WHAT TO DO IF YOU SMELL GAS
Do not touch any electrical switch.
If you cannot reach your gas supplier,
call the fire department.
Do not try to light any appliance.
Do not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Follow the installation directions.
1.
2.
3.
4.
5.
6.
Do not store gasoline or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
If this fireplace is not properly
installed, a house fire may result.
WARNINGS & SAFETY PRECAUTIONS
3
W415-0536 / C / 09.06.06
PG2-6 INTRODUCTION
Warnings and Safety Precautions
Warranty
Dimensions
General Instructions
General Information
Care of Glass & Plated Parts
6-10 vENTING
Vent lengths

Air Terminal Locations
11-16 INSTALLATION/FRAMING
Wall & Ceiling Protection
Using Flexible Vent Components
Fireplace Vent Connection
Using Rigid Vent Components
Gas Installation
Restricting Vertical Vents
Framing
Clearance to Combustibles
Mantle Clearances and Enclosures
16 ELECTRICAL CONNECTION
Hard Wiring Connections
Schematic
17 FINISHING
Door Removal
Log Shipping Bracket
Log Placement
Glowing Embers
18 BLOWER REPLACEMENT
Night Light Replacement
19 DECORATIvE BRICK PANEL
INSTALLATION
20 AFK / WI FACE KIT
INSTALLATION
21 REMOTE AND vALvE ACCESS
Burner Assembly Removal
22-27 OPERATION / MAINTENANCE
Fireplace Operation
Hand Held Remote Operation
Operating Instructions
27 ADjUSTMENTS
Pilot Burner Adjustment
Venturi Adjustment
28-29 REPLACEMENTS
Ordering Replacement Parts
Replacement Parts
Terminal Kits
Vent Kits
Accessories
20-31 TROUBLE SHOOTING GUIDE
WARNING

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to

 
 
 
 
-


vapours and liquids.
 
 
 

 

 

Wolf Steel Ltd.
NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN.
TABLE of CONTENTS
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
4
W415-0536 / C / 09.06.06
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED
TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.
NAPOLEON products are manufactured under the strict Standard of the world recog-

NAPOLEON products are designed with superior components and materials, assembled



NAPOLEON
NAPOLEON GAS FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY


PHAZER™ logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing,


NAPOLEON will


      
NAPOLEON
are based on a predetermined rate schedule and any repair work must be done through an authorized
NAPOLEON
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer)
NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON
dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.


This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other
manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chip-
ping on porcelain enamel parts, mechanical breakage of PHAZER™ 
NAPOLEON
years NAPOLEON will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners
at 50% of the current retail price.

product has been operated in accordance with the operation instructions and under normal conditions.
 NAPOLEON may, at its discretion, fully discharge all obligations with respect
to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part,
and such expenses are not covered by this warranty.

and it shall not in any event extend to any incidental, consequential or indirect damages.
NAPOLEON with respect to the NAPOLEON
with respect to this product, its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON

      
mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer.
The warranty registration card must be returned within fourteen days to register the warranty.
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
5
W415-0536 / C / 09.06.06
   

Minimum clearance to combustible construction
from replace and vent surfaces:
f 

  
21
3
/

  
  
1
/
inches



     -

 Maximum input is 26,000 BTU/hr for both natural

-

high altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft. Maximum output for natural gas


pressure is 4.5 inches water column for natural gas and 11
inches water column for propane. Maximum inlet gas pressure
is 7 inches water column for natural gas and 13 inches water

is 3.5 inches water column for natural gas and 10 inches water
column for propane.

sitting room installations and is suitable for mobile home
installation. The natural gas model can only be installed in
a mobile home that is permanently positioned on its site and
fueled with natural gas.










  


FIGURE 1
-
 to conform with local
codes. Installation practices vary from region to region and it

for example: in Massachusetts State:
 

gas log.
A carbon monoxide detector is required in all rooms containing

The appliance off valve must be a “T” handle gas cock.
 
The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
WARNING: This product must be installed by a licensed

commonwealth of Massachusetts.
In absence of local codes, install to the current CAN/CGA
-B149 Installation Code in Canada or to the National Fuel
Gas Code, ANSI Z223.1, and NFPA 54 in the United States.
Suitable for mobile home installation if installed in accordance
with the current standard CAN/CSA Z240MH Series, for gas
equipped mobile homes, in Canada or ANSI Z223.1 and NFPA
54 in the United States.
-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig

piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig (3.5 kPa).



the full width and depth.
The optional heat circulating blower is supplied with a cord. If
installed, the junction box must be electrically connected and
grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 CANADIAN ELEC-
TRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.









GENERAL INSTRUCTIONS
GENERAL INFORMATION
22
1
/
8
"
21"
4" DIA.
7" DIA.
17
3
/
4
"
13
7
/
8
"
28"
14"
7
/
8
"
46"
58"
2"
8
7
/
8
"
28"
37
5
/
8
"
24"
5"
6
W415-0536 / C / 09.06.06
24"
16"
8"
Expansion / contraction nosies during heating up and cooling down cycles are normal and are to be expected. Change in

Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass avail-
able from your Napoleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. 
DO NOT CLEAN GLASS
WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result.
FIGURES 2A-C
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp
or American Metal Amerivent venting components.
Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp and
American Metal Amerivent venting systems must not be
combined.
Follow the installation procedure provided with the venting
components.

only the outer air intake joints must be sealed using a red high
temperature silicone (RTV). This same sealant maybe used
on both the inner exhaust and outer intake vent pipe joints
of all other approved vent systems except for the exhaust

be sealed using the black high temperature sealant Mill Pac.
A starter adaptor must be used and may be purchased from
the corresponding supplier:
 
Duravent W175-0053
Amerivent 4DSC-N2
Direct Temp 4DT-AAN
When using Napoleon venting components, use only ap-

following termination kits: WALL TERMINAL KIT GD222R, or
1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD110, 8/12 TO
12/12 ROOF TERMINAL KIT GD111, FLAT ROOF TERMINAL
KIT GD112 or PERISCOPE KIT GD201 (for wall penetration
 in conjunction with the
various terminations, use either the 5 foot vent kit GD220 or
the 10 foot vent kit GD330. These vent kits allow for either

The maximum allowable vertical vent length is 40 feet
using exible venting. The maximum number of allowable 4”
vent connections is three horizontally or vertically (exclud-


keep the vent length and number of elbows to a minimum.
FIGURE 3
CARE OF GLASS, AND PLATED PARTS
         
 or NAPOLEON RIGID
OR FLEXIBLE

vENTING
vENTING LENGTHS & AIR TERMINAL
         
 or a 

a 
FIGURES 


       





   




 






venting instruction exactly.
Deviation from the minimum vertical vent length can create

Provide a means for visually checking the vent connection to

Vent lengths that pass through unheated spaces (attics, ga-
rages, crawl spaces) should be insulated with the insulation
wrapped in a protective sleeve to minimize condensation.
The air terminal must remain unobstructed at all times. Ex-
amine the air terminal at least once a year to verify that it is
unobstructed and undamaged.
7
W415-0536 / C / 09.06.06
vertical
rise in
feet
v
T
FIGURE 4
when (H
T
) < (v
T
)
 (only one 90° elbow)
See graph to determine the required vertical rise v
T
for the
required horizontal run H
T
.

the following formulas apply:
Formula 1: H
T
< v
T
Formula 2: H
T
+ v
T
< 40 feet
Example 1:
v
1
= 3 ft
v
2
= 8 ft
v
T
=
v
1
+
v
2
=
3 + 8 = 11 ft
H
1
= 2.5 ft
H
2
= 2 ft
H
R
= H
1
+ H
2
= 2.5 + 2 = 4.5 ft
H
O
= .
03(three 90° elbows - 90°) = .03(270° - 90°) = 5.4 ft
H
T
= H
R
+ H
O
= 4.5 + 5.4 = 9.9 ft
H
T
+ v
T
= 9.9 + 11 = 20.9 ft
Formula 1: H
T
< v
T
9.9 < 11
Formula 2: H
T
+ v
T
< 40 feet
20.9 < 40

acceptable.
FIGURE 5
90°
90°
90°
H
1
v
2
H
2
v
1
horizontal vent run Plus offset in feet H
T
The shaded area within the lines represents acceptable
values for H
T
and V
T
.
for the following symbols used in the venting calculations
and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
T
- total of both horizontal vent lengths (H
R
) and offsets
(H
O
) in feet
H
R
- combined horizontal vent lengths in feet
H
O
- offset factor: .03(total degrees of offset - 90°*) in
feet
v
T
- combined vertical vent lengths in feet
feet inches
0.03 0.5
15° 0.45 6.0
30° 0.9 11.0
45° 1.35 16.0
90°* 2.7 32.0
* 
formula as 
DEFINITIONS
ELBOW vENT LENGTH vALUES
TOP EXIT / HORIzONTAL TERMINATION
8
W415-0536 / C / 09.06.06
H
2
H
1
v
1
90°
See graph to determine the required verti-
cal rise V
T
for the required horizontal run
H
T
.
v
1
= v
T
= 6 ft
H
1
= 3 ft
H
2
= 5 ft
H
R
= H
1
+ H
2
= 3 + 5 = 8 ft
H
O
= .03(two 90° elbows - 90°) = .03(18 - 90°) = 2.7 ft
H
T
= H
R
+ H
O
= 8 + 2.7 = 10.7 ft
H
T
+ v
T
=
10.7 + 6 =16.7
Formula 1: H
T
< 4.2 v
T
4.2 v
T
= 4.2 x 6 = 25.2 ft
10.7 < 25.2
Formula 2: H
T
+ v
T
< 24.75 feet
16.7 < 24.75
         -
ceptable.

following formulas apply:
Formula 1: H
T
< 4.2 v
T
Formula 2: H
T
+
T
< 24.75 feet
Example 2:
Example 3:
v
1
= 4 ft
v
2
= 1.5 ft
v
T
= v
1
+ v
2
= 4 + 1.5 = 5.5 ft
H
1
= 2 ft
H
2
= 1 ft
H
3
= 1 ft
H
4
= 1.5 ft
H
R
= H
1
+ H
2
+ H
3
+ H
4
= 2 + 1 + 1 + 1. 5 = 5.5 ft
H
O
= .03(four 90° elbows - 9) = .03(360° - 9) = 8.1 ft
H
T
= H
R
+ H
O
= 5.5 + 8.1 = 13.6 ft
H
T
+ v
T
= 13.6 + 5.5 = 19.1 ft
Formula 1: H
T
< 4.2 v
T
4.2 v
T
= 4.2 x 5.5 = 23.1 ft
13.6 < 23.1
Formula 2: H
T
+ v
T
< 24.75 feet
19.1 < 24.75

acceptable.
FIGURE 6
FIGURE 7
required
vertical
rise in
inches
v
T
horizontal vent run Plus offset in feet H
T
FIGURE 8
H
2
H
4
v
2
90°
H
3
H
1
v
1
90°
The shaded area within the lines represents acceptable
values for H
T
and V
T
.
when (H
T
) > (v
T
)

TOP EXIT / HORIzONTAL TERMINATION
9
W415-0536 / C / 09.06.06
required vertical
rise in feet
v
T
horizontal vent run Plus offset in
feet
H
T
when (H
T
) < (v
T
)
FIGURE 9
      
90° elbow (top exit) or one 90° elbow (rear exit), the
following formulas apply:
Formula 1: H
T
< v
T
Formula 2: H
T
+ v
T
< 40 feet
See graph to
determine the
required vertical rise
v
T
for the required
horizontal run H
T
.
TOP EXIT vERTICAL TERMINATION
The shaded area within the lines represents ac-
ceptable values for H
T
and V
T
.
maximum
vertical
rise in
feet
v
T
horizontal vent run Plus offset in feet
H
T
The shaded area within the lines represents acceptable
values for H
T
and V
T
.
See graph to determine the required vertical rise v
T
for the
required horizontal run H
T
.
FIGURE 11
v
3
= 1.5 ft
v
T
=
v
1
+
v
2
+
v
3
=
2 + 1 + 1.5 = 4.5 ft
H
1
= 6 ft
H
2
= 2 ft
H
R
= H
1
+ H
2
= 6 + 2 = 8 ft
H
O
= .03(four 90° elbows - 90°)
= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft
H
T
= H
R
+ H
O
= 8 + 8.1 = 16.1 ft
H
T
+ v
T
= 16.1 + 4.5 = 20.6 ft
Formula 1: H
T
< 3v
T
3v
T
=
3 x
4.5 = 13.5 ft
16.1 > 13.5

acceptable.
Formula 2: H
T
+ v
T
< 40 feet
20.6 < 40
        
        

formulas.
FIGURE 10
H
1
H
2
v
3
v
1
90°
90°
90°
v
2
90°
when (H
T
) > (v
T
)

TOP vERTICAL TERMINATION
    
(top exit) or one 90° elbow (rear exit), the following formulas
apply:
Formula 1: H
T
< 3v
T
Formula 2: H
T
+ v
T
< 40 feet
Example 7:
v
1
= 2 ft
v
2
= 1 ft
10
W415-0536 / C / 09.06.06
FIGURE 12
11
W415-0536 / C / 09.06.06
This application occurs
when venting through
a roof. Installation kits
for various roof pitches
are available from your
Napoleon dealer. See
Accessories to order the

1. Determine the air
terminal location, cut
and frame 9½ or 11½
inch openings in the ceil-
ing and the roof to provide the minimum clearance between

center the exhaust pipe location midway between two joist to
prevent having to cut them. Use a plumb bob to line up the
center of the openings.
DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL.
A vent pipe shield will
prevent any materi-
als such as insulation,

space around the pipe.
Nail headers between
the joist for extra sup-
port.
2. Apply a bead of
caulking (not supplied) to the framework or to the Wolf Steel


must be placed on the bottom of each framed opening in a
roof or ceiling that the venting system passes through. Apply

the vent shield to restrict cold air from being drawn into the

shield maintain the required clearance to combustibles. Once
the vent pipe / liner is installed

between the pipe / liner and the

3. In the attic, after the pipe /
liner has been installed, slide the
vent pipe collar down to cover up
the open end of the shield and
tighten. This will prevent any
materials, such as insulation,
      
around the pipe.
INSTALLATION
WALL AND CEILING PROTECTION
vERTICAL INSTALLATION
FIGURE 15
FIGURE 14
11
11
FIGURE 13
This application occurs when venting through an exterior
wall. Having determined the air terminal location, cut and
frame a hole in an exterior wall with a minimum rectangle
opening of 12” x 11”.


1. Assemble the shield to the spacer as shown, using the
3 shorter screws supplied.
The shield is meant to protect combustible materials within
the wall. If the shield is deeper than the combustible portion


spacer over the framework to restrict cold air from being drawn
into the room or around the stove. Ensure that both spacer
and shield maintain the required clearance to combustibles.
Secure the spacer in place using the 4 longer screws sup-


HORIzONTAL INSTALLATION



HORIZONTAL TERMINATION:




12
W415-0536 / C / 09.06.06



1. Fasten the roof support to the
roof using the screws provided.
The roof support is optional. In
this case the venting is to be ad-
equately supported using either an
alternate method suitable to the
authority having jurisdiction or the
optional roof support. (Fig.a)
2. Stretch the inner aluminum

Slip the liner a minimum of 2” over the inner sleeve of the
air terminal connector and secure
with 3 #8 screws. Seal using a
heavy bead of the high temperature
sealant. (Fig.b)
3. Repeat using the outer aluminum

4. Thread the air terminal connector
/ liner assembly down through
the roof. The air terminal must
be located vertically and plumb.
Attach the air terminal connector to
the roof support, ensuring that the
top of the air terminal is 16” above
the highest point that it penetrates
the roof. (Fig.c) If the attic space is
   
the Wolf Steel vent pipe collar or
  onto the air


wall and make weather tight by
5. Apply a heavy bead of the
high temperature sealant, (W573-
0007 not provided), to the inside of
the 4” liner approximately 1” from
the end. Slip the liner a minimum

and secure with 3 #8 screws.
6. 
aluminium liner,
apply sealant,
slide a mini-
mum of 2” over
the fireplace
combustion air
collar and se-
cure with 3 #8
screws.
1. Cut or frame a hole in an exterior wall with a minimum
round or square opening of 11
1
/
2
W x 11
1
/
2
H. Secure the

Secure the terminal to the terminal extension plate if required
The cover plate of the GD-222R terminal is
13”x13” and will cover the 11 1/2” x 11 1/2” opening but if the
opening is made any larger - the terminal extension plate is
required.
2.   
required length taking into account the additional length

of 2” over the inner sleeve of the air terminal and secure with
3 #8 screws. Apply a heavy bead of the high temperature
sealant.
3.
the outer combustion air sleeve of the air terminal and secure
with 3 #8 screws. Seal as before.
4.        
required clearance to combustibles. Secure to the exterior
4
7
7
FIGURE 18
      

  


USING FLEXIBLE vENT COMPONENTS
HORIzONTAL AIR TERMINAL INSTALLATION
  






vERTICAL AIR TERMINAL INSTALLATION
FIGURE 19a,b&c
ROOF SUPPORT
a
DO NOT CLAMP THE
FLEXIBLE

AIR
TERMINAL
CONNECTOR
INNER FLEX
LINER
OUTER FLEX
LINER
INNER
SLEEVE
HIGH
TEMPERATURE
SEALANT
b
STORM COLLAR
FLASHING
CAULKING
WEATHER
SEALANT
2”
AIR INLET
BASE
c
CAULKING
SCREWS
#10x2"
PIPE
7" FLEX
2" OVERLAP
4"FLEX
PIPE
SEALANT
SEALANT
HI-TEMP
TERMINAL
EXTENSION
PLATE
CAULKING
FIGURE 17
5. Remove nails from the
shingles, above and to the
sides of the chimney. Place
    
terminal connector leaving a
min. 3/4” of the air terminal
connector showing above


sides and upper edge of
the shingles. Ensure that
the air terminal connector
is properly centred within
    
margin all around. Fasten to
the roof. Do not nail through
the lower portion of the



6. Aligning the seams of the terminal and air terminal
connector, place the terminal over the air terminal connector
making sure the liner goes into the hole in the terminal.
Secure with the three screws provided. (Fig.c)
7. Apply a heavy bead of weatherproof caulking 2 inches
        
between the air inlet base and the storm collar. Install the
storm collar around the air terminal connector and slide
down to the caulking. Tighten to ensure that a weather-tight
seal between the air terminal connector and the collar is
achieved. (Fig.c)
13
W415-0536 / C / 09.06.06
The vent system must be supported approximately every 3
feet for both vertical and horizontal runs. Use Wolf Steel vent
spacers or equivalent every 3 feet and either side of each
elbow to maintain the minimum 1¼” clearance between the
outer and inner vent pipes. Use Wolf Steel support ring as-
sembly or equivalent noncombustible strapping to maintain
the minimum clearance to combustibles for both vertical and
horizontal runs.
        

    

        
1. -
place into position.
Measure the vent
length required
between terminal
  -
ing into account
the additional
length needed for
the finished wall
surface and any
1¼” overlaps between venting components.
2. Apply high temperature sealant (W573-0007 not pro-

        
tapping screws. Repeat using 7” piping.
3. 
top and the lettering in an upright, readable position) insert
the terminal into both vent pipes with a twisting motion to
ensure that both the terminal sleeves engage into the vent
pipes and sealant. Secure the terminal to the exterior wall and
make weather tight by sealing with caulking (not supplied).
1.       

joint and screw holes using the high temperature sealant
(W573-0007 not provided).
2.       

FIREPLACE vENT CONNECTION
USING RIGID vENT COMPONENTS
HORIzONTAL AIR TERMINAL INSTALLATION
EXTENDED HORIzONTAL AIR TERMINAL
INSTALLATION
FIGURE 20
1. Follow the instructions
for “Horizontal Air Terminal
Installations”, items 1 to 3.
2. Continue adding com-
ponents alternating inner
and outer venting. Ensure
that all 4” venting and elbows

attached and each compo-
nent is securely fastened to
the one prior. Attach the 4”
telescopic sleeve to the vent
run.
Repeat using a 7” telescopic sleeve. Secure and seal as
before. To facilitate completion, attach 4” and 7” couplers to
the air terminal.
3. Install the air terminal. See item 3 of the Horizontal Air
-
nect to the air terminal assembly. Fasten with self tapping
screws and seal. Repeat using the 7” telescopic sleeve.
HI-TEMP
SEALANT
7" PIPE
2" OVERLAP
4" PIPE
CAULKING
SCREWS
#10x2½"
CAULKING
SEALANT
HI-TEMP
FIGURE 21
VENTING
TELESCOPIC SLEEVE
20"
COUPLER
AIR TERMINAL
FIGURE 22
14
W415-0536 / C / 09.06.06
FLUE COLLAR
RESTRICTOR PLATE
TOP OF THE
FIREBOX



1.


2. The access to the gas inlet is
located on the right side of the outer
shell.
3.      
must all be within the outer shell.
4.-
port the gas valve so that the lines
are not bent.
5. Check for gas leaks by brushing
on a soap and water solution. Do not

1. 
2. Fasten the roof support to the roof using the screws
provided. The roof support is optional. In this case the vent-
ing is to be adequately supported using either an alternate
method suitable to the authority having jurisdiction or the
optional roof support.
3. Apply high temperature seal-
ant to the outer edge of the inner
sleeve of the air terminal. Slip a 4”
diameter coupler a minimum of 2”
over the sleeve and secure using
3 screws.
4 Apply high temperature seal-
ant to the outer edge of the of the
outside sleeve of the air terminal.
Slip a 7” diameter coupler over
the sleeve and secure as before.
Trim the 7” coupler even with the
4” coupler end.
5 Thread the air terminal pipe
assembly down through the roof
support and attach, ensuring that
a minimum 16” of air terminal will
penetrate the roof when fastened.
The air terminal must be located
vertically and plumb.
6. Remove nails from the shin-
gles, above and to the sides of
   
over the air terminal and slide it
underneath the sides and upper edge of the shingles. Ensure
-
ing a 3/4” margin all around. Fasten to the roof. Do NOT nail

by sealing with caulking. Where possible, cover the sides and

7. Apply a heavy bead of waterproof caulking 2 inches
-
minal connector and down to the caulking. Tighten to ensure
that a weather-tight seal between the air terminal and the
collar is achieved.
 Continue adding rigid venting sections, sealing and
securing as above. Attach a 4” collapsed telescopic pipe to
the last section of rigid piping. Secure with screws and seal.
Repeat using a 7” telescopic pipe.
 Run a bead of high temperature sealant around the

pipe a minimum of 2” onto the collar. Secure with 3 screws.
Repeat with the 7” telescopic pipe.
10. In the attic, slide the vent pipe collar down to cover up
the open end of the shield and tighten. This will prevent any

around the pipe.
VENT PIPE
SHIELD
VENT
PIPE
COLLAR
FIGURE 24
FIGURE 23
vERTICAL vENTING INSTALLATION GAS INSTALLATION

appearance is not desirable, the vent exit must be restricted
using restrictor plate, W500-0205. This reduces the velocity
 
creating a more traditional appearance.
The plate has a series of holes to allow for adjustment.
Remove the two screws on either side of the exhaust collar

then replace the screws.
It is recommend to secure in the third set of holes which
causes the greatest amount of restriction for vent length
between 15 and 30 feet.
RESTRICTING vERTICAL vENTS
FIGURE 25
FIGURE 26
FIGURE 27
22
1
/
8
"
21"
4" DIA.
7" DIA.
17
3
/
4
"
13
7
/
8
"
28"
14"
7
/
8
"
46"
58"
2"
8
7
/
8
"
28"
33
5
/
8
"
STORM COLLAR
FLASHING
CAULKING
WEATHER
SEALANT
2”
AIR INLET
BASE
15
W415-0536 / C / 09.06.06
WARNING
Facing and/or finishing
material must never
overhang into the fireplace
opening.
Do not distort or force the frame
kit components.
When using a rough finish materi-
al (i.e.; stone), maintain a ¼” - ½”
border from the framing
components.
NON-COMBUSTIBLE
FINISHING MATERIAL
59
3
/
8
"
21
3
/
4
"
32"
4"
4"
STUD
2"
FIRESTOP
SPACER
COMBUSTIBLE
MATERIAL
2"
SPACER
STAND OFF
NON-COMBUSTIBLE
72"
24"
62
1
/
8
"
29"
44"
1"
MIN
1"
MIN
29"
22
1
/
2
"
2 FT.
MIN
10"
MIN
58
1
/
2
"
72"
2
9"
22
1
/
2
"
FIGURE 31
FRAMING
CLEARANCE TO COMBUSTIBLES
MAINTAIN THESE MINIMUM CLEARANCES TO COM-
BUSTIBLES:
Fireplace framing - 0” to stand-offs (top, rear & sides)
Fireplace finishing - 4” to sides of fireplace opening.
- 21
3
/
4
” to top of fireplace opening.
FIGURE 28
FIGURE 29
FIGURE 30
It is best to frame your fireplace after it is positioned and the
vent system is installed. Use 2x4’s and frame to local build-
ing codes.
Note: In order to avoid the possibility of exposed insulation
or vapour barrier coming in contact with the fireplace body,
it is recommended that the walls of the fireplace enclosure
be “finished” (ie: drywall/sheetrock), as you would finish any
other outside wall of a home. This will ensure that clearance
to combustibles is maintained within the cavity.
It is not necessary to install a hearth extension, but the fire-
place should be raised to be flush with either the hearth or
the finished floor.
When roughing in the fireplace, raise the fireplace to accom-
modate for the thickness of the finished floor materials, i.e.
tile, carpeting, hard wood, which if not planned for will interfere
with the removal of the hearth strip, which must be removed
to access the firebox.
Objects placed in front of the fireplace should be kept a mini-
mum of 48” away from the front face.
For convenience, the stand-offs have been shipped flat.
Before framing, ensure the stand-offs are opened and
screwed in place.
IMPORTANT:
The Park Ave. requires
a minimum inside enclo-
sure height of 72”.
For temperature require-
ments, this area must be
left unobstructed.
It is recommended that
the enclosure be ventilat-
ed at the top and bottom
to circulate the hot air.
Non-combustible
finishing material
(ie: cement board,
brick, stone, tile)
may be used to fin-
ish the front of the
unit.
16
W415-0536 / C / 09.06.06
FIGURE 32
MANTLE CLEARANCES
0
3 4 7
8
9
11
13
1 2 5 6
7
10
12
H
E
I
G
H
T
M
A
N
T
L
E
MANTLE WIDTH
Combustible mantle clearance
can vary according to the man-
tle depth. Use the graph to
help evaluate the clearance
needed.
          

     


BEFORE IN
STALLATION






accordance with local codes. In the absence of local codes,
use the current CSA C22.1 CANADIAN ELECTRICAL CODE
in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRI-
CAL CODE in the United States.
ELECTRICAL CONNECTION
HARD WIRING CONNECTION
SCHEMATIC
IN
OUT
O
F
F
P
I
L
O
T
O
N
AUXILIARY
DEVICE
FAN
L2
L1
[HOT]
TP
TH
AUX
FAN LINE
VALVE
MOTOR AUTO MAN
GAS
FIGURE 33
STUD
2"
FIRESTOP
SPACER
COMBUSTIBLE
MATERIAL
2"
5"
3"
2"
6"
INSULATION
SLEEVE
1" GAP FROM INSULATION SLEEVE
2" GAP FROM VENTING
4"
TOP OF
UNIT
TOP OF
FIREPLACE
OPENING
11"
12"
10"
9"
8"
SPACER
STAND OFF
17
W415-0536 / C / 09.06.06
4. Place log #4 with the
charred branch facing
inward. Position the pin
in log #4 into the hole
on the right of log #2.
5. Place log #5 so
the locating hole on
the botttom of the log
sits on the screw and
spacer.
6. Finally, align the
rectangular peg on log
#6 with the notch on
the front right portion
of the burner.
Optional Front
Glass Door
Latches
Retainer
Before the glass door can be removed, the optional front
must be removed.

Pull the handles of the latches forward, then lift the hooks out
from the slots in the door frame to release the top of the door.
Next, pivot forward until the top edge of the door clears the

the door out from the retainer along the bottom of the door.
LOG SHIPPING

-
ping brackets. Lift up to remove.
LOG SHIPPING BRACKET
DOOR REMOvAL
FINISHING


LOG PLACEMENT
PHAZER
TM
logs, exclusive to Napoleon Fireplaces, provide
a unique and realistic glowing effect that is different in every
installation.
1. Place the rear log #1
onto the locating studs
along the back edge of
the PHAZERAMIC
burner.
2. Position log #2 in the
2 locating holes behind
the andirons.
3. Place log #3, with
the charred branch fac-
ing inward. Position the
pin in log #3 into the
hole on the left of the
log #2.
GLOWING EMBERS
2
3
1
FIGURE 36 A-F
FIGURE 34
FIGURE 35
Glowing embers are NOT recommended. The burner has
been designed to achieve maximum glow without embers.
18
W415-0536 / C / 09.06.06
BLOWER
MOUNTING
PLATE
REMOVE 4 SCREWS
BLOWER REPLACEMENT
The Napoleon PARK AVENUE comes equipped with a heat
circulating blower. The blower is pre-wired and is controlled by
the remote control supplied with the unit. For control details,
see operation. Pg. 22.





1.
2. Turn off the gas valve.
3. Remove the glass door, logs, rear log supports, brick
-
port bracket.
4. The blower mounting plate can now be removed. Remove

5.
connectors before attempting to remove the blower from the

 Remove the two screws securing the blower and lift through
blower access opening.
FIGURE 37
REMOVE 2 SCREWS
Your PARK AVENUE comes equipped with our “Night Light”.
The light has been pre-wired and is controlled from the
remote control.
If in the event the lamp or lens needs to be replaced, follow
the instructions below.
Unplug the wireharness
/ transformer from the
junction box inside the

NIGHT LIGHT REPLACEMENT
SCREWS
LENSE
FRAME
FIREBOX TOP
FIGURE 40
Remove the four screws that secure the lens frame.
This frame retains the glass lens. The lamp can now be
accessed.
Note: 

The lamp will pull straight out of the socket. Replace with
Wolf Steel parts only, as lamp and lens are special “high
temperature” products.
When re-installing, ensure integrity of gasket seal.





FIGURE 39
FIGURE 41
AMBER SIDE UP
GASKET
LENSE
FRAME
Note: When re-installing the replace-
ment blower, it will be necessary to
replace the gasket (W290-0104) on
the blower mounting plate.
FIGURE 38
19
W415-0536 / C / 09.06.06
1. Carefully remove the glass door and all logs. (Refer to
the installation manual)
2. Remove the two screws holding the front portion of the
. Remove the pilot shield by removing the
two screws as illustrated. (Fig. 42)
3. Remove the 3 screws holding
the burner down and carefully
remove the burner. (Fig. 43)
4. Install the right brick panel by sliding the bottom edge of
dge

with the brick retainers. (Fig. 44)
Note: Due to the brittle material of the bricks, care must
be taken not to bend or force them into place.
Note: Refractory panels require a 24 hour curing period
on a low ame.
32
1
HERRINGBONE PATTERN ILLUSTRATED



        
       

STEP
#3
5. Rest the bottom edge of the rear panel on top
           
         
held in place when both side panels are in position.
6. Install the left brick panel using the same method
described in step 4.

STEP
#2
PILOT SHIELD
DECORATIvE BRICK PANEL INSTALLATION
FIGURE 42
FIGURE 43
FIGURE 44
FIGURE 45
20
W415-0536 / C / 09.06.06
1. Attach screw and spacer as illustrated in Fig. 46 to the
bottom of both sides of the front housing.
2. Attach the face plate bracket provided to the top edge
of the front housing using 2 #8 - 1/2” truss head screws as
illustrated in Fig. 47.
3. Lift and hook the faceplate over the spacers. Then
push the top of the faceplate back until it comes in contact
with the face plate bracket, then secure on the underside
by using the 2 1/4-20 screws provided as illustrated in Fig.
49.
SCREW
&
SPACER
NOTE: A 1/4” gap must be maintained between
the front and all nishing material due to regular
removal.
AFK / WI FACE KIT INSTALLATION
FIGURE 47
FIGURE 46
FIGURE 48
FIGURE 49
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

NAPOLEON GD82NT User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI