  • Hello! I am an AI chatbot trained to assist you with the ICM Controls ICM316C Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ICM
316
DEFROST TIMER
LII276-1
www.icmcontrols.com
800-365-5525
ICM CONTROLS
7313 William Barry Blvd.
North Syracuse, NY 13212
Input
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Power Consumption: 1 watt maximum
Output
O, X2:
– Type: Relay
– Form: DPST, normally open
– Rating: 1 amp @ 30 VAC
ODF:
– Type: Relay
– Form: SPDT, normally open
– Rating: 2 HP @ 230 VAC
Time Delays
Defrost: Fixed at 10 minutes (+/- 5%)
Interval Between Defrost:
– Pin selectable (50/70/90 minutes)
Test Time: Short across test terminals
reduces test time by 256x
Mechanical
Dimensions: 3” x 6”
Mounting:
Surface mount using (5) #6 or #8
screws, or plastic stand offs
WIRING DIAGRAM
SPECIFICATIONS
Lowcosttimeandtemperaturedefrostcontrol
Indoor
T’Stat
24
VAC
Outdoor
Fan
Compressor
RVS
HPS LPS
Aux
COM NC
Outdoor
T’Stat
Evaporator
Defrost Relay EDR
O
X2
Y
B
B
R
R
T
D
O
/