Sensor Access X-PIN is a single door controller that uses a PIN code for access control. It can be connected to a door contact and request to exit button to allow the system to send a signal to a sounder in case the door has been forced open or left open. The X-PIN has a maximum relay current of 2A, and its input voltage ranges from 12VDC to 24VDC or 12VAC to 24VAC. It has two 3-colored LED indicators and meets IP64 standards for outdoor usage.

Sensor Access X-PIN is a single door controller that uses a PIN code for access control. It can be connected to a door contact and request to exit button to allow the system to send a signal to a sounder in case the door has been forced open or left open. The X-PIN has a maximum relay current of 2A, and its input voltage ranges from 12VDC to 24VDC or 12VAC to 24VAC. It has two 3-colored LED indicators and meets IP64 standards for outdoor usage.

XPIN&XPROX
InstallGuide
www.sensoraccess.co.uk
 XPINXPROX
InputVoltage
VDC12vDC24vDC12vDC24vDC
VAC12vDC24vAC16vDC24vAC
Maximum
InputCurrent
(12vDC)
HeaterOn130mA145mA
HeaterOff610mA625mA
StandbyIn
putCurrent
(12vDC)
HeaterOn70mA85mA
HeaterOff550mA365mA
MaximumRelayCurrent2A2A
REXInputNormallyOpenNormallyOpen
AuxInputNormallyOpenNormallyOpen
MaxProximityRead
RangeN/A65mm
ProximityCardCompati
bilityN/ASPSHL,SPISO,
SPKEY,SPDISC
LEDIndicatorsTwo3Coloured
LED
Two3Coloured
LED
OperatingTemperatures‐20°Cto60°C‐20°Cto60°C
OutdoorUsageMeetsIP64MeetsIP64
Dimensions120mm(H)x76mm(W)x22mm(D)
Weight521g
TheXPINisasingledoorcontrollerwhichusesPINonly.TheXPROXisasingle
doorcontrollerthatusesPINandproximitytechnology.Allelectronicsarewithin
thehousingofthereader.TheXPINandXPROXcanbeconnectedtoadoorcon
tactandrequesttoexitbuttontoallowthesystemtosendasignaltoasounderin
casethedoorhasbeenforcedorleftopen.
XPIN&XPROX
InstallGuide
www.sensoraccess.co.uk
MODESOFOPERATION
NormalMode(Default)
Modeindicatorisgreen.
Innormalmode,thedoorislockeduntilavalidprimarycodeispresentedtothecontroller.Thecontrollercan
onlybeprogrammedinnormalmode.
SecureMode
Modeindicatorisred.
Onlysecureandmasteruserscanaccessthepremisesinsecuremode.
USERLEVELS
TheXPIN&XPROXAccessControlunitsacceptupto500usersandprovideentryviatheuseofcodesorcards.
NormalUser‐Anormaluseronlyhasaprimarycodeandisgrantedaccessonlywhenthecontrollerisinitsnor
malorbypassmode
SecureUser‐Asecureusermusthaveaprimaryandsecondarycodeassigned,andthetwocodesmustnotbe
thesame.(pleaseseeUserManualformoreinformation)
ColourDescription
RedVInput
BlackGround
GreenREX/BL
WhiteIn/Monitor
PurpleLock:Com
GreyLock:N.O.
BrownLock:N.C.
BlueAux:Com
YellowAux:N.O.
OrangeAux:N.C.
XPIN&XPROX
InstallGuide
www.sensoraccess.co.uk
SWITCHINGOPERATONALMODES
FromNormaltoSecureMode/FromSecureModetoNormal
Thedefaultfactorysettingforthenormal/securecodeis3838
1)Enterthenormal/securecode
Modeindicatorwillflashred(normaltoSecure)orflashGreen(Secure
toNormal)
2)Depressthe#keytoconfirmtheModechange
ModeindicatorisredtoconfirminSecuremode/orgreentoconfirm
NormalMode
STANDARDMETHODFORENROLLING
1)Entertheprogrammingmode.
2)Depress7toenterMenu7.
TheDoorindicatorwillturnorange.
3)Enterthe3digituserslotnumberintothememory(from001to500)soastoenroll
aprimaryorsecondarycode.
Forexample,theuserslot003representsuserno.3.
4)Atthistimethreepossibilitiesexist:
a.Iftheselectedslothasnoprimarycode,theModeindicatorwillflashgreen,
indicatingthatthecontrollerisreadytoacceptaprimarycode.
b.Iftheselectedslotalreadyhasaprimarycode,butnosecondarycode,theMode
indicatorwillflashred,indicatingthatthecontrollerisreadytoacceptasecond‐
arycode.
c. Iftheselectedslotalreadyhasaprimaryandsecondarycode,alongbeepwillbeheardandthecontroller
willreturntoitsnormalmode.
5)Enterthecodetobeassignedastheprimaryorsecondarycodeforthisslotnumber.Ifthecodethatisen
teredisvalid,theModeindicatorwillceaseflashingandthecontrollerisreadyforthenext3digitslotnumber
(step3)ordepressthe#keytomovetothenextslotnumber(step4).Ifyoudonotwishtocontinueenrolling
codes,depressthe#keytwiceandthecontrollerwillreturntoitsnormalmode.
XPIN&XPROX
InstallGuide
www.sensoraccess.co.uk
DELETINGCODES
Whendeletingauserslot,boththeprimarycodeandthesecondarycodeareerased.
1)Entertheprogrammingmode.
2)Depress8toenterMenu8.
TheModeindicatorwillturnred.
3)Enterthe3digituserslotcodetobedeleted.
TheModeindicatorwillflashred,indicatingthecontrolleriswaitingforaprogrammingcode
toconfirmthedeletion.
Iftheuserslotisempty,alongbeepwillbeheardandthecontrollerwillreturntoits
normalmode.
4)Enteryourprogrammingcodetoconfirmthedeletion.Iftheprogrammingcodeisvalid,threebeepswillbe
heard
andthecontrollerwillreturntoitsnormalmode.
Iftheprogrammingcodeisinvalid,alongbeepwillbeheardandthecontrollerwillreturntoitsnormalmode.
SensorAccessTechnologyLtd
SensorHouse
1011LewesRoad
Brighton
EastSussex
BN24JZ
Tel:01273242355
Fax:01273235030
ForthefullUserManualpleasegoto:
public.sensoraccess.co.uk
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Sensor Access X-PIN Install Manual

Category
Security device components
Type
Install Manual
This manual is also suitable for

Sensor Access X-PIN is a single door controller that uses a PIN code for access control. It can be connected to a door contact and request to exit button to allow the system to send a signal to a sounder in case the door has been forced open or left open. The X-PIN has a maximum relay current of 2A, and its input voltage ranges from 12VDC to 24VDC or 12VAC to 24VAC. It has two 3-colored LED indicators and meets IP64 standards for outdoor usage.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI