Alecto SA-18 User manual

Type
User manual
DECLARATION OF PERFORMANCE
No. 001CPR2016-11-26
1. Unique identification code of the product-type:
Alecto SA-19/5
Alecto SA-29/5
2. Type, batch or serial number or any other element allowing identification of the construction
product as required under Article 11(4):
Optical Smoke Alarm Device KD-127B
3. Intended use or uses of the construction product, in accordance with the applicable
harmonized technical specification, as foreseen by the manufacturer:
Fire detection and installed in buildings
4. Name, registered trade name or registered trade mark and contact address of the
manufacturer as required pursuant Article 11(5):
Hesdo B.V., Azielaan 12, 5232 BA, s’-Hertogenbosch, The Netherlands.
5. Where applicable, name and contact address of the authorized representative whose
mandate covers the tasks specified in Article 12(2):
Not applicable
6. System or systems of assessment and verification of constancy of performance of the
construction product as set out in Annex V:
System 1
7. In case of the declaration of performance concerning a construction product covered by a
harmonised standard:
EN14604 : 2005 / AC:2008
ANPI 1134
Performed type testing and the initial inspection of the manufacturing plant and of the factory
production control with continuous surveillance assessment and approval of the factory
production control under system 1 and issued the EC certificates of conformity:
1134-CPR-209
8. Declared performance
Essential characteristics
Performance
Harmonized technical
specification
EN 14604:2005/AC:2008
Nominal activation conditions/
Sensitivity,Response delay (response
time) and Performance under fire
condition
PASS
4.12, 5.2, 5.3, 5.4, 5.5, 5.6,
5.15, 5.17, 5.18 and 5.20
Operational reliability
PASS
4.1, 4.2, 4.5, 4.6, 4.7, 4.9, 4.10,
4.11, 4.13, 4.14, 4.15, 4.16,
4.19, 5.11, 5.16 and 5.24
Tolerance to supply voltage
PASS
5.21
Durability of operational reliability and
response delay, Temperature resistance
PASS
5.7 and 5.8
Durability of operational reliability,vibration
resistance
PASS
5.12 and 5.13
Durability of operational reliability,humidity
resistance
PASS
5.9
Durability of operational
reliability,corrosion resistance
PASS
5.10
Durability of operational
reliability,electrical stability
PASS
5.14
Notes:The products covered by this standard are assumed to operate, in an event of fire, before
the fire becomes so large as to affect their functioning. There is therefore no requirement to
function when exposed to direct attack from fire.
9. The performance of the product identified in points 1 and 2 is in conformity with the declared
performance in point 8.
This declaration of performance is issued under the sole responsibility of the manufacturer
identified in point 4.
Signed for and on behalf of the manufacturer by:
J.H.A.M. Roording CTO
S’-Hertogenbosch July 3, 2018
  • Page 1 1
  • Page 2 2

Alecto SA-18 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI