  • Hello! I am an AI chatbot trained to assist you with the ICM Controls ICM300C Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ICM
300
DEFROST TIMER
SPECIFICATIONS
Input
•Voltage: 18-30 VAC
•Frequency: 50-60 Hz
•PowerConsumption: 1 watt maximum
Output
•Ratings:
–Type: Relay –
Form: SPST, normally open
–Maximum: 1 amp
Time Delays
•Defrost: Fixed at 10 minutes (+/- 5%)
•IntervalBetweenDefrost:
– Pin selectable (30/60/90 minutes)
•ResetTimeforPowerOn: 500 ms
•TestTime: Short across test terminals
before startup to reduce time
by 256x
Mechanical
•Dimensions: 3” x 2.875”
•Mounting:
Surface mount using (4) #6 or #8
screws, or plastic standoffs
Integrates multiple time and temperature defrost functions into a
compact, open board with same footprint as Carrier 621
WIRING DIAGRAM
INSTALLATION
1. Disconnect power.
2. Connect terminals as shown in the wiring
diagram below.
3. Reapply power, check operation.
DR = Defrost Relay Coil
DFT = Defrost Thermostat
** When replacing boards with an RST
terminal, tie RST wire to common
24 VAC
24 VAC
HOLD
OUT
COM
30 60 90
TEST
** RST
Wire
DR
DFT
T’STAT