourwoodstovewillprovideyearsoftrouble-freeservice.Ifyoudo
experienceaproblem,thistroubleshootingguidewillassistyouoraqualiedservicepersoninthediagnosisofaproblem
andthecorrectiveactiontobetaken.
  Solution
Cannotgetrestarted
Excessivesmokeorspillage
Burnstooslowly
Notenoughheatoutput
Notenoughkindling/paperorno
kindling/paper
Usedrykindling,morepaper.Arrangekindling&
woodforairmovement.
Notenoughairforretoignite
Checkforrestrictedterminationcap
Checkforblockageofoutsideairkit(ifinstalled).
Checkforueblockage.
Pre-warmuebeforestartingre(refertoBuilding
aFireSection).
Checkforadequateventheight(refertoChimney
HeightSection).
Openwindowbelowtheappliancetowardsthe
wind.
Woodconditionistoowet,too
large
Usedry,seasonedwood(refertoSeasonedWood
Section).
Bedofcoalsnotestablished
beforeaddingwood
Startwithpaper&kindlingtoestablishbedof
coals(refertoBuildingaFireSection).
Flueblockagesuchasbirds’
nestsorleavesintermination
cap
Havechimneyinspectedforcreosoteandcleaned
byacertiedchimneysweep.
Downdraftornegativepressure
Competitionwithexhaust
devices
Donotuseexhaustfansduringstart-up(referto
NegativePressureSection).
Openwindowbelowtheappliancetowardsthe
wind.
Fireburnstoofast
Extremelydryorsoftwood
Mixinhardwood.
Mixinlessseasonedwoodafterreisestablished
(refertoWoodFuelSection).
Overdrafting
Checkforcorrectventheight;toomuchvertical
heightcreatesoverdrafting.
Checklocationofventtermination(referto
ChimneyTerminationRequirementSection).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Heatiator ECO-ADV-WS18 User manual

Category
Stoves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI