RuggedCom RSG2488 Installation guide

Type
Installation guide
RUGGEDCOM RSG2488
Installation Guide
April 5, 2013
www.RuggedCom.com
RUGGEDCOM RSG2488
Installation Guide
ii
Copyright © 2013 RuggedCom Inc.
All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized
except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or
trademark registration.
This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be
photocopied, reproduced or translated to another language without the prior written consent of RuggedCom Inc.
Disclaimer Of Liability
RuggedCom has verified the contents of this manual against the hardware and/or software described. However, deviations between the
product and the documentation may exist.
RuggedCom shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing,
performance, or use of this material.
The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We
appreciate any suggested improvements. We reserve the right to make technical improvements without notice.
Registered Trademarks
RuggedServer™, RuggedWireless™, RuggedCom Discovery Protocol (RCDP)™, RuggedExplorer™, Enhanced Rapid Spanning Tree
Protocol (eRSTP)™, ROX™, Rugged Operating System On Linux™, RuggedBackbone™, CrossBow™ and eLAN™ are trademarks of
RuggedCom Inc. Rugged Operating System (ROS)® and RuggedSwitch® are registered trademarks of RuggedCom Inc.
Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the
owner.
Contacting RuggedCom
Corporate Headquarters US Headquarters Europe Headquarters
RuggedCom Inc.
300 Applewood Crescent
Concord, Ontario
Canada, L4K 5C7
Toll-free: 1 888 264 0006
Tel: +1 905 856 5288
Fax: +1 905 856 1995
RuggedCom
1930 Harrison St., Suite 209
Hollywood, Florida
USA, 33020
Toll-free: 1 888 264 0006
Tel: +1 954 922 7938 ext. 103
Fax: +1 954 922 7984
RuggedCom
Unit 41, Aztec Centre,
Aztec West, Almondsbury, Bristol
United Kingdom, BS32 4TD
Tel: +44 1454 203 404
Fax: +44 1454 203 403
Web: www.RuggedCom.com
RUGGEDCOM RSG2488
Installation Guide
RUGGEDCOM RSG2488
iii
Table of Contents
Preface ................................................................................................................ v
Alerts .................................................................................................................................................. v
Related Documents ............................................................................................................................. v
Accessing Documentation ................................................................................................................... vi
Training .............................................................................................................................................. vi
Customer Support .............................................................................................................................. vi
Chapter 1
Introduction .......................................................................................................... 1
1.1 Feature Highlights ........................................................................................................................ 1
1.2 Configuration Ports and Indicator LEDs ......................................................................................... 1
Chapter 2
Installing the Device ............................................................................................ 3
2.1 Mounting the Device .................................................................................................................... 3
2.1.1 Mounting the Device to a Rack .......................................................................................... 4
2.1.2 Mounting the Device on a DIN Rail .................................................................................... 5
2.1.3 Mounting the Device to a Panel ......................................................................................... 5
2.2 Installing/Removing Power Supplies .............................................................................................. 6
2.2.1 Installing the Power Supplies ............................................................................................. 7
2.2.2 Removing the Power Supplies ........................................................................................... 7
2.2.3 Wiring Power Supply Terminal Blocks ................................................................................. 8
2.3 Connecting the Failsafe Alarm Relay ........................................................................................... 10
2.4 Grounding the Device ................................................................................................................. 11
2.5 Cabling Recommendations ......................................................................................................... 11
2.5.1 Protection On Twisted-Pair Data Ports .............................................................................. 12
2.5.2 Gigabit Ethernet 1000Base-TX Cabling Recommendations ................................................. 12
2.6 Connecting to the Device ........................................................................................................... 13
Chapter 3
Modules .............................................................................................................. 15
3.1 Available Modules ...................................................................................................................... 15
3.2 Installing/Removing Modules ....................................................................................................... 17
3.2.1 Installing Modules ............................................................................................................ 17
3.2.2 Removing Modules .......................................................................................................... 18
RUGGEDCOM RSG2488
RUGGEDCOM RSG2488
Installation Guide
iv
3.3 Installing/Removing SFP Optical Ports ......................................................................................... 18
3.3.1 Installing an SFP Optical Port .......................................................................................... 19
3.3.2 Removing an SFP Optical Port ......................................................................................... 19
Chapter 4
Technical Specifications ..................................................................................... 21
4.1 Power Supply Specifications ....................................................................................................... 21
4.2 Failsafe Relay Specifications ...................................................................................................... 21
4.3 Port Specifications ...................................................................................................................... 22
4.4 Supported Networking Standards ................................................................................................ 23
4.5 Operating Environment ............................................................................................................... 23
4.6 Mechanical Specifications ........................................................................................................... 24
4.7 Pin Assignments ........................................................................................................................ 24
Chapter 5
Dimension Drawings .......................................................................................... 27
Chapter 6
Certification ........................................................................................................ 31
6.1 Agency Approvals ...................................................................................................................... 31
6.2 FCC Compliance ........................................................................................................................ 31
6.3 EMI and Environmental Tests ..................................................................................................... 32
RUGGEDCOM RSG2488
Installation Guide
Preface
Alerts v
Preface
This guide describes the RUGGEDCOM RSG2488. It describes the major features of the device, installation,
commissioning and important technical specifications.
It is intended for use by network technical support personnel who are responsible for the installation,
commissioning and maintenance of the device. It is also recommended for use by network and system planners,
system programmers, and line technicians.
Alerts
The following types of alerts are used when necessary to highlight important information.
DANGER!
DANGER alerts describe imminently hazardous situations that, if not avoided, will result in death or
serious injury.
WARNING!
WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/or
equipment damage.
CAUTION!
CAUTION alerts describe hazardous situations that, if not avoided, may result in equipment damage.
IMPORTANT!
IMPORTANT alerts provide important information that should be known before performing a procedure
or step, or using a feature.
NOTE
NOTE alerts provide additional information, such as facts, tips and details.
Related Documents
Other documents that may be of interest include:
ROS User Guide for RSG2488
Preface
RUGGEDCOM RSG2488
Installation Guide
vi Accessing Documentation
Accessing Documentation
The latest Hardware Installation Guides and Software User Guides for most RuggedCom products are available
online at www.RuggedCom.com. Software User Guides for previous releases are also available.
For any questions about the documentation or for assistance finding a specific document, contact a RuggedCom
Sales representative.
Training
RuggedCom offers a wide range of educational services ranging from in-house training of standard courses
on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs,
experience and application.
RuggedCom's Educational Services team thrives on providing our customers with the essential practical skills to
make sure users have the right knowledge and expertise to understand the various technologies associated with
critical communications network infrastructure technologies.
RuggedCom's unique mix of IT/Telecommunications expertise combined with domain knowledge in the
utility, transportation and industrial markets, allows RuggedCom to provide training specific to the customer's
application.
For more information about training services and course availability, visit www.RuggedCom.com or contact a
RuggedCom Sales representative.
Customer Support
Customer support is available 24 hours, 7 days a week for all RuggedCom customers. For technical support or
general information, please contact Customer Support at:
Toll Free (North America): 1 866 922 7975
International: +1 905 856 5288
Online: www.RuggedCom.com
RUGGEDCOM RSG2488
Installation Guide
Chapter 1
Introduction
Feature Highlights 1
Introduction
The RSG2488 is a utility grade, fully managed, industrial Ethernet switch designed to operate reliably in harsh
environments. With rugged metal enclosure and an optional conformal coating, the RSG2488 provides a high
level of immunity to electromagnetic interference and heavy electrical surges, and can withstand temperatures
between -40 and 85 °C (-40 and 185 °F).
Highly modular, the RSG2488 switch supports up to 28 electrical and/or optical interfaces with data transfer rates
of 10/100/1000 Mbit/s. This makes it the ideal industry-standard switch for constructing electrical and/or optical
line, ring and star topologies.
Section 1.1
Feature Highlights
Simple plug and play operation with automatic learning, negotiation and crossover detection
MSTP 802.1Q-2005
RSTP (802.1w) and Enhanced Rapid SpanningTree (eRSTP™) network fault recovery (<1ms)
Quality of service (802.1p) for real-time traffic
VLAN (802.1Q) with double tagging
Port rate limiting and broadcast storm limiting
Port configuration, status, statistics, mirroring, security
SNTP time synchronization (client and server)
Web-based, Telnet and CLI management interfaces
SNMP (Simple Network Management Protocol) v1/v2/v3 (56-bit encryption)
Rich set of diagnostics with logging and alarms
Section 1.2
Configuration Ports and Indicator LEDs
The RSG2488 features various ports and indicator LEDs on the front panel for configuring and troubleshooting
the device.
Chapter 1
Introduction
RUGGEDCOM RSG2488
Installation Guide
2 Configuration Ports and Indicator LEDs
2 3 511
4
6
Figure 1: Front Panel
1. Power Module Indicator LEDs 2. RS232 Serial Console Port 3. Management Port 4. Alarm Indicator LED 5. MicroSD Port
6. Port Status Indicator LEDs
RS232 Serial Console Port This port is for interfacing directly with the device and access initial management functions.
Management Port This 10/100Base-T Ethernet port is used for system management that is out-of-band from
the switch fabric.
Alarm Indicator LED The alarm indicator LED illuminates when an alarm condition exists.
Power Module Indicator LEDs These LEDs indicate the status of the power modules. The top LED indicates the power
supply is supplying power. The bottom LED indicates the power supply is receiving power.
Port Status Indicator LEDs These LEDs indicate when ports are active.
MicroSD Port This port houses the microSD card containing the firmware and configuration for the device.
RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Mounting the Device 3
Installing the Device
This section describes how to install the device, including mounting the device, installing/removing modules,
connecting power, and connecting the device to the network.
WARNING!
Radiation hazard — risk of serious personal injury. This product contains a laser system and is
classified as a CLASS 1 LASER PRODUCT. Use of controls or adjustments or performance of
procedures other than those specified herein may result in hazardous radiation exposure.
WARNING!
Electrocution hazard — risk of serious personal injury. Before performing any maintenance tasks,
make sure all power to the device has been disconnected and wait approximately 2 minutes for any
remaining energy to dissipate.
IMPORTANT!
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall
render all warranties null and void.
Changes or modifications not expressly approved by RuggedCom Inc. could invalidate specifications,
test results, and agency approvals, and void the user's authority to operate the equipment.
IMPORTANT!
This product should be installed in a restricted access location where access can only be gained by
service personnel or users who have been instructed about the reasons for the restrictions applied to
the location and about any precautions that shall be taken; and access is through the use of a tool or
lock and key, or other means of security, and is controlled by the authority responsible for the location.
Section 2.1, “Mounting the Device”
Section 2.2, “Installing/Removing Power Supplies”
Section 2.3, “Connecting the Failsafe Alarm Relay”
Section 2.4, “Grounding the Device”
Section 2.5, “Cabling Recommendations”
Section 2.6, “Connecting to the Device”
Section 2.1
Mounting the Device
The RSG2488 is designed for maximum mounting and display flexibility. It can be ordered with connectors that
allow it to be installed in a 48 cm (19 in) rack, 2.5 cm (1 in) DIN rail, or directly on a panel.
Chapter 2
Installing the Device
RUGGEDCOM RSG2488
Installation Guide
4 Mounting the Device to a Rack
NOTE
For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to
Chapter 5, Dimension Drawings.
The following sections describe the various methods of mounting the device:
Section 2.1.1, “Mounting the Device to a Rack”
Section 2.1.2, “Mounting the Device on a DIN Rail”
Section 2.1.3, “Mounting the Device to a Panel”
Section 2.1.1
Mounting the Device to a Rack
For rack mount installations, the RSG2488 can be ordered with rack mount adaptors pre-installed at the front or
rear of the chassis. Additional adaptors are provided to further secure the device in high-vibration or seismically
active locations.
To secure the device to a standard 48 cm (19 in) rack, do the following:
1. Make sure the rack mount adaptors are installed on the correct side of the chassis.
To make the modules and ports accessible, install the rack mount adaptors at the rear of the chassis
To make the management ports and LEDs accessible, install the rack mount adaptors at the front of the
chassis
NOTE
The chassis features multiple mounting holes, allowing the rack mount adaptors to be installed up
to 25 mm (1 in) from the face of the device.
33
21
Figure 2: Rack Mount Adaptors
1. Rear 2. Front 3. Rack Mount Adaptor
2. If required, install adaptors on the opposite side of the device to protect from vibrations.
3. Insert the device into the rack.
NOTE
Since heat within the device is channeled to the enclosure, it is recommended that 1 rack-unit
of space, or 44 mm (1.75 in), be kept empty above the device. This allows a small amount of
convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
4. Secure the adaptors to the rack using the supplied hardware.
RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Mounting the Device on a DIN Rail 5
Section 2.1.2
Mounting the Device on a DIN Rail
For panel installations, the RSG2488 can be ordered with panel/DIN rail adaptors pre-installed on each side of
the chassis. The adaptors allow the device to be attached to a panel using screws.
To mount the device to a panel, do the following:
1. Align the adaptors with the DIN rails and slide the device into place.
3
1
1
2
2
Figure 3: DIN Rail Mounting
1. DIN Rail 2. Panel/DIN Rail Adaptor 3. Screw
2. Install one of the supplied screws on either side of the device to secure the adaptors to the DIN rails.
Section 2.1.3
Mounting the Device to a Panel
For panel installations, the RSG2488 can be ordered with panel/DIN rail adaptors pre-installed on each side of
the chassis. The adaptors allow the device to be attached to a panel using screws.
To mount the device to a panel, do the following:
1. Place the device against the panel and align the adaptors with the mounting holes.
Chapter 2
Installing the Device
RUGGEDCOM RSG2488
Installation Guide
6 Installing/Removing Power Supplies
2
1
1
Figure 4: Panel Mounting
1. Screw 2. Panel/DIN Rail Adaptor
2. Install the supplied screws to secure the adaptors to the panel.
Section 2.2
Installing/Removing Power Supplies
The RSG2488 supports dual redundant AC and/or DC power supplies that can be installed in any combination.
IMPORTANT!
In a high AC/DC and low DC (24/48 V) power supply arrangement, either power supply can be
installed in slot PM1 or PM2. However, if a high AC/DC power supply is installed in slot PM1, the
high AC/DC wiring must be connected to the high terminal block PM1 terminals. If a low DC power
supply is installed in slot PM1, the loww DC wiring must be made to the low terminal block PM1
terminals. High voltage wiring is always made to the upper Hi terminal block and low voltage (24/48
V) wiring is always made to the lower Lo terminal block.
Use only #16 gauge wiring when connecting terminal blocks.
A circuit breaker rated no higher than 20 A must be installed between the device and the supply
mains.
Whenever possible, use a separate circuit breaker for each power supply.
For maximum redundancy in a dual power supply configuration, use two independent power
sources.
RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Installing the Power Supplies 7
The socket outlet/disconnect device must be installed near the device and be easily accessible.
Equipment must be installed according to applicable local wiring codes and standards.
The following sections describe how to install, remove and wire the power supplies:
Section 2.2.1, “Installing the Power Supplies”
Section 2.2.2, “Removing the Power Supplies”
Section 2.2.3, “Wiring Power Supply Terminal Blocks”
Section 2.2.1
Installing the Power Supplies
To install the power supplies, do the following:
1. Make sure power to the device has been disconnected and wait approximately two minutes for any
remaining energy to dissipate.
2. Remove the dust cover or, if equipped, the currently installed power supply. For information about removing
power supplies, refer to Section 2.2.2, “Removing the Power Supplies”.
3. Insert the power supply into the empty slot.
2
3
1
Figure 5:
1. Screws 2. Power Supply 3. Slot
4. Hand-tighten the screws to secure the module.
5. If necessary, connect the required terminal block to the chassis. For more information, refer to Section 2.2.3,
“Wiring Power Supply Terminal Blocks”.
6. Supply power to the device. The top and bottom LEDs on the power supply should be green, indicating that
power is being received and supplied to the device.
Section 2.2.2
Removing the Power Supplies
To remove the power supplies, do the following:
Chapter 2
Installing the Device
RUGGEDCOM RSG2488
Installation Guide
8 Wiring Power Supply Terminal Blocks
1. Make sure power to the device has been disconnected and wait approximately two minutes for any
remaining energy to dissipate.
2. Unscrew the power supply(ies) from the chassis.
3. Pull the power supply(ies) from the chassis.
2
3
1
Figure 6:
1. Screws 2. Power Supply 3. Slot
4. Install a cover(s) over the empy slot to prevent the ingress of dust and dirt.
Section 2.2.3
Wiring Power Supply Terminal Blocks
The RSG2488 can be equipped with screw-type or insulated terminal blocks for high or low AC/DC power input.
Connect the terminal blocks to the HI and LO terminal ports on the rear face of the device.
2
1
Figure 7: Terminal Ports
1. LO Input 2. HI/HIP Input
NOTE
The screw-type terminal block is installed using Philips screws and compression plates, allowing either
bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable screws, which
must be removed to make connections.
RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Wiring Power Supply Terminal Blocks 9
CAUTION!
Electrical hazard — risk of damage to the device. Do not connect AC power cables to a DC power
supply terminal block. Damage to the power supply may occur.
Connectors for Power Modules
WARNING!
Electrocution hazard — risk of serious personal injury and/or damage to the device. Make sure the
supplied cover is always installed over the HI/HIP terminal block.
43
2
43
1
Figure 8: Power Supply Terminal Blocks
1. Insulated Terminal Block for HIP Power Modules 2. Screw-Type Terminal Block for HI Power Modules 3. Connectors for HI and HIP
Power Modules 4. Connectors for 24, 24P, 48, and 48P Power Modules
Wiring Examples
+
Figure 9: Single AC Power Supply Wiring
+
+
Figure 10: Dual AC Power Supply Wiring
Chapter 2
Installing the Device
RUGGEDCOM RSG2488
Installation Guide
10 Connecting the Failsafe Alarm Relay
+
Figure 11: Single DC Power Supply Wiring
+
Figure 12: Dual DC Power Supply Wiring
+
+
Figure 13: Dual AC/DC Power Supply Wiring
Section 2.3
Connecting the Failsafe Alarm Relay
The failsafe relay is provided to identify criticial error conditions. The contacts are energized when the device is
powered-up and remain energized unless a critical error occurs.
The following shows the proper relay connections.
RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Grounding the Device 11
3
2
1
Figure 14: Failsafe Alarm Relay Wiring
1. Normally Open 2. Common 3. Normally Closed
Control of the failsafe relay output is configurable through the Rugged Operating System (ROS) software. One
common application for this relay is to signal an alarm if a power failure.
Section 2.4
Grounding the Device
The RSG2488 chassis ground connection uses a #6-32 screw. It is recommended to terminate the ground
connection with a #6 ring or spade lug and torque it to 1.7 Nm (15 lbf-in).
3
1
2
Figure 15: Chassis Ground Connection
1. #6-32 Screw 2. Stainless Steel Standoff 3. #6 Ring Lug
Section 2.5
Cabling Recommendations
Before connecting the device, be aware of the recommendations and considerations outlined in the following
sections:
Section 2.5.1, “Protection On Twisted-Pair Data Ports”
Chapter 2
Installing the Device
RUGGEDCOM RSG2488
Installation Guide
12 Protection On Twisted-Pair Data Ports
Section 2.5.2, “Gigabit Ethernet 1000Base-TX Cabling Recommendations”
Section 2.5.1
Protection On Twisted-Pair Data Ports
RuggedCom does not recommend the use of copper cabling of any length for critical, real-time substation
automatation applications. All copper Ethernet ports on RuggedCom products include transient suppression
circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class
1 standards. This means that during a transient electrical event, communications erorrs or interruptions may
occur, but recovery is automatic.
RuggedCom also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
Section 2.5.2
Gigabit Ethernet 1000Base-TX Cabling Recommendations
The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet communications over distances of
up to 100 m (328 ft) using all 4 pairs in category 5 (or higher) balanced, unshielded twisted-pair cabling. For
wiring guidelines, system designers and integrators should refer to the Telecommunications Industry Association
(TIA) TIA/EIA-568-A wiring standard that characterizes minimum cabling performance specifications required
for proper Gigabit Ethernet operation. To ensure reliable, error-free data communication, new and pre-existing
communication paths should be verified for TIA/EIA-568-A compliance.
The following table summarizes the relevant cabling standards:
Table 1: Cabling Categories and 1000Base-TX Compliance
Cabling Category
1000Base-
TX Compliant
Required Action
< 5 No New wiring infrastructure required.
5 Yes Verify TIA/EIA-568-A compliance.
5e Yes No action required. New installations should be designed with Category 5e or higher.
6 Yes No action required.
> 6 Yes Connector and wiring standards to be determined.
Follow these recommendations for copper data cabling in high electrical noise environments:
Data cable lengths should be as short as possible, preferrably 3 m (10 ft) in length. Copper data cables should
not be used for inter-building communications.
Power and data cables should not be run in parallel for long distances, and should be installed in separate
conduits. Power and data cables should intersect at 90° angles when necessary to reduce inductive coupling.
Shielded/screened cabling can be used when required. The cable shield should be grounded at one single
point to avoid the generation of ground loops.
RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Connecting to the Device 13
Section 2.6
Connecting to the Device
The RS232 serial console port on the front of the RSG2488 device provides access to the boot-time control and
configuration menu interface, as well as a console connection to the ROS™ Web interface.
1
Figure 16: Serial Console Port
1. RS232 Serial Console Port
Use the following settings when attempting to connect to the device through the serial console port:
57600 bps
8 bits
No parity
1 stop bit
Chapter 2
Installing the Device
RUGGEDCOM RSG2488
Installation Guide
14 Connecting to the Device
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

RuggedCom RSG2488 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI