Operating instructions
Betriebsanleitung
Mode d‘emploi
Manual de instrucciones
EN
DE
FR
ES
Models TR12-B, TC12-B Models TR12-M, TC12-MModels TR12-A, TC12-A
Resistance thermometer TR12 and thermocouple TC12
Widerstandsthermometer TR12 und Thermoelement TC12
Sonde à résistance TR12 et thermocouple TC12
Termorresistencia TR12 y termopar TC12
EN
DE
FR
ES
2
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12
Operating instructions models TR12 and TC12
Page
3 - 28
Betriebsanleitung Typen TR12 und TC12
Seite
29 - 54
Mode d'emploi types TR12 et TC12
Page
55 - 80
Manual de instrucciones modelos TR12 y TC12
Página
81 - 105
© 08/2013 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA
®
is a registered trademark in various countries.
WIKA
®
ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 3
Contents
Contents
1. General information 4
2. Design and function 4
3. Safety 8
4. Transport, packaging and storage 11
5. Commissioning, operation 12
6. Faults 17
7. Maintenance, cleaning and calibration 19
8. Dismounting, return and disposal 20
9. Specifications 21
10. Accessories 27
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC124
1. General information
The thermometers described in the operating instructions have been manufactured
using state-of-the-art technology.
These operating instructions contain important information on handling the instrument.
Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety
regulations for the instrument’s range of use.
Skilled personnel must have carefully read and understood the operating instructions
prior to beginning any work.
Subject to technical modifications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TE 60.16 (TR12-A)
TE 60.17 (TR12-B, TR12-M)
TE 65.16 (TC12-A)
TE 65.17 (TC12-B, TC12-M)
- Application consultant:
Tel.: +49 9372 132-0
Fax: +49 9372 132-406
info@wika.com
Abbreviations
RTD Resistance temperature detector”; resistance thermometer
TC Thermocouple
2. Design and function
2.1 Description
The model TR12-B (resistance thermometer) and model TC12-B (thermocouple) electrical
thermometers consist of a module (TR12-M, TC12-M) which is built into a case. The
module is made up of a spring-loaded measuring insert (TR12-A, TC12-A) built into a neck
tube. The measuring insert (TR12-A, TC12-A) is replaceable.
The active measuring component of the measuring insert is manufactured from a welded
tube or from mineral-insulated cable, optionally in combination with ceramic-insulated
thermocouple wires. The sensor is embedded in ceramic powder, heat-resistant potting
compound, cement compound or thermally conductive paste.
1. General information / 2. Design and function
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 5
If the temperature sensor is designed as a grounded thermocouple, the thermocouple
is joined directly to the sheath. Versions with a diameter smaller than 3 mm and with
grounded thermocouples should be considered as galvanically connected with earth
potential.
The connection side of the measuring insert consists of a transition sleeve with connected
bare wires.
This document describes standard versions of instruments. For applications in hazardous
areas special instrument designs are required.
For further information for operation in hazardous areas, see the additional information for
the corresponding ignition protection type (separate document).
CAUTION!
Damage to the instrument
To avoid damage to the instrument, thermometers of this model range must
be installed with a thermowell.
Select a suitable thermowell (any type of thermowell can be selected) and
take the operational process data (temperature, pressure, density and
flow velocity) into account.
The use of special designs without thermowell is possible, but is the
responsibility of the operator.
Possible sensor measuring ranges:
Model TR12: -200 ... +600 °C
Model TC12: -40 ... +1,200 °C
The following mounting and operating information has been compiled with care. However, it
is not possible to consider all potential usage cases.
2. Design and function
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC126
2.2 Technical description of the three variants
Legend:
Neck tube
Thread to the thermowell
Measuring insert
Thread to the connection head
A(U
2
) Insertion length
(tapered thread)
A(L
1
) Insertion length
(parallel thread)
NL Nominal length
N(M
H
) Neck length
tapered
thread
parallel
thread
14013854.02
parallel
thread
tapered
thread
fabricated neck tube
(neck tube welded)
“nipple-union-nipple”
neck tube
tapered thread
parallel thread with
counter nut
TR12-B, TC12-B
Variant 1
TR12-B, TC12-B
Variant 2
TR12-B, TC12-B
Variant 3
Thread
TR12-M, TC12-M
Module
Thread
Thread Thread Thread
Legend:
Connection head
Neck tube
Connection to thermowell
Measuring insert
Terminal block
Transmitter (option)
Field transmitter
14039769.01
T
max
= +80 °C
T
max
= +150 °C
T
max
= +300 °C
T
max
= undefined
2.3 Neck tube versions
2. Design and function
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 7
2.4 Case- and connection heads
The dimensions of the case- and connection heads are given in the respective data sheet.
2.5 Tightening torques
Connection head, selectable (example)
Thread Tightening torques in Nm
Connection head material
Aluminium Stainless steel
1/2 NPT 32 35
3/4 NPT 36 40
M20 x 1.5, with counter nut
1)
23 25
M24 x 1.5, with counter nut
1)
27 30
Tightening torques between connection head and neck tube
Tightening torques for connection to thermowell
Tightening torques for connection to neck tube
1) only for versions with fabricated neck tube
Thread Tightening torques in Nm
R 1/2
1)
50 ... 60
Thread Tightening torques in Nm
1/2 NPT 35
3/4 NPT 40
G 1/2 B 35
G 3/4 B 40
M14 x 1.5 25 ... 30
M18 x 1.5 35
M20 x 1.5 35 ... 40
M27 x 2 40 ... 45
Only ever screw in, or unscrew, the instrument via the spanner flats and to the
prescribed torque using an appropriate tool.
The correct torque depends on the dimensions of the connection thread and the sealing
used (form/material).
When screwing in or unscrewing the instrument, do not use the connection head as
contact surface.
When screwing in the instrument, please observe that the threads are not skewed.
2.6 Scope of delivery
Cross-check scope of delivery with delivery note.
2. Design and function
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC128
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury
or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or
damage to property or the environment, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result in burns, caused
by hot surfaces or liquids, if not avoided.
Information
... points out useful tips, recommendations and information for efficient and
trouble-free operation.
3.2 Intended use
These resistance thermometers and thermocouples are used for temperature
measurement in industrial applications. They can be combined with a variety of thermowell
designs, but the operational process data (temperature, pressure, density and flow
velocity) must be taken into account. Operation without thermowell is only recommended
in certain applications. The replaceable, centrically spring-loaded measuring insert and
its extended spring travel enable combination with the widest range of connection head
designs.
Neither repairs nor structural modifications are permitted, and any would void the
guarantee and the respective certification. The manufacturer shall not be responsible for
constructional modifications after delivery of the instruments.
The instrument has been designed and built solely for the intended use described here,
and may only be used accordingly.
The technical specifications contained in these operating instructions must be observed.
The manufacturer shall not be liable for claims of any type based on operation contrary to
the intended use.
3. Safety
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 9
3.3 Responsibility of the operator
The system operator is responsible for selecting the thermometer or thermowell, and for
the selection of their materials, so as to guarantee their safe operation within the plant or
machine. When preparing a quote, WIKA can only give recommendations which are based
on our experience in similar applications.
The safety instructions within these operating instructions, as well as the safety, accident
prevention and environmental protection regulations for the application area must be
maintained.
The operator is obliged to maintain the product label in a legible condition.
3.4 Personnel qualification
WARNING!
Risk of injury should qualification be insufficient
Improper handling can result in considerable injury and damage to
equipment.
The activities described in these operating instructions may only be
carried out by skilled electrical personnel who have the qualifications
described below.
Skilled electrical personnel
Skilled electrical personnel are understood to be personnel who, based on their technical
training, know-how and experience as well as their knowledge of country-specific
regulations, current standards and directives, are capable of carrying out work on
electrical systems and independently recognising and avoiding potential hazards. The
skilled electrical personnel have been specifically trained for the work environment they
are working in and know the relevant standards and regulations. The skilled electrical
personnel must comply with current legal accident prevention regulations.
Operating personnel
The personnel trained by the operator are understood to be personnel who, based on their
education, knowledge and experience, are capable of carrying out the work described and
independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive
media.
3. Safety
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC1210
3.5 Labelling, safety marks
Product label (example)
Model
A = measuring insert
B = process thermometer
M = basic module
Serial number
Approval-related data
Year of manufacture
Information on version (measuring element, measuring range...)
Sensor in accordance with standard (resistance thermometer)
- F =
Thin-film measuring resistor
- W = Wire-wound measuring resistor
Sensor in accordance with standard (thermocouple)
- ungrounded = ungrounded welded
- grounded = welded to the sheath (grounded)
- quasi grounded = The thermometer is, due to its low insulation clearances between
resistance sensor and sheath, to be considered as grounded.
Transmitter model (only for design with transmitter)
Before mounting and commissioning the instrument, ensure you
read the operating instructions!
TR12-M-IDBZ
1 x Pt100 / A / 3 (F) -50 ... +500 °C
Um = DC 30 V / Pm = 2 W
BVS 07 ATEX E 071 X
IECEx BVS 11.0042X
II 2 G Ex db IIC T* Gb
EN 60751
0158
WIKA Alexander Wiegand SE & Co.KG, D-63911 Klingenberg
Made in Germany 2013
WARNING: DO NOT OPEN WHILE ENERGIZED!
11012345
TC12-M-IDBZ
1 x Typ K / 1 / . 0 ... +600 °C
Um = DC 30 V / Pm = 2 W
BVS 07 ATEX E 071 X
IECEx BVS 11.0042X
II 2 G Ex db IIC T* Gb
EN 60584-1
0158
WIKA Alexander Wiegand SE & Co.KG, D-63911 Klingenberg
Made in Germany 2013
WARNING: DO NOT OPEN WHILE ENERGIZED!
11012345
TR12-B-IDBZ
1 x Pt100 / A / 3 (F) -50 ... +500 °C
Um = DC 30 V / Pm = 2 W
BVS 07 ATEX E 071 X
IECEx BVS 11.0042X
II 2 G Ex db IIC T* Gb
EN 60751
0158
WIKA Alexander Wiegand SE & Co.KG, D-63911 Klingenberg
Made in Germany 2013
WARNING: DO NOT OPEN WHILE ENERGIZED!
11012345
TC12-B-IDBZ
1 x Typ K / 1 / . 0 ... +600 °C
Um = DC 30 V / Pm = 2 W
BVS 07 ATEX E 071 X
IECEx BVS 11.0042X
II 2 G Ex db IIC T* Gb
EN 60584-1
0158
WIKA Alexander Wiegand SE & Co.KG, D-63911 Klingenberg
Made in Germany 2013
WARNING: DO NOT OPEN WHILE ENERGIZED!
11012345
3. Safety
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 11
4. Transport, packaging and storage
4.1 Transport
Check the instrument for any damage that may have been caused by transport.
Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, a high level of damage to property can occur.
When unloading packed goods upon delivery as well as during internal
transport, proceed carefully and observe the symbols on the packaging.
With internal transport, observe the instructions in chapter 4.2 “Packaging
and storage”.
If the instrument is transported from a cold into a warm environment, the formation of
condensation may result in instrument malfunction. Before putting it back into operation,
wait for the instrument temperature and the room temperature to equalise.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Permissible conditions at the place of storage:
Storage temperature:
Instruments without built-in transmitter: -40 ... +80 °C
Instruments with built-in transmitter: see operating instructions of the transmitter in
question
Humidity: 35 ... 85 % relative humidity (non-condensing)
Avoid exposure to the following factors:
Direct sunlight or proximity to hot objects
Mechanical vibration, mechanical shock (putting it down hard)
Soot, vapour, dust and corrosive gases
Hazardous environments, flammable atmospheres
Store the instrument in its original packaging in a location that fulfils the conditions listed
above. If the original packaging is not available, pack and store the instrument as described
below:
1. Place the instrument, along with shock-absorbent material, in the packaging.
2. If stored for a prolonged period of time (more than 30 days), place a bag containing a
desiccant inside the packaging.
4. Transport, packaging and storage
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC1212
5. Commissioning, operation
WARNING!
Damage to the measuring instrument by operation outside the upper
or lower limits of the operating temperature
Failure to observe the permissible operating temperature, also taking
into account convection and radiation, can even cause damage to the
thermometer during mounting.
The upper and lower limits of the specified operating temperature range
must not be exceeded.
During installation, take care to
Avoid distorting the cable sheath when tightening the pressure screw.
Avoid cutting too deep into the cable sheath.
Use suitable cable.
Be careful of the clamping area of the cable gland.
Thermometers must be earthed if dangerous voltages could be expected at the
connection wires (caused, for example, by mechanical damage, electrostatic charge or
induction)!
The protection class is not valid with armoured cables (stainless steel sheathed).
Seals should be checked for signs of brittleness and, if necessary, replaced.
5.1 Removal and installation of the measuring insert
The bare wires have a cross-section of approx. 0.22 mm², are 150 mm long and are colour-
coded dependent upon the sensor type. The measuring insert is secured against twisting.
Before removing the measuring insert, fully disconnect the
electrical connections to the terminal block or transmitter.
After that, the neck tube can be loosened and unscrewed from the head.
5. Commissioning, operation
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 13
Removed measuring insert with neck tube:
To disconnect the measuring insert
from the neck tube, loosen the M16
bolt at the top end of the neck tube
and unscrew it.
5. Commissioning, operation
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC1214
The installation of the measuring insert is carried out in
the reverse order (clean the measuring insert prior to
installation).
The hexagonal crimped tip of the measuring insert is
guided by the screw-in of the hexagonal socket screw.
Tightening torque of the screw: 12 ... 14 Nm
5.2 Electrical mounting
Cable glands
Requirements for meeting ingress protection:
Only use cable glands within their indicated clamping area (cable diameter suitable for
the cable gland).
Do not use the lower clamping area with very soft cable types.
Only use round cables (if necessary, slightly oval in cross-section).
Do not twist the cable.
Repeated opening/closing is possible; however only if necessary, as it might have a
detrimental effect on the ingress protection
For cables with a pronounced cold-flow behaviour the screw connection must be fully
tightened.
5.3 Electrical connection
CAUTION!
Danger of short circuit
Damage to cables, wires and connection points can lead to malfunction of
the instrument.
Avoid damaging the cables and wires.
Fine-stranded leads with bare ends must be finished with end splices
(cable preparation).
Both the internal effective capacitance and inductance must be
considered.
The electrical connection is to be made according to the following sensor connections/
pin assignments.
5. Commissioning, operation
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 15
5.3.1 Resistance thermometer
With terminal block
With connection cable
3160629.06
red
1 x Pt100, 2-wire 1 x Pt100, 3-wire 1 x Pt100, 4-wire
white white
red
red
red
red
white
white
white
white
white
white
red
red
red
red
red
2 x Pt100, 2-wire
2 x Pt100, 3-wire
2 x Pt100, 4-wire
red
white
white
red
red
white
black
yellow
yellow
yellow
black
black
white
white
red
red
red
red
black
black
black
black
yellow
yellow
yellow
red
white
black
yellow
white
1 x Pt100
2-wire
1 x Pt100
3-wire
1 x Pt100
4-wire
2 x Pt100
2-wire
2 x Pt100
3-wire
red
red
red
red
red
red
red
red
white
white
white
white
white
white
black
black
black
yellow
yellow
3160629.06
5. Commissioning, operation
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC1216
5.3.2 Thermocouples
With terminal block
With connection cable
Colour coding of cable strands
Sensor type Standard Positive Negative
K IEC 60584 Green White
J IEC 60584 Black White
E IEC 60584 Violet White
N IEC 60584 Pink White
Variant 1
For the electrical specifications (e.g. connection diagrams, tolerance values, etc.), see
chapter 6.1 “Electrical connection” or the data sheets TE 60.17 (for TR12) and TE 65.17
(for TC12).
Variant 2
For the electrical specifications (e.g. connection diagrams, tolerance values, etc.) please
refer to the relevant operating instructions and/or data sheet for the built-in head-mounted
transmitter.
Variant 3
For the electrical specifications (e.g. connection diagrams, tolerance values, etc.) please
refer to the relevant operating instructions and/or the relevant data sheet for the built-in field
transmitter.
Single thermocouple Dual thermocouple
The colour coding
at the positive poles
of the instrument
decides the
correlation of polarity
and terminal.
3166822.03
Single thermocouple Dual thermocouple
5. Commissioning, operation
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 17
Variant 1 and 2
Junction between cable gland and connection head
M20 x 1.5 thread: Tightening torques 12 Nm
½ NPT thread: Tightening torques 30 Nm
Junction between cable and cable gland
Screw the pressure screw tightly into the adapter (use appropriate tools!)
6. Faults
CAUTION!
Physical injuries and damage to property and the environment
If faults cannot be eliminated by means of the listed measures, the instrument
must be taken out of operation immediately.
Ensure that there is no longer any signal present and protect against being
put into operation accidentally.
Contact the manufacturer.
If a return is needed, please follow the instructions given in chapter 8.2
“Return”.
WARNING!
Physical injuries and damage to property and the environment caused
by hazardous media
Upon contact with hazardous media (e.g. oxygen, acetylene, flammable
or toxic substances), harmful media (e.g. corrosive, toxic, carcinogenic,
radioactive), and also with refrigeration plants and compressors, there is a
danger of physical injuries and damage to property and the environment.
Should a failure occur, aggressive media with extremely high temperature
and under high pressure or vacuum may be present at the instrument.
For these media, in addition to all standard regulations, the appropriate
existing codes or regulations must also be followed.
Wear the required protective equipment (depending on the application; the
thermometer itself is basically not dangerous).
For contact details see chapter 1 “General information” or the back page of
the operating instructions.
5. Commissioning, operation / 6. Faults
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC1218
Faults Causes Measures
No signal/cable break Mechanical load too high or
overtemperature
Replace probe or measuring insert
with one of a suitable design
Erroneous measured
values
Sensor drift caused by
overtemperature
Replace probe or measuring insert
with one of a suitable design
Sensor drift caused by
chemical attack
Use a suitable thermowell.
Erroneous measured
values (too low)
Entry of moisture into cable
or measuring insert
Replace probe or measuring insert
with one of a suitable design
Erroneous measured
values and response
times too long
Wrong mounting geometry,
for example mounting depth
too deep or heat dissipation
too high
The temperature-sensitive area
of the sensor must be inside the
medium, and surface measurements
must be ungrounded
Deposits on the sensor or
thermowell
Remove deposits
Erroneous measured
values (of thermocouples)
Parasitic voltages (thermal
voltages, galvanic voltage) or
wrong equalisation line
Use suitable compensating cable
Temporary or sporadic
interruptions of the
measured value signal
Cable break in connection
cable or loose contact
caused by mechanical
overload
Replace probe or measuring insert
with a suitable design, for example
equipped with a bend protection
spring or a thicker conductor cross-
section
Corrosion Composition of the medium
not as expected or modified
or wrong thermowell material
selected
Analyse medium and then select a
more suitable material or replace
thermowell regularly
Signal interference Stray currents caused by
electric fields or earth circuits
Use shielded connection leads, and
increase the distance to motors and
power cables
Earth circuits Eliminate potential differences by
using galvanically isolated barriers
or transmitters
6. Faults
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC12 19
7. Maintenance, cleaning and calibration
For contact details see chapter 1 “General information” or the back page of
the operating instructions.
7.1 Maintenance
The thermometers described here are maintenance-free.
Repairs must only be carried out by the manufacturer.
7.2 Cleaning
CAUTION!
Physical injuries and damage to property and the environment
Improper cleaning may lead to physical injuries and damage to property and
the environment. Residual media in the dismounted instrument can result in a
risk to persons, the environment and equipment.
Carry out the cleaning process as described below.
1. Prior to cleaning, disconnect the electrical connections properly.
2. Use the required protective equipment (depending on the application; the thermometer
itself is basically not dangerous).
3. Clean the instrument with a moist cloth.
This applies in particular to thermometers with a case made of plastic to ensure that any
risk of electrostatic charge is avoided.
Electrical connections must not come into contact with moisture!
CAUTION!
Damage to the instrument
Improper cleaning may lead to damage to the instrument!
Do not use any aggressive cleaning agents.
Do not use any hard or pointed objects for cleaning.
4. Wash or clean the dismounted instrument, in order to protect persons and the
environment from exposure to residual media.
7.3 Calibration, recalibration
It is recommended that the measuring insert is recalibrated at regular intervals (resistance
thermometers: approx. 24 months, thermocouples: approx. 12 months). This period can
reduce, depending on the particular application. The calibration can be carried out by the
manufacturer, as well as on site by qualified skilled personnel with calibration instruments.
7. Maintenance, cleaning and calibration
EN
14064370.02 08/2018 EN/DE/FR/ES
WIKA operating instructions models TR12, TC1220
8. Dismounting, return and disposal
8.1 Dismounting
WARNING!
Physical injuries and damage to property and the environment
through residual media
Upon contact with hazardous media (e.g. oxygen, acetylene, flammable
or toxic substances), harmful media (e.g. corrosive, toxic, carcinogenic,
radioactive), and also with refrigeration plants and compressors, there is a
danger of physical injuries and damage to property and the environment.
Before storage of the dismounted instrument (following use) wash or
clean it, in order to protect persons and the environment from exposure to
residual media.
Use the required protective equipment (depending on the application; the
thermometer itself is basically not dangerous).
Observe the information in the material safety data sheet for the
corresponding medium.
Only disconnect the thermometer once the system has been depressurised.
WARNING!
Risk of burns
During dismounting there is a risk of dangerously hot media escaping.
Let the instrument cool down sufficiently before dismounting it!
8.2 Return
Strictly observe the following when shipping the instrument:
All instruments delivered to WIKA must be free from any kind of hazardous substances
(acids, bases, solutions, etc.) and must therefore be cleaned before being returned.
WARNING!
Physical injuries and damage to property and the environment
through residual media
Residual media in the dismounted instrument can result in a risk to persons,
the environment and equipment.
With hazardous substances, include the material safety data sheet for the
corresponding medium.
Clean the instrument, see chapter 7.2 “Cleaning”.
When returning the instrument, use the original packaging or a suitable transport packaging.
To avoid damage:
1. Place the instrument, along with shock-absorbent material, in the packaging.
Place shock-absorbent material evenly on all sides of the transport packaging.
2. If possible, place a bag containing a desiccant inside the packaging.
3. Label the shipment as carriage of a highly sensitive measuring instrument.
8. Dismounting, return and disposal
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI