Channel Vision 6210, P-6014 User manual

  • Hello! I am an AI chatbot trained to assist you with the Channel Vision 6210 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
P-6014
6210
CAT5 Camera Sequencer
Color CAT5 Camera
PRO
PRO
8
L
uoop
O t 1L
uoop
O t 1
oop
O
t 2L
u
oop
O
t 2L
u
Loop Out
3
Loop Out
3
Loo
ut 4p O
Loo
ut 4p O
n
Mo
itor
1
n
Mo
itor
1
M nitor
o
2M nitor
o
2
IR o
In (
M n 1)
IR o
In (
M n 1)
ut 2
IR O
(Mo
n
)
ut 2
IR O
(Mo
n
)
Po
er
wPo
er
w
p
In
utsp
In
uts
ame 1C ra
ame 1C ra
Cam
ra 2
e
Cam
ra 2
e
C
a 3ame
r
C
a 3ame
r
mer
a
Ca 4
mer
a
Ca 4
VideoVideo
io
Audio
Aud
PR
O
C
H
A N N E L
MT
V I S
I
O
N
C
H
A N N E L
V I S
I
O
N
MT
Mo
d
e
l
P-6 140
ide
Pr
sent
V o e
ide
Pr
sent
V o e
Ca
era 1
m
Ca
era 1
m
Ca
era 2
m
Ca
era 2
m
a
C mera
3
a
C mera
3
C era 4
am
C era 4
am
RS-232RS-232
T m j st
i e
Ad u
T m j st
i e
Ad u
CA
5 C M A
SE
QU
CER
T
A
ER
EN
oldHoldH
L o
Out 1
o p
L o
Out 1
o p
L
t 2
oop
OuL
t 2
oop
Ou
L
o Out 3
o p
L
o Out 3
o p
t 4
Loo
p Ou
t 4
Loo
p Ou
Monito
r 1Monito
r 1
n r 2Mo ito
n r 2Mo ito
(M
n )IR In
o
1
(M
n )IR In
o
1
IR
Out (Mon
2)
IR
Out (Mon
2)
Po
we
r
Po
we
r
p ts
In up ts
In u
Ca ra
1
meCa ra
1
me
Came
ra
2 Came
ra
2
Ca ra 3
me
Ca ra 3
me
4Ca
mera 4Ca
mera
d o
V
i
ed o
V
i
e
Au
dio
Au
dio
PRO
C
H
A
N N
E L
TM
I
V I
S
O
N
C
H
A
N N
E L
I
V I
S
O
N
TM
M
o
d
e
l
6 14P- 0
i
e
V deo Pre
s nt
i
e
V deo Pre
s nt
Camera 1Camera 1
me a
Ca
r 2me a
Ca
r 2
Camera
3Camera
3
C
meraa 4
C
meraa 4
RS-23
2
RS-23
2
T
ju
t
ime Ad
sT
ju
t
ime Ad
s
A
5 A
QU C
C
T
C MER
A S
E EN ER
Hold
Hold
2
3
Accessories (Sold Separately)
Complementary Product (Sold Separately)
IR-3001 & IR-3002 ... Single and dual head IR flashers.
Use one head per source to control from the remote
room. (IR-3002 shown).
W4000 ... Web Camera
Server allows any 4
camera video signals to
be viewed through the
local network or internet
on any computer.
A0505 ... Remote control. Contains IR codes for
controlling the P-6014 as well as many other Channel
Vision audio/video products.
3112 ... CAT5 audio/video interface. Allows audio,
video, power, and IR signals to be connected to the
CAT5 cable. It can be used to transform a traditional
camera into a CAT5 camera, or used to extract audio
and video from the Monitor 2 output of the P-6014.
When used on the Monitor 2 output, the IR input jack
can be used to input IR signals that allow Monitor 2 to
select different camera views than Monitor 1.
The 6210 Color CAT5 camera with audio mounts in a single
gang J-box or low-voltage ring and is designed to be
connected directly to the P-6014 camera inputs. The P-6014
provides loop out connections that allow the camera signals
to be connected to another device such as a DVR or
modulator.
P-6014 Features:
!
Creates an easy interface for CAT5 cameras
!
Switches both audio and video
!
Monitor output sequences through the camera views automatically
!
IR and Serial Control options
!
Mounts in a structured wire enclosure
!
Cost effective and easy to install
6210 Features:
!
BNC & CAT5 output
!
Built-in microphone
!
Screwless trim plate
!
Mounts in a 1-gang box
!
Easy to install
The P-6014 is a 4 input 2 output camera sequencer and switcher for Channel
Vision’s 6210 color CAT5 cameras (sold separately). Easily view any of the
cameras simply by letting them sequence through the screen automatically or
by pressing a button on the optional remote control. The RS-232 interface as
well as audio/video loop out connections make it easy to integrate the P-6014
into any security system - from basic to the most complex.
CH ANN EL V ISI ON
S
O
U
R
C
E
ZONE
POWER
MUTE
4
3
2
1
CAMERA
CATV
MOD
VOL
1
2
3
4
MODEL
A0505
POWER
RS-232...
Connect serial
controller here
BNC Video Output...
Connect coax here to use
as a conventional camera
RJ-45 Output...
Connect CAT5 here to use
with P-6014
Camera Power & Audio Out...
Audio out from microphone
Ground (shared)
+12VDC
Monitor 1...
Connect audio/video
monitor here
IR In (Mon 1)...
Connect an IR receiver
or an IR system
IR Out (Mon 2)...
Outputs IR signals
received via the 3112
connected to Monitor 2
Power...
Connect power
supply here
Inputs...
Connect CAT5 cameras here
Monitor 2...
Connect 3112 here to provide a secondary
monitor output, independent from Monitor 1
Loop Out...
Provides
Audio/Video output
from each camera
Time Adjust... Changes the time
period the cameras are viewed
before switching. The maximum
setting will stop cycle mode and
show the current camera.
Video Present...
LED indicators light when video
signal is detected.
2129 ... RCA to BNC adaptor. Use to adapt video
signals on BNC cables (such as cameras) to the RCA
video input commonly found on TVs and monitors.
11
22
33
44
75 ohm75 ohm
com 1com 1
GPIOGPIO
12VDC12VDC
EthernetEthernet
Camera 1Camera 1 Camera 2Camera 2 Camera 3Camera 3 Camera 4Camera 4
com 2com 2
11
tLoo
p Ou
1tLoo
p Ou
1
L o Ou
t 2
o
pL o Ou
t 2
o
p
Loop O
ut 3
Loop O
ut 3
L o
t 4
o
p Ou
L o
t 4
o
p Ou
n r 1
Mo iton r 1
Mo ito
Monitor 2Monitor 2
IR In (
Mon 1)IR In (
Mon 1)
t
IR
Ou (M
on
2)
t
IR
Ou (M
on
2)
r
Po
we
r
Po
we
InputsInputs
Cam
ra
1
e
Cam
ra
1
e
a
r 2C me
aa
r 2C me
a
Cam ra 3
e
Cam ra 3
e
Ca
r 4
me a
Ca
r 4
me a
Vid
o
eVid
o
e
u
io
A
du
io
A
d
PRO
C
H A N N
E
L
TM
V I S
I O
N
C
H A N N
E
L
V I S
I O
N
TM
M
o
d
e
l
6
1
4P- 0
i
e
V deo Pre
s nti
e
V deo Pre
s nt
Camera 1Camera 1
me a
Ca
r 2me a
Ca
r 2
Camera 3Camera 3
C
meraa 4
C
meraa 4
RS-232
RS-232
T
ju
t
ime Ad
sT
ju
t
ime Ad
s
A
5 A
QU C
C
T C MER
A SE EN ER
Hold
Hold
2
3
Accessories (Sold Separately)
Complementary Product (Sold Separately)
IR-3001 & IR-3002 ... Single and dual head IR flashers.
Use one head per source to control from the remote
room. (IR-3002 shown).
W4000 ... Web Camera
Server allows any 4
camera video signals to
be viewed through the
local network or internet
on any computer.
A0505 ... Remote control. Contains IR codes for
controlling the P-6014 as well as many other Channel
Vision audio/video products.
3112 ... CAT5 audio/video interface. Allows audio,
video, power, and IR signals to be connected to the
CAT5 cable. It can be used to transform a traditional
camera into a CAT5 camera, or used to extract audio
and video from the Monitor 2 output of the P-6014.
When used on the Monitor 2 output, the IR input jack
can be used to input IR signals that allow Monitor 2 to
select different camera views than Monitor 1.
The 6210 Color CAT5 camera with audio mounts in a single
gang J-box or low-voltage ring and is designed to be
connected directly to the P-6014 camera inputs. The P-6014
provides loop out connections that allow the camera signals
to be connected to another device such as a DVR or
modulator.
P-6014 Features:
!
Creates an easy interface for CAT5 cameras
!
Switches both audio and video
!
Monitor output sequences through the camera views automatically
!
IR and Serial Control options
!
Mounts in a structured wire enclosure
!
Cost effective and easy to install
6210 Features:
!
BNC & CAT5 output
!
Built-in microphone
!
Screwless trim plate
!
Mounts in a 1-gang box
!
Easy to install
The P-6014 is a 4 input 2 output camera sequencer and switcher for Channel
Vision’s 6210 color CAT5 cameras (sold separately). Easily view any of the
cameras simply by letting them sequence through the screen automatically or
by pressing a button on the optional remote control. The RS-232 interface as
well as audio/video loop out connections make it easy to integrate the P-6014
into any security system - from basic to the most complex.
CH ANN EL V ISI ON
S
O
U
R
C
E
ZONE
POWER
MUTE
4
3
2
1
CAMERA
CATV
MOD
VOL
1
2
3
4
MODEL
A0505
POWER
RS-232...
Connect serial
controller here
BNC Video Output...
Connect coax here to use
as a conventional camera
RJ-45 Output...
Connect CAT5 here to use
with P-6014
Camera Power & Audio Out...
Audio out from microphone
Ground (shared)
+12VDC
Monitor 1...
Connect audio/video
monitor here
IR In (Mon 1)...
Connect an IR receiver
or an IR system
IR Out (Mon 2)...
Outputs IR signals
received via the 3112
connected to Monitor 2
Power...
Connect power
supply here
Inputs...
Connect CAT5 cameras here
Monitor 2...
Connect 3112 here to provide a secondary
monitor output, independent from Monitor 1
Loop Out...
Provides
Audio/Video output
from each camera
Time Adjust... Changes the time
period the cameras are viewed
before switching. The maximum
setting will stop cycle mode and
show the current camera.
Video Present...
LED indicators light when video
signal is detected.
2129 ... RCA to BNC adaptor. Use to adapt video
signals on BNC cables (such as cameras) to the RCA
video input commonly found on TVs and monitors.
11
22
33
44
75 ohm75 ohm
com 1com 1
GPIOGPIO
12VDC12VDC
EthernetEthernet
Camera 1Camera 1 Camera 2Camera 2 Camera 3Camera 3 Camera 4Camera 4
com 2com 2
11
L
o O
t 1
o
p uL
o O
t 1
o
p u
O
Loop ut
2O
Loop ut
2
L o O
t 3
o p uL o O
t 3
o p u
L
op
O t 4
o
uL
op
O t 4
o
u
n to
Mo i r 1
n to
Mo i r 1
Mo
nitor 2Mo
nitor 2
IR
In
(
on 1)
MIR
In
(
on 1)
M
O t (
n )IR
u Mo 2O t (
n )IR
u Mo 2
P e
ow
r
P e
ow
r
In uts
pIn uts
p
Camera
1Camera
1
C me
ra
2aC me
ra
2a
C
me
a
a
r 3
C
me
a
a
r 3
C
me a
a
r
4
C
me a
a
r
4
VideoVideo
oAudi
oAudi
PR
O
C
H
A
N N
E
L
M
T
V I O
NI S
C
H
A
N N
E
L
V I O
NI S
M
T
M
d l
o
e
P
-6
0
14
deV
i
o P
resent
deV
i
o P
resent
Came
ra 1
Came
ra 1
Camera 2
Camera 2
Ca
mera 3Ca
mera 3
Came
ra 4
Came
ra 4
RS
-232
RS
-232
me dj
T
i
A ustme dj
T
i
A ust
U
CA
T5
CA
M
ER
A
SE
Q EN
C
ER
H d
ol
H d
ol
oop Ou
1
L
t
oop Ou
1
L
t
Loo
p O
ut 2Loo
p O
ut 2
Loop Out 3Loop Out 3
Loo
p O
ut 4
Loo
p O
ut 4
Monito
r 1
Monito
r 1
Mon
t
2
i or
Mon
t
2
i or
R I Mo
n 1)
I n (R I Mo
n 1)
I n (
IR
Ou
t (M
on 2)
IR
Ou
t (M
on 2)
Pow
er
Pow
er
Inp
utsInp
uts
a 1
Ca
me
r
a 1
Ca
me
r
Camera
2
Camera
2
a
Camer
3
a
Camer
3
Cam ra
4
e
Cam ra
4
e
V
i eo
dV
i eo
d
Audio
Audio
O
P
R
H
A N
N
L
C E
TM
I S
O
V
I
N
H
A N
N
L
C E
I S
O
V
I
N
TM
o e
l M d
-
0
1
4
P
6
i resentV deo P
i resentV deo P
C era
am
1C era
am
1
Camera
2Camera
2
Camera 3Camera 3
a
C mera 4
a
C mera 4
S
R -23
2
S
R -23
2
T
m
sti e Adj
uT
m
sti e Adj
u
A C EC
T5
AM
ERA S
EQUENC R
HoldHold
6125
3112
4
5
P-6014
TV (Monitor)
6210
6210
6210
6210
P-6014 Camera Sequencer Basic Application...
The primary function of the P-6014 is to sequence through its 4 camera inputs.
The Time Adjust control determines the length of time each camera view is
shown before switching to the next camera view. Unless the RS-232 or IR
remote control features are used, the P-6014 will remain in the Auto Cycle
mode. If only three of the four inputs have an active video signal, only the three
active camera inputs will be shown when in the Auto Cycle mode.
The 6210 camera was specifically designed to work together with the P-6014.
A single CAT5 cable provides power to the camera and delivers video and
audio signals back to the sequencer. These audio/video signals are output
through the monitor connections on the P-6014.
The P-6014 can be used with Channel Vision’s 6210 CAT5 camera or any
conventional camera when used with the 3112 accessory. The 3112 has
multiple applications, but when used in this application the IR connection will
not be used and the Audio connection would only be used if your conventional
camera has a built-in microphone.
P-6014
IR-2400
C
HANN
ISI ON
EL V
S
O
U
R
C
E
O
Z N
E
P W
O
ER
M
EUT
4
3
2
1
C
A
M
E
R
A
T
CA
V
M
OD
V
O
L
1
2
3
4
M LOD
E
A
50
0 5
P R
OWE
4
3
2
1
CAMERA
Using The A0505 Remote Control... P-6014 Camera Sequencer
The A0505 is designed to allow you to control the switching functions on your
P-6014. The A0505 allows you to choose any of the 4 cameras or select the
Auto Cycle mode.
Note: Only one
camera connection is
shown in this diagram,
but the P-6014 can
support up to 4 CAT5
cameras.
Remote Control Key:
Camera Next... Changes the Monitor output to the next
active camera in the sequence. If you are viewing camera 1,
pressing it once will show camera 2 and so on. Note: Any
unused camera inputs will be skipped.
Camera Cycle... Causes the Monitor output to sequence
through the cameras. The time adjustment on the P-6014 determines
how long each camera view is displayed before switching to the next one.
Note: Any unused camera inputs will be skipped.
1, 2, 3, 4 Camera Views... Changes the Monitor output directly to the
corresponding camera input.
Max CAT5 length between
3112 and 6210 is 250ft.
o
O
t 1
Lo
p u
o
O
t 1
Lo
p u
L op
Out 2
o
L op
Out 2
o
o O
t
Lo p u
3o O
t
Lo p u
3
o
O t 4
Lo
p u
o
O t 4
Lo
p u
Monitor 1Monitor 1
M
nitoro 2
M
nitoro 2
IR
In
(
on
)
M
1IR
In
(
on
)
M
1
IR Ou
t (Mon
2)
IR Ou
t (Mon
2)
Powe
r
Powe
r
I unp tsI unp ts
C mera
1aC mera
1a
me a
Ca r
2me a
Ca r
2
me
a
Ca
r 3me
a
Ca
r 3
Ca
mera
4
Ca
mera
4
d
Vi eod
Vi eo
Au
iodAu
iod
PR
O
C
H
A
N N
E L
TM
V I S I O
N
C
H
A
N N
E L
V I S I O
N
TM
Mo
de
l
P 6
-
0
1
4
deV
i
o P
resent
deV
i
o P
resent
amera
C
1
amera
C
1
Camera 2
Camera 2
Ca
mera 3Ca
mera 3
Came
ra 4
Came
ra 4
RS
-232
RS
-232
me dj
T
i A ustme dj
T
i A ust
U
CA
T5
CA
M
ER
A
SE
Q EN
C
ER
H d
ol
H d
ol
op Ou
1
Lo
top Ou
1
Lo
t
L
p O
ut oo 2
L
p O
ut oo 2
Lo p Out o 3Lo p Out o 3
oop Ou 4
L
t
oop Ou 4
L
t
M ni
or 1
o tM ni
or 1
o t
Monito
r 2
Monito
r 2
R M
n 1)
I In (
oR M
n 1)
I In (
o
IR ( o ) Ou
t M
n 2IR ( o ) Ou
t M
n 2
Pow
er
Pow
er
Inp
utsInp
uts
a
Ca
mer
1
a
Ca
mer
1
m a 2
Ca
er m a 2
Ca
er
Camera 3Camera 3
a
4
Camer
a
4
Camer
V
i odeV
i ode
A i
ud
o
A i
ud
o
RO
P
C H AN
N E
L
TM
V
I
S
I
ON
C H AN
N E
L
V
I
S
I
ON
TM
Mo
de
l
-
0
1
4
P
6
i resentV deo Pi resentV deo P
era
Cam
1
era
Cam
1
Camera
2Camera
2
Camera
3
Camera
3
a
C mera 4
a
C mera 4
S
R -23
2
S
R -23
2
T
m
st
i e Adj
uT
m
st
i e Adj
u
CA
T5 C
AM
ERA S
EQUENC
ER
old
H
old
H
6125
3112
4
5
P-6014
TV (Monitor)
6210
6210
6210
6210
P-6014 Camera Sequencer Basic Application...
The primary function of the P-6014 is to sequence through its 4 camera inputs.
The Time Adjust control determines the length of time each camera view is
shown before switching to the next camera view. Unless the RS-232 or IR
remote control features are used, the P-6014 will remain in the Auto Cycle
mode. If only three of the four inputs have an active video signal, only the three
active camera inputs will be shown when in the Auto Cycle mode.
The 6210 camera was specifically designed to work together with the P-6014.
A single CAT5 cable provides power to the camera and delivers video and
audio signals back to the sequencer. These audio/video signals are output
through the monitor connections on the P-6014.
The P-6014 can be used with Channel Vision’s 6210 CAT5 camera or any
conventional camera when used with the 3112 accessory. The 3112 has
multiple applications, but when used in this application the IR connection will
not be used and the Audio connection would only be used if your conventional
camera has a built-in microphone.
P-6014
IR-2400
C A
I
H
NNEL V IS ON
S
O
U
R
C
E
O
Z N
E
POWER
M
UTE
4
3
2
1
C
A
M
ER
A
CA
TV
M
OD
V
O
L
1
2
3
4
M
OD
E
L
0A05
5
POWER
4
3
2
1
CAMERA
Using The A0505 Remote Control... P-6014 Camera Sequencer
The A0505 is designed to allow you to control the switching functions on your
P-6014. The A0505 allows you to choose any of the 4 cameras or select the
Auto Cycle mode.
Note: Only one
camera connection is
shown in this diagram,
but the P-6014 can
support up to 4 CAT5
cameras.
Remote Control Key:
Camera Next... Changes the Monitor output to the next
active camera in the sequence. If you are viewing camera 1,
pressing it once will show camera 2 and so on. Note: Any
unused camera inputs will be skipped.
Camera Cycle... Causes the Monitor output to sequence
through the cameras. The time adjustment on the P-6014 determines
how long each camera view is displayed before switching to the next one.
Note: Any unused camera inputs will be skipped.
1, 2, 3, 4 Camera Views... Changes the Monitor output directly to the
corresponding camera input.
Max CAT5 length between
3112 and 6210 is 250ft.
p
Ou
Loo t
1p
Ou
Loo t
1
L
ut
oop O
2
L
ut
oop O
2
Lo
t
op
Ou 3
Lo
t
op
Ou 3
op
Ou 4
Lo top
Ou 4
Lo t
i o 1
Mo
n t ri o 1
Mo
n t r
Mo
nitor 2Mo
nitor 2
R
)
I In (Mo
n
1
R
)
I In (Mo
n
1
I
(
o )
R O
ut M n 2
I
(
o )
R O
ut M n 2
wer
Po
wer
Po
Inputs
Inputs
Came
ra 1
Came
ra 1
a 2Ca
me
r
a 2Ca
me
r
C
m
ra 3a e
C
m
ra 3a e
a 4Ca
mer
a 4Ca
mer
V
ideoV
ideo
A
i
ud
oA
i
ud
o
PR
O
H N
C
A
N
E
L
MT
I
V SI ON
H N
C
A
N
E
L
I
V SI ON
MT
M
od
el
0
P-6
14
Vi
deo rese
nt
P
Vi
deo rese
nt
P
Camera
1Camera
1
Cam
era 2
Cam
era 2
C
era
am
3
C
era
am
3
a
C
mer
a 4a
C
mer
a 4
S-2
32
R
S-2
32
R
T m
A ust
i
e
djT m
A ust
i
e
dj
A C
M
CE
RC T5
A ERA
SEQ
UE
N
ld
Ho
ld
Ho
6
P-6014
TV (Monitor 1)
Home Theater TV (Monitor 2)
6210
3112
IR-3200
Not used
Connect an IR emitter
to the IR Output to
allow IR pass-through.
Video In
2129
BNC to RCA adaptor
Audio In
Max CAT5 length between
3112 and 6210 is 250ft.
Controlling The P-6014 Through The Monitor 2 Connection...
Controlling the P-6014 through the IR Input connection will only affect the
Monitor 1 output. To control the Monitor 2 output, IR signals must come
through the Monitor 2 output RJ-45 connection via the 3112 as shown below.
In this diagram, when IR signals are received through the IR-2400
they are sent back to the P-6014 through the 3112. These IR
signals will only affect the Monitor 2 output. The Monitor 1 output
can be independently controlled by connecting an IR receiver to
the “IR Input” jack on the P-6014.
In this configuration, the P-6014 allows IR pass through so that IR signals
intended for other devices (such as a whole-house music system) will be
routed out the “IR Output” jack on the P-6014.
Note: Only one
camera is shown,
but the P-6014 can
support up to 4
CAT5 cameras.
IR-2400
CHAN EL
ON V
ISI
N
S
O
U
R
C
E
ZO
N
E
W R
PO E
M
UT
E
4
3
2
1
C
AMERA
CA
T
V
MOD
O
V L
1
2
3
4
M
OD
EL
5 5
A0 0
O
P
WER
op Ou
1
Lo
top Ou
1
Lo
t
L op Ou
t 2
oL op Ou
t 2
o
Loop Out 3Loop Out 3
oop Ou 4
L
toop Ou 4
L
t
Monito
r 1
Monito
r 1
M n
2
o itor
M n
2
o itor
R M
n 1)
I In
( oR M
n 1)
I In
( o
IR t (Mo
n 2)
Ou
IR t (Mo
n 2)
Ou
Pow
er
Pow
er
Inp
t
u s
Inp
t
u s
a 1Ca
mer
a 1Ca
mer
Cam ra
2
e
Cam ra
2
e
Camera 3Camera 3
C m ra
4
a
e
C m ra
4
a
e
V
i eo
dV
i eo
d
A diu
o
A diu
o
O
P
R
H
A N
N
L
C E
TM
I O
V S
I
N
H
A N
N
L
C E
I O
V S
I
N
TM
o e
l M d
-
0
1
4
P
6
entVideo Pre
sentVideo Pre
s
Cam
era 1
Cam
era 1
Camera
2Camera
2
Cam
era
3
Cam
era
3
Ca era
4
mCa era
4
m
S
R -23
2S
R -23
2
Time Adj
ustTime Adj
ust
CA 5
CAMERA S
E UENCER
T Q
old
H
old
H
7
P-6014
RJ-45 Jack
(TIA 568A)
Camera Inputs
TV (Monitor 1)
Home Theater TV (Monitor 2)
6210
3112
Not used
Video In
2129
BNC to RCA adaptor
Audio In
RJ-45 Pin Out Diagram...
For troubleshooting purposes, it may be helpful to know the wire pin out for the
RJ-45 jacks on the P-6014. They are shown below:
Note: Only one
camera is shown,
but the P-6014 can
support up to 4
CAT5 cameras.
Connect serial data controller
to the Serial port
(Hex codes on pages 8-11)
Controlling The P-6014 Through The RS-232 Port...
The RS-232 port is the most flexible way to control the P-6014 because it
provides access to every feature on the unit. This is the preferred way for most
high-end control system to interface with devices such as the P-6014.
Pin
Signal
Gnd
Video
Gnd
N.C.
Gnd
Audio
Gnd
+12VDC
8
7
6
5
4
3
2
1
Monitor 2 Output
Pin
Signal
Gnd
Video
Gnd
IR
Gnd
Audio
Gnd
+12VDC
8
7
6
5
4
3
2
1
8 7 6 5 4 3 2 11
Loo
p
Ou
t 1
Loo
p
Ou
t 1
Loo
p O
ut 2
Loo
p O
ut 2
o
L op
Out 3
o
L op
Out 3
Ou
Loop t
4Ou
Loop t
4
o
Mo
nit r 1
o
Mo
nit r 1
Mo
n tor 2
i
Mo
n tor 2
i
IR
In (Mon 1
)
IR
In (Mon 1
)
(
o
IR Out M n 2
)
(
o
IR Out M n 2
)
r
Pow
e
r
Pow
e
Inputs
Inputs
Cam
ra 1
e
Cam
ra 1
e
Ca
me
ra 2
Ca
me
ra 2
a 3Ca
me
r
a 3Ca
me
r
Ca
mera 4Ca
mera 4
V
ide
oV
ide
o
Aud
io
Aud
io
O
PR
H A
N N L
C
E
TM
I
O
V SI N
H A
N N L
C
E
I
O
V SI N
TM
M
od
el
014
P-6
Vi
deo
rese
nt
P
Vi
deo
rese
nt
P
Camera
1Camera
1
Cam
era 2
Cam
era 2
C
era
am
3
C
era
am
3
a
C
mer
a 4a
C
mer
a 4
S-232
R
S-232
R
T m
A ust
i
e
djT m
A ust
i
e
dj
A C
M CERC T5 A ER
A
SEQ
UE
N
ld
Ho
ld
Ho
6
P-6014
TV (Monitor 1)
Home Theater TV (Monitor 2)
6210
3112
IR-3200
Not used
Connect an IR emitter
to the IR Output to
allow IR pass-through.
Video In
2129
BNC to RCA adaptor
Audio In
Max CAT5 length between
3112 and 6210 is 250ft.
Controlling The P-6014 Through The Monitor 2 Connection...
Controlling the P-6014 through the IR Input connection will only affect the
Monitor 1 output. To control the Monitor 2 output, IR signals must come
through the Monitor 2 output RJ-45 connection via the 3112 as shown below.
In this diagram, when IR signals are received through the IR-2400
they are sent back to the P-6014 through the 3112. These IR
signals will only affect the Monitor 2 output. The Monitor 1 output
can be independently controlled by connecting an IR receiver to
the “IR Input” jack on the P-6014.
In this configuration, the P-6014 allows IR pass through so that IR signals
intended for other devices (such as a whole-house music system) will be
routed out the “IR Output” jack on the P-6014.
Note: Only one
camera is shown,
but the P-6014 can
support up to 4
CAT5 cameras.
IR-2400
CH
AN EL
O
N V
ISI
N
S
O
U
R
C
E
ZONE
W R
PO E
M
UTE
4
3
2
1
CAM
E
RA
CA
T
V
M
OD
O
V
L
1
2
3
4
MODEL
5
5
A0 0
O
P WER
p
Ou
Loo
t 1
p
Ou
Loo
t 1
L
Ou
t
oop 2L
Ou
t
oop 2
Lo p
ut
o O
3Lo p
ut
o O
3
op Ou 4
Lo
top Ou 4
Lo
t
M i
o
1
on t
r
M i
o
1
on t
r
Monito
r 2
Monito
r 2
R
)
I In (
Mo
n 1
R
)
I In (
Mo
n 1
IR ( o
) Ou
t M
n 2IR ( o
) Ou
t M
n 2
ow
er
P
ow
er
P
Inp
utsInp
uts
Ca
mera 1Ca
mera 1
a 2
Camer
a 2
Camer
C m ra
3
a
e
C m ra
3
a
e
a
4
Camer
a
4
Camer
V
i odeV
i ode
A i
ud
o
A i
ud
o
O
P
R
C
H
A N
N E
L
TM
I
S
I
ON
V
C
H
A N
N E
L
I
S
I
ON
V
TM
o e
l M d
-
0
1
4
P
6
entVideo Pre
sentVideo Pre
s
Cam
era 1
Cam
era 1
Camera
2Camera
2
Cam
era
3
Cam
era
3
Ca era
4mCa era
4m
S
R -23
2
S
R -23
2
Time Adj
ustTime Adj
ust
CA 5
CAMERA
SE
UENCER
T
Q
old
H
old
H
7
P-6014
RJ-45 Jack
(TIA 568A)
Camera Inputs
TV (Monitor 1)
Home Theater TV (Monitor 2)
6210
3112
Not used
Video In
2129
BNC to RCA adaptor
Audio In
RJ-45 Pin Out Diagram...
For troubleshooting purposes, it may be helpful to know the wire pin out for the
RJ-45 jacks on the P-6014. They are shown below:
Note: Only one
camera is shown,
but the P-6014 can
support up to 4
CAT5 cameras.
Connect serial data controller
to the Serial port
(Hex codes on pages 8-11)
Controlling The P-6014 Through The RS-232 Port...
The RS-232 port is the most flexible way to control the P-6014 because it
provides access to every feature on the unit. This is the preferred way for most
high-end control system to interface with devices such as the P-6014.
Pin
Signal
Gnd
Video
Gnd
N.C.
Gnd
Audio
Gnd
+12VDC
8
7
6
5
4
3
2
1
Monitor 2 Output
Pin
Signal
Gnd
Video
Gnd
IR
Gnd
Audio
Gnd
+12VDC
8
7
6
5
4
3
2
1
8 7 6 5 4 3 2 11
Monitor 1 Commands
Serial Cable Pin Out
RS-232 Control Code...
For installations requiring more sophistication the P-6014 supports RS-232
making it extremely compatible with automation systems.
Baud Rate: 19200, 8N1 (8Bit Data, No Parity, 1 Stop Bit)
Each transmission = 8 ASCII bytes
Checksum = The sum of the first 7 bytes inverted and truncated.
Note: the checksum for each command is included in the following charts.
For troubleshooting purposes, the letter z can be used in place of the
checksum character.
There are two possible responses generated when a command is received:
ack - This acknowledges that the command was received and it had a valid
checksum.
ZZZ - This means that the command was not understood or could not be
decoded correctly. It could also mean that the checksum was not valid.
P64Z1SF!
50 36 34 5A 31 53 46 21
Monitor 1, Request Status
P64Z1SR[nak]
50 36 34 5A 31 53 52 15
Monitor 1, Auto Cycle
P64Z1SN[em]
50 36 34 5A 31 53 4E 19
Monitor 1, Select Next Cam
P64Z1S43
50 36 34 5A 31 53 34 33
Monitor 1, Select Camera 4
P64Z1S34
50 36 34 5A 31 53 33 34
Monitor 1, Select Camera 3
P64Z1S25
50 36 34 5A 31 53 32 35
Monitor 1, Select Camera 2
P64Z1S16
50 36 34 5A 31 53 31 36
Monitor 1, Select Camera 1
ASCII Command
Hex Command
Function
8
P-6014 RS-232 Pins
DB-9P, Female
PC RS-232 Pins
DB-9P, Male
Monitor 2 Commands
P64Z2SF[sp]
50 36 34 5A 32 53 46 20
Monitor 2, Request Status
P64Z2SR[dc4]
50 36 34 5A 32 53 52 14
Monitor 2, Auto Cycle
P64Z2SN[can]
50 36 34 5A 32 53 4E 18
Monitor 2, Select Next Cam
P64Z2S42
50 36 34 5A 32 53 34 32
Monitor 2, Select Camera 4
P64Z2S33
50 36 34 5A 32 53 33 33
Monitor 2, Select Camera 3
P64Z2S24
50 36 34 5A 32 53 32 34
Monitor 2, Select Camera 2
P64Z2S15
50 36 34 5A 32 53 31 35
Monitor 2, Select Camera 1
ASCII Command
Hex Command
Function
9
Note: these charts contains some ASCII commands that include non-standard
ASCII characters (characters which are not included on a standard keyboard).
When programming a controller with these functions, it may be necessary to
use the Hexadecimal equivalent shown in the far right hand column.
P64ZASF[dc1]
50 36 34 5A 41 53 46 11
Global, Request Status
P64ZASR[enq]
50 36 34 5A 41 53 52 05
Global, Auto Cycle
P64ZASN[ht]
50 36 34 5A 41 53 4E 09
Global, Select Next Cam
P64ZAS4#
50 36 34 5A 41 53 34 23
Global, Select Camera 4
P64ZAS3$
50 36 34 5A 41 53 33 24
Global, Select Camera 3
P64ZAS2%
50 36 34 5A 41 53 32 25
Global, Select Camera 2
P64ZAS1&
50 36 34 5A 41 53 31 26
Global, Select Camera 1
ASCII Command
Hex Command
Function
50 36 34 5A 41 53 43 14
P64ZASC[dc4]
Global, Status Clear
Global Commands
Monitor 1 Commands
Serial Cable Pin Out
RS-232 Control Code...
For installations requiring more sophistication the P-6014 supports RS-232
making it extremely compatible with automation systems.
Baud Rate: 19200, 8N1 (8Bit Data, No Parity, 1 Stop Bit)
Each transmission = 8 ASCII bytes
Checksum = The sum of the first 7 bytes inverted and truncated.
Note: the checksum for each command is included in the following charts.
For troubleshooting purposes, the letter z can be used in place of the
checksum character.
There are two possible responses generated when a command is received:
ack - This acknowledges that the command was received and it had a valid
checksum.
ZZZ - This means that the command was not understood or could not be
decoded correctly. It could also mean that the checksum was not valid.
P64Z1SF!
50 36 34 5A 31 53 46 21
Monitor 1, Request Status
P64Z1SR[nak]
50 36 34 5A 31 53 52 15
Monitor 1, Auto Cycle
P64Z1SN[em]
50 36 34 5A 31 53 4E 19
Monitor 1, Select Next Cam
P64Z1S43
50 36 34 5A 31 53 34 33
Monitor 1, Select Camera 4
P64Z1S34
50 36 34 5A 31 53 33 34
Monitor 1, Select Camera 3
P64Z1S25
50 36 34 5A 31 53 32 35
Monitor 1, Select Camera 2
P64Z1S16
50 36 34 5A 31 53 31 36
Monitor 1, Select Camera 1
ASCII Command
Hex Command
Function
8
P-6014 RS-232 Pins
DB-9P, Female
PC RS-232 Pins
DB-9P, Male
Monitor 2 Commands
P64Z2SF[sp]
50 36 34 5A 32 53 46 20
Monitor 2, Request Status
P64Z2SR[dc4]
50 36 34 5A 32 53 52 14
Monitor 2, Auto Cycle
P64Z2SN[can]
50 36 34 5A 32 53 4E 18
Monitor 2, Select Next Cam
P64Z2S42
50 36 34 5A 32 53 34 32
Monitor 2, Select Camera 4
P64Z2S33
50 36 34 5A 32 53 33 33
Monitor 2, Select Camera 3
P64Z2S24
50 36 34 5A 32 53 32 34
Monitor 2, Select Camera 2
P64Z2S15
50 36 34 5A 32 53 31 35
Monitor 2, Select Camera 1
ASCII Command
Hex Command
Function
9
Note: these charts contains some ASCII commands that include non-standard
ASCII characters (characters which are not included on a standard keyboard).
When programming a controller with these functions, it may be necessary to
use the Hexadecimal equivalent shown in the far right hand column.
P64ZASF[dc1]
50 36 34 5A 41 53 46 11
Global, Request Status
P64ZASR[enq]
50 36 34 5A 41 53 52 05
Global, Auto Cycle
P64ZASN[ht]
50 36 34 5A 41 53 4E 09
Global, Select Next Cam
P64ZAS4#
50 36 34 5A 41 53 34 23
Global, Select Camera 4
P64ZAS3$
50 36 34 5A 41 53 33 24
Global, Select Camera 3
P64ZAS2%
50 36 34 5A 41 53 32 25
Global, Select Camera 2
P64ZAS1&
50 36 34 5A 41 53 31 26
Global, Select Camera 1
ASCII Command
Hex Command
Function
50 36 34 5A 41 53 43 14
P64ZASC[dc4]
Global, Status Clear
Global Commands
10
ASCII Command
Hex Command
Function
P64Z118Q
50 36 34 5A 31 31 38 51
Monitor 1, Cam 1, 15 Seconds
P64Z128P
50 36 34 5A 31 32 38 50
Monitor 1, Cam 2, 15 Seconds
P64Z138O
50 36 34 5A 31 33 38 4F
Monitor 1, Cam 3, 15 Seconds
P64Z148N
50 36 34 5A 31 34 38 4E
Monitor 1, Cam 4, 15 Seconds
P64Z117R
50 36 34 5A 31 31 37 52
Monitor 1, Cam 1, 10 Seconds
P64Z127Q
50 36 34 5A 31 32 37 51
Monitor 1, Cam 2, 10 Seconds
P64Z137P
50 36 34 5A 31 33 37 50
Monitor 1, Cam 3, 10 Seconds
P64Z147O
50 36 34 5A 31 34 37 4F
Monitor 1, Cam 4, 10 Seconds
P64Z116S
50 36 34 5A 31 31 36 53
Monitor 1, Cam 1, 7.5 Seconds
P64Z126R
50 36 34 5A 31 32 36 52
Monitor 1, Cam 2, 7.5 Seconds
P64Z136Q
50 36 34 5A 31 33 36 51
Monitor 1, Cam 3, 7.5 Seconds
P64Z146P
50 36 34 5A 31 34 36 50
Monitor 1, Cam 4, 7.5 Seconds
P64Z115T
50 36 34 5A 31 31 35 54
Monitor 1, Cam 1, 5 Seconds
P64Z125S
50 36 34 5A 31 32 35 53
Monitor 1, Cam 2, 5 Seconds
P64Z135R
50 36 34 5A 31 33 35 52
Monitor 1, Cam 3, 5 Seconds
P64Z145Q
50 36 34 5A 31 34 35 51
Monitor 1, Cam 4, 5 Seconds
P64Z114U
50 36 34 5A 31 31 34 55
Monitor 1, Cam 1, 4 Seconds
P64Z124T
50 36 34 5A 31 32 34 54
Monitor 1, Cam 2, 4 Seconds
P64Z134S
50 36 34 5A 31 33 34 53
Monitor 1, Cam 3, 4 Seconds
P64Z144R
50 36 34 5A 31 34 34 52
Monitor 1, Cam 4, 4 Seconds
P64Z113V
50 36 34 5A 31 31 33 56
Monitor 1, Cam 1, 3 Seconds
P64Z123U
50 36 34 5A 31 32 33 55
Monitor 1, Cam 2, 3 Seconds
P64Z133T
50 36 34 5A 31 33 33 54
Monitor 1, Cam 3, 3 Seconds
P64Z143S
50 36 34 5A 31 34 33 53
Monitor 1, Cam 4, 3 Seconds
P64Z112W
50 36 34 5A 31 31 32 57
Monitor 1, Cam 1, 2 Seconds
P64Z122V
50 36 34 5A 31 32 32 56
Monitor 1, Cam 2, 2 Seconds
P64Z132U
50 36 34 5A 31 33 32 55
Monitor 1, Cam 3, 2 Seconds
P64Z142T
50 36 34 5A 31 34 32 54
Monitor 1, Cam 4, 2 Seconds
P64Z111X
50 36 34 5A 31 31 31 58
Monitor 1, Cam 1, 1 Second
P64Z121W
50 36 34 5A 31 32 31 57
Monitor 1, Cam 2, 1 Second
P64Z131V
50 36 34 5A 31 33 31 56
Monitor 1, Cam 3, 1 Second
P64Z141U
50 36 34 5A 31 34 31 55
Monitor 1, Cam 4, 1 Second
Time Adjust Commands...
The following Time Adjust commands alter the amount of time each camera
view appears on the screen. Making time adjustments via these RS-232 will
override any physical adjustments made using the “Time Adjust” control on
the P-6014.
You can use either the global commands, which will set the time adjustment
on all the cameras, or you can use commands for the specific camera inputs.
This allows you to set different viewing times for each of the camera inputs.
For example, if camera 1 is the most important camera, you might want to set
it to show for 10 seconds, while cameras 2, 3, and 4 are set for 1 second.
These time settings will remain in the P-6014’s memory. For example, if you
send a command to switch to a specific camera view and then another
command to return back to the cycle mode, time settings for the cycle mode
will be the same as they were before you switched to the specific camera
view. Note: Any movement of the Time Adjust control will cause the unit to
enter the cycle mode and will override the time adjustment settings made via
the serial controller.
11
ASCII Command
Hex Command
Function
Monitor 2 Time Adjust Commands
P64Z218P
50 36 34 5A 32 31 38 50
Monitor 2, Cam 1, 15 Seconds
P64Z228O
50 36 34 5A 32 32 38 4F
Monitor 2, Cam 2, 15 Seconds
P64Z238N
50 36 34 5A 32 33 38 4E
Monitor 2, Cam 3, 15 Seconds
P64Z248M
50 36 34 5A 32 34 38 4D
Monitor 2, Cam 4, 15 Seconds
P64Z217Q
50 36 34 5A 32 31 37 51
Monitor 2, Cam 1, 10 Seconds
P64Z227P
50 36 34 5A 32 32 37 50
Monitor 2, Cam 2, 10 Seconds
P64Z237O
50 36 34 5A 32 33 37 4F
Monitor 2, Cam 3, 10 Seconds
P64Z247N
50 36 34 5A 32 34 37 4E
Monitor 2, Cam 4, 10 Seconds
P64Z216R
50 36 34 5A 32 31 36 52
Monitor 2, Cam 1, 7.5 Seconds
P64Z226Q
50 36 34 5A 32 32 36 51
Monitor 2, Cam 2, 7.5 Seconds
P64Z236P
50 36 34 5A 32 33 36 50
Monitor 2, Cam 3, 7.5 Seconds
P64Z246O
50 36 34 5A 32 34 36 4F
Monitor 2, Cam 4, 7.5 Seconds
P64Z215S
50 36 34 5A 32 31 35 53
Monitor 2, Cam 1, 5 Seconds
P64Z225R
50 36 34 5A 32 32 35 52
Monitor 2, Cam 2, 5 Seconds
P64Z235Q
50 36 34 5A 32 33 35 51
Monitor 2, Cam 3, 5 Seconds
P64Z245P
50 36 34 5A 32 34 35 50
Monitor 2, Cam 4, 5 Seconds
P64Z214T
50 36 34 5A 32 31 34 54
Monitor 2, Cam 1, 4 Seconds
P64Z224S
50 36 34 5A 32 32 34 53
Monitor 2, Cam 2, 4 Seconds
P64Z234R
50 36 34 5A 32 33 34 52
Monitor 2, Cam 3, 4 Seconds
P64Z244Q
50 36 34 5A 32 34 34 51
Monitor 2, Cam 4, 4 Seconds
P64Z213U
50 36 34 5A 32 31 33 55
Monitor 2, Cam 1, 3 Seconds
P64Z223T
50 36 34 5A 32 32 33 54
Monitor 2, Cam 2, 3 Seconds
P64Z233S
50 36 34 5A 32 33 33 53
Monitor 2, Cam 3, 3 Seconds
P64Z243R
50 36 34 5A 32 34 33 52
Monitor 2, Cam 4, 3 Seconds
P64Z212V
50 36 34 5A 32 31 32 56
Monitor 2, Cam 1, 2 Seconds
P64Z222U
50 36 34 5A 32 32 32 55
Monitor 2, Cam 2, 2 Seconds
P64Z232T
50 36 34 5A 32 33 32 54
Monitor 2, Cam 3, 2 Seconds
P64Z242S
50 36 34 5A 32 34 32 53
Monitor 2, Cam 4, 2 Seconds
P64Z211W
50 36 34 5A 32 31 31 57
Monitor 2, Cam 1, 1 Second
P64Z221V
50 36 34 5A 32 32 31 56
Monitor 2, Cam 2, 1 Second
P64Z231U
50 36 34 5A 32 33 31 55
Monitor 2, Cam 3, 1 Second
P64Z241T
50 36 34 5A 32 34 31 54
Monitor 2, Cam 4, 1 Second
ASCII Command
Hex Command
Function
Global Time Adjust Commands
P64ZAT8[rs]
50 36 34 5A 41 54 38 1E
Global, All Cams, 15 Seconds
P64ZAT7[us]
50 36 34 5A 41 54 37 1F
Global, All Cams, 10 Seconds
P64ZAT6[sp]
50 36 34 5A 41 54 36 20
Global, All Cams, 7.5 Seconds
P64ZAT5!
50 36 34 5A 41 54 35 21
Global, All Cams, 5 Seconds
P64ZAT4”
50 36 34 5A 41 54 34 22
Global, All Cams, 4 Seconds
P64ZAT3#
50 36 34 5A 41 54 33 23
Global, All Cams, 3 Seconds
P64ZAT2$
50 36 34 5A 41 54 32 24
Global, All Cams, 2 Seconds
P64ZAT1%
50 36 34 5A 41 54 31 25
Global, All Cams, 1 Second
10
ASCII Command
Hex Command
Function
P64Z118Q
50 36 34 5A 31 31 38 51
Monitor 1, Cam 1, 15 Seconds
P64Z128P
50 36 34 5A 31 32 38 50
Monitor 1, Cam 2, 15 Seconds
P64Z138O
50 36 34 5A 31 33 38 4F
Monitor 1, Cam 3, 15 Seconds
P64Z148N
50 36 34 5A 31 34 38 4E
Monitor 1, Cam 4, 15 Seconds
P64Z117R
50 36 34 5A 31 31 37 52
Monitor 1, Cam 1, 10 Seconds
P64Z127Q
50 36 34 5A 31 32 37 51
Monitor 1, Cam 2, 10 Seconds
P64Z137P
50 36 34 5A 31 33 37 50
Monitor 1, Cam 3, 10 Seconds
P64Z147O
50 36 34 5A 31 34 37 4F
Monitor 1, Cam 4, 10 Seconds
P64Z116S
50 36 34 5A 31 31 36 53
Monitor 1, Cam 1, 7.5 Seconds
P64Z126R
50 36 34 5A 31 32 36 52
Monitor 1, Cam 2, 7.5 Seconds
P64Z136Q
50 36 34 5A 31 33 36 51
Monitor 1, Cam 3, 7.5 Seconds
P64Z146P
50 36 34 5A 31 34 36 50
Monitor 1, Cam 4, 7.5 Seconds
P64Z115T
50 36 34 5A 31 31 35 54
Monitor 1, Cam 1, 5 Seconds
P64Z125S
50 36 34 5A 31 32 35 53
Monitor 1, Cam 2, 5 Seconds
P64Z135R
50 36 34 5A 31 33 35 52
Monitor 1, Cam 3, 5 Seconds
P64Z145Q
50 36 34 5A 31 34 35 51
Monitor 1, Cam 4, 5 Seconds
P64Z114U
50 36 34 5A 31 31 34 55
Monitor 1, Cam 1, 4 Seconds
P64Z124T
50 36 34 5A 31 32 34 54
Monitor 1, Cam 2, 4 Seconds
P64Z134S
50 36 34 5A 31 33 34 53
Monitor 1, Cam 3, 4 Seconds
P64Z144R
50 36 34 5A 31 34 34 52
Monitor 1, Cam 4, 4 Seconds
P64Z113V
50 36 34 5A 31 31 33 56
Monitor 1, Cam 1, 3 Seconds
P64Z123U
50 36 34 5A 31 32 33 55
Monitor 1, Cam 2, 3 Seconds
P64Z133T
50 36 34 5A 31 33 33 54
Monitor 1, Cam 3, 3 Seconds
P64Z143S
50 36 34 5A 31 34 33 53
Monitor 1, Cam 4, 3 Seconds
P64Z112W
50 36 34 5A 31 31 32 57
Monitor 1, Cam 1, 2 Seconds
P64Z122V
50 36 34 5A 31 32 32 56
Monitor 1, Cam 2, 2 Seconds
P64Z132U
50 36 34 5A 31 33 32 55
Monitor 1, Cam 3, 2 Seconds
P64Z142T
50 36 34 5A 31 34 32 54
Monitor 1, Cam 4, 2 Seconds
P64Z111X
50 36 34 5A 31 31 31 58
Monitor 1, Cam 1, 1 Second
P64Z121W
50 36 34 5A 31 32 31 57
Monitor 1, Cam 2, 1 Second
P64Z131V
50 36 34 5A 31 33 31 56
Monitor 1, Cam 3, 1 Second
P64Z141U
50 36 34 5A 31 34 31 55
Monitor 1, Cam 4, 1 Second
Time Adjust Commands...
The following Time Adjust commands alter the amount of time each camera
view appears on the screen. Making time adjustments via these RS-232 will
override any physical adjustments made using the “Time Adjust” control on
the P-6014.
You can use either the global commands, which will set the time adjustment
on all the cameras, or you can use commands for the specific camera inputs.
This allows you to set different viewing times for each of the camera inputs.
For example, if camera 1 is the most important camera, you might want to set
it to show for 10 seconds, while cameras 2, 3, and 4 are set for 1 second.
These time settings will remain in the P-6014’s memory. For example, if you
send a command to switch to a specific camera view and then another
command to return back to the cycle mode, time settings for the cycle mode
will be the same as they were before you switched to the specific camera
view. Note: Any movement of the Time Adjust control will cause the unit to
enter the cycle mode and will override the time adjustment settings made via
the serial controller.
11
ASCII Command
Hex Command
Function
Monitor 2 Time Adjust Commands
P64Z218P
50 36 34 5A 32 31 38 50
Monitor 2, Cam 1, 15 Seconds
P64Z228O
50 36 34 5A 32 32 38 4F
Monitor 2, Cam 2, 15 Seconds
P64Z238N
50 36 34 5A 32 33 38 4E
Monitor 2, Cam 3, 15 Seconds
P64Z248M
50 36 34 5A 32 34 38 4D
Monitor 2, Cam 4, 15 Seconds
P64Z217Q
50 36 34 5A 32 31 37 51
Monitor 2, Cam 1, 10 Seconds
P64Z227P
50 36 34 5A 32 32 37 50
Monitor 2, Cam 2, 10 Seconds
P64Z237O
50 36 34 5A 32 33 37 4F
Monitor 2, Cam 3, 10 Seconds
P64Z247N
50 36 34 5A 32 34 37 4E
Monitor 2, Cam 4, 10 Seconds
P64Z216R
50 36 34 5A 32 31 36 52
Monitor 2, Cam 1, 7.5 Seconds
P64Z226Q
50 36 34 5A 32 32 36 51
Monitor 2, Cam 2, 7.5 Seconds
P64Z236P
50 36 34 5A 32 33 36 50
Monitor 2, Cam 3, 7.5 Seconds
P64Z246O
50 36 34 5A 32 34 36 4F
Monitor 2, Cam 4, 7.5 Seconds
P64Z215S
50 36 34 5A 32 31 35 53
Monitor 2, Cam 1, 5 Seconds
P64Z225R
50 36 34 5A 32 32 35 52
Monitor 2, Cam 2, 5 Seconds
P64Z235Q
50 36 34 5A 32 33 35 51
Monitor 2, Cam 3, 5 Seconds
P64Z245P
50 36 34 5A 32 34 35 50
Monitor 2, Cam 4, 5 Seconds
P64Z214T
50 36 34 5A 32 31 34 54
Monitor 2, Cam 1, 4 Seconds
P64Z224S
50 36 34 5A 32 32 34 53
Monitor 2, Cam 2, 4 Seconds
P64Z234R
50 36 34 5A 32 33 34 52
Monitor 2, Cam 3, 4 Seconds
P64Z244Q
50 36 34 5A 32 34 34 51
Monitor 2, Cam 4, 4 Seconds
P64Z213U
50 36 34 5A 32 31 33 55
Monitor 2, Cam 1, 3 Seconds
P64Z223T
50 36 34 5A 32 32 33 54
Monitor 2, Cam 2, 3 Seconds
P64Z233S
50 36 34 5A 32 33 33 53
Monitor 2, Cam 3, 3 Seconds
P64Z243R
50 36 34 5A 32 34 33 52
Monitor 2, Cam 4, 3 Seconds
P64Z212V
50 36 34 5A 32 31 32 56
Monitor 2, Cam 1, 2 Seconds
P64Z222U
50 36 34 5A 32 32 32 55
Monitor 2, Cam 2, 2 Seconds
P64Z232T
50 36 34 5A 32 33 32 54
Monitor 2, Cam 3, 2 Seconds
P64Z242S
50 36 34 5A 32 34 32 53
Monitor 2, Cam 4, 2 Seconds
P64Z211W
50 36 34 5A 32 31 31 57
Monitor 2, Cam 1, 1 Second
P64Z221V
50 36 34 5A 32 32 31 56
Monitor 2, Cam 2, 1 Second
P64Z231U
50 36 34 5A 32 33 31 55
Monitor 2, Cam 3, 1 Second
P64Z241T
50 36 34 5A 32 34 31 54
Monitor 2, Cam 4, 1 Second
ASCII Command
Hex Command
Function
Global Time Adjust Commands
P64ZAT8[rs]
50 36 34 5A 41 54 38 1E
Global, All Cams, 15 Seconds
P64ZAT7[us]
50 36 34 5A 41 54 37 1F
Global, All Cams, 10 Seconds
P64ZAT6[sp]
50 36 34 5A 41 54 36 20
Global, All Cams, 7.5 Seconds
P64ZAT5!
50 36 34 5A 41 54 35 21
Global, All Cams, 5 Seconds
P64ZAT4”
50 36 34 5A 41 54 34 22
Global, All Cams, 4 Seconds
P64ZAT3#
50 36 34 5A 41 54 33 23
Global, All Cams, 3 Seconds
P64ZAT2$
50 36 34 5A 41 54 32 24
Global, All Cams, 2 Seconds
P64ZAT1%
50 36 34 5A 41 54 31 25
Global, All Cams, 1 Second
Channel Vision Technology will repair or replace any defect in material or workmanship which occurs
during normal use of this product with new or rebuilt parts, free of charge in the USA, for two years from
the date of original purchase. This is a no hassle warranty with no mail in warranty card needed. This
warranty does not cover damages in shipment, failures caused by other products not supplied by
Channel Vision Technology, or failures due to accident, misuse, abuse, or alteration of the equipment.
This warranty is extended only to the original purchaser, and a purchase receipt, invoice, or other proof
of original purchase date will be required before warranty repairs are provided.
Mail in service can be obtained during the warranty period by calling (800) 840-0288 toll free. A Return
Authorization number must be obtained in advance and can be marked on the outside of the shipping
carton.
This warranty gives you specific legal rights and you may have other rights (which vary from state to
state). If a problem with this product develops during or after the warranty period, please contact
Channel Vision Technology, your dealer or any factory-authorized service center.
500-199 rev D
ww w. c ha nn el v is io n .c om
234 Fischer Avenue, Costa Mesa, California 92626 USA
(714)424-6500 (800)840-0288 (714)424-6510 fax
Specifications: (typical @25º C)
P-6014
Dimensions: 5.5”W x 6.5”H x 1.5”D
Power Supply: 15VDC @ 1.6A
IR Frequency Range: 30-60kHz
Operating Temp: -10ºC to 50ºC
Audio Bandwidth: 20Hz - 20kHz
Video Crosstalk: -80dB
Video Bandwidth: DC - 20MHz
Video Crosstalk: -60dB
CAT5 Ports:
Max run length: 250ft (Camera input + Monitor output)
Max Camera Power: 12VDC @ 280mA
6210 Camera
Lens: 3.8mm
Resolution: 380 lines
S/N Ratio: More than 48dB
Min Illumination: 0.4 LUX @ F2.0
Power Consumption: 120mA
/