Oneida Air Systems DMT040404 Operating instructions

  • Hello! I've reviewed the instructions for the Oneida Air Systems Quick-Clamp Gated Tee-Joint, including the DMT040404 model and its reducers. This document details the product's components, its wall mounting instructions, and offers advice about using the blast gate for optimal performance. I'm ready to answer your questions about its features and proper usage.
  • What is included with the Quick-Clamp Gated Tee-Joint?
    How do the reducers attach to the Tee-Joint?
    What size of hose does the Tee-Joint accept?
    What hoses do the reducers accept?
    Can the gate hold its position?
Rev: 01/08/2021 Doc. #ZBI040404
Using the Reducers
e Quick-Clamp Gated Tee-Joint (A) includes two Reducers
(B) (C) for connecting various vacuum hoses to the gated
branch. e reducers attach to the branch using a friction t
thanks to the tapered shape.
• e branch itself will accept raw 4" ex hose over it, held
in place with a hose clamp (not included).
• e 4 to 2-1/2" Reducer (B) will accept any standard
2-1/2" vacuum hose and assorted cus.
• e 4 to 1-1/2" Reducer (C) will accept any standard
1-1/2" vacuum hose and assorted cus.
Note: In some rare cases, your hose cus may match the
diameter of the Reducers and will require a hose coupler to join
the two ttings together.
Using the Blast Gate
To preserve airow performance, the blast gate should be
closed o when the tool connected to it is not in use.
When opening and closing the blast gate, the plate will hold
its position thanks to the internal magnetic brake.
Note: Your dust collector must always have at least one branch
open during operation to avoid "dead-heading" the system.
Wall-Mounting Instructions
Aer all of your ductwork has been connected and installed,
the Tee-Joint can be directly fastened to the wall for further
stability and security.
Using a long bit driver extension for your power drill, insert
through the open gated branch and pre-drill a hole through
the protrusion on the side of the Tee-Joint and into the wall
[FIG. 1].
Secure the Tee-Joint in place using a suitable screw, rubber
washer, and at washer to ensure a proper airtight seal within
the duct.
Note: e remainder of your ducting should use its own wall-
mounts and not rely on the Tee-Joint for support. You must
provide your own wall mounting hardware.
Quick-Clamp Gated Tee-Joint
Contact our Customer Service Department for further assistance
1-866-387-8822 • support@oneida-air.com • oneida-air.com/contact-us
1001WestFayetteStreet,Syracuse,NY13204U.S.A.•Copyright©2021OneidaAirSystems,Inc.
Recommended Tools:
• Power Drill
• Wall Mounting Hardware
• 8" Drill Bit Extension
ID Part Number Part Description Qty
A DMT040404 Quick-Clamp Gated Tee-Joint 1
B ———— 4 to 2-1/2 Reducer 1
C ———— 4 to 1-1/2 Reducer 1
BA
C
FIG. 1
Wall
/