Amperes AX700 User manual

Type
User manual
Thank you for choosing another quality product from Amperes Electronics.
AX700 is an automatic standby amplifier changeover unit which would provide auto surveillance setup for duty pa amplifiers.
It serves 6 duty amplifiers with one standby, with the ability to cascade to allow a single standby amplifier to serve more than
seven or more duty units. Reliability and durability is main concern and thereby we incorporate protection circuitries such as
priority changeover and standby amplifier overloading prevention.
Though it is rather simple in the installation works, a brief read throuh the manual is recommended and we are confident
that you are getting a product of excellence.
INSTRUCTION MANUAL
AX700
Auto Amplier Changeover Unit
VER 2 / 2015
AUTO STANDBY AMP CHANGEOVER
FAULT
STANDBY
5 64321
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
AMP.FAULT / LINE GND
AMP. NUMBER
AMP.OPERATIONAL
AX 700
amperes
Parts Identification
AUTO STANDBY AMP CHANGEOVER
FAULT
STANDBY
5 64321
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
AMP.FAULT / LINE GND
AMP. NUMBER
AMP.OPERATIONAL
AX 700
amperes
TO ZON E SEL ECTOR
OR SPEAK ERS
DUTY AM PL IFIE R INPU TS
LIN K TO A S4 00
A U T O A M P . C H A N G E O V E R
AM P .FA ULT DE TE C T TR IG G ER
D C 24 V
1
0.5 A
+
S/BY
COM
5 632 4
COM
HOT
HOT
COM
HOT
HOT
COM
HOT
COM
HOT
COM
COM
HOT
COM
HOT
AX7 00
IN
HOT
COM
HOT
COM
COM
COM
HOT
HOT
HOT
COM
S TA N DB Y
AM P INP U T
COM
PL EAS E O B S ER V E P OL A RIT Y
AS4 00
TO
1~ 6
CO M
OU T
IN
D UTY AM P
S/B Y A M P
OUT
DE TECT
LIN K
AMP .IN
AMP .OUT
S/B Y IN
A M P E R E S E LE C T R O NI C S
AM P . O UT - T O Z O N E S E LEC T O R / S PEA K ER S
AX 7 0 0 W IR IN G C O N N EC TIO N S
AM P . IN - FR . AM P O U TP U TS
M AX L O AD / C H - 4 0 0W / 1 0 0 V L IN E
Q u ali ty P ro d uc t Fr om
Front View:
Rear View:
2
5
1
3
4
6 7
1. AMPLIFIER OPERATIONAL LED
2. AMPLIFIER FAULT / LINE GND LED
3. STANDBY AMPLIFIER FAULT LED
4. AMP FAULT LED & BUZZER SWITCH
5. DC SUPPLY INPUT
6. AMP FAULT DETECT TRIGGER
The 6 green LED which lits indicates that the duty amplifiers are in good condition.
The red LED when lits indicate that the corresponding duty amplifier is faulty and its load has been taken over by the
standby unit. If more than 2 LED lit, the one with higher amplifier numbering would have priority to the standby unit.
At any one time, the standby amplifier is only allowed to serve a failed duty amp.
In the event that the standby amplifier is faulty, this LED would indicate its status in red colour.
Whenever a switchover takes place or duty amplifier/line fault is detected, an audible buzzer would sound with LED
indicator lit. The audio alarm can be switched off but the LED would remain until the fault is removed.
24V DC regulated supply is recommended as power source, eg . Amperes PS301S. Please observe polarity when
connecting.
Amperes AS4000 auto surveillance module is linked to this port (up to 6 units). If other detection module is to be
employed, please consult our technical department for details.
8 9
7. DUTY AMP. CONNECTION PORT
8. STANDBY AMP. PORT
9. LINK/CASCADE TERMINAL
Up to 6 duty amplifiers are to be connected to this terminals
Standby amplifier is terminated to this terminal. Correct polarity must be observed, otherwise would cause severe
damages to your amplifiers as well as the changeover unit.
If more than one AX700 is to be used (ie. 1 standby to serve more than 6 duty amplifiers), link all the AX700 using
this port.
PAGE 2 AX700 | AUTO AMPLIFIER CHANGEOVER UNIT
100V LINE
2 CORE CONTACT CABLE
LEGENDS
TO SPEAKER
ZONE SELECTOR
DUTY AMP 1
DUTY AMP 2
STANDBY AMP
AMPERES AX700
PUBLIC ADDRESS POWER AMPLIFIER ● QUANTUM POWER SERIES
PUBLIC ADDRESS POWER AMPLIFIER ● QUANTUM POWER SERIES
AUTO STANDBY AMP CHANGEOVER
FAULT
STANDBY
5 64321
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
AMP.FAULT / LINE GND
AMP. NUMBER
AMP.OPERATIONAL
AX 700
amperes
PAGE 3AX700 | AUTO AMPLIFIER CHANGEOVER UNIT
Application Schematic
PUBLIC ADDRESS POWER AMPLIFIER ● QUANTUM POWER SERIES
Note:
Some amplifiers may have fault detection features built in, such as QP2000 Series. Using AX700 for changeover may be
optional as the amplifier has built in changeover system, which simplifies cabling works.
Whereas if AX700 is required to perform the changeover, QP2000 has fault relay contact which can be linked to AX700 for
auto fault changeover setup.
APPLICATION USING QP2000 SERIES POWER AMPLIFIERS
PAGE 4 AX700 | AUTO AMPLIFIER CHANGEOVER UNIT
Application Schematic
APPLICATION USING AMPLIFIER FAULT DETECTION MODULE ( AS4000 )
Note:
The above illustration uses AS4000 alongside with power amplifiers that do not have built in fault detection feature such
as PA2000 series or any other similar brands.
AS4000 shall be used to perform fault monitoring task at the individual power pack and upon failure detection, a dry contact
shall be initiated and linked to AX700.
The changeover shall take place accordingly to ensure uninterrupted operation of the system.
70 / 100V LINE
AUDIO LINE SIGNAL
TRIGGER SIGNAL
LEGENDS
A+PT
TRIGGER
FROM SOUND MIXER
A + PT - AUDIO AND PILOT TONE
TO SPEAKER
ZONE SELECTOR
100V
AMP 1
AMP 2
AMP 6
STANDBY AMP
AS4000
AMPERES AX700
CONTN/O
FAILUREDETECTED
ampereselectronics
CONTN/C
CONTCOM
SIGOUT -
SIGOUT +
GND
SIGIN +
SIGIN -
Ensurecorrect power polarity
Userecommended power supply only
withPA amplifier of 70/100V line only
Thisappliance is intended to be used
amplifierline surveillance module
AS4000
WARNING:
PILOTSIGNAL TRANSMIT
DC24V+
DC24V-
AMP+
AMP-
AUTO STANDBY AMP CHANGEOVER
FAULT
STANDBY
5 64321
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
AMP.FAULT / LINE GND
AMP. NUMBER
AMP.OPERATIONAL
AX 700
amperes
CONTN/O
FAILUREDETECTED
ampereselectronics
CONTN/C
CONTCOM
SIGOUT -
SIGOUT +
GND
SIGIN +
SIGIN -
Ensurecorrect power polarity
Userecommended power supply only
withPA amplifier of 70/100V line only
Thisappliance is intended to be used
amplifierline surveillance module
AS4000
WARNING:
PILOTSIGNAL TRANSMIT
DC24V+
DC24V-
AMP+
AMP-
CONTN/O
FAILUREDETECTED
ampereselectronics
CONTN/C
CONTCOM
SIGOUT -
SIGOUT +
GND
SIGIN +
SIGIN -
Ensurecorrect power polarity
Userecommended power supply only
withPA amplifier of 70/100V line only
Thisappliance is intended to be used
amplifierline surveillance module
AS4000
WARNING:
PILOTSIGNAL TRANSMIT
DC24V+
DC24V-
AMP+
AMP-
CONTN/O
FAILUREDETECTED
ampereselectronics
CONTN/C
CONTCOM
SIGOUT -
SIGOUT +
GND
SIGIN +
SIGIN -
Ensurecorrect power polarity
Userecommended power supply only
withPA amplifier of 70/100V line only
Thisappliance is intended to be used
amplifierline surveillance module
AS4000
WARNING:
PILOTSIGNAL TRANSMIT
DC24V+
DC24V-
AMP+
AMP-
PUBLIC ADDRESS POWER AMPLIFIER
SIGNAL -40 dB
SIGNAL -10 dB
POWER
PROTECT
CLIP
PA 2480
amperes
PUBLIC ADDRESS POWER AMPLIFIER
SIGNAL -40 dB
SIGNAL -10 dB
POWER
PROTECT
CLIP
PA 2480
amperes
PUBLIC ADDRESS POWER AMPLIFIER
SIGNAL -40 dB
SIGNAL -10 dB
POWER
PROTECT
CLIP
PA 2480
amperes
PUBLIC ADDRESS POWER AMPLIFIER
SIGNAL -40 dB
SIGNAL -10 dB
POWER
PROTECT
CLIP
PA 2480
amperes
HOT
DUTY AMPLIFIER INPUTS
DC 24V
S/BY
+
0.5 A
4 6521
LINK TO AS4000
3
HOT
HOT
HOT
COM
COM
COM
HOT
HOT
COM
COM
HOT
COM
COM
AMP.FAULT DETECT TRIGGER
AMP INPUT
100V
COM
COM
HOT
100V
COM
COM
COM
100V
100V
100V
COM
COM
OUT
IN
STANDBY
AUTO AMP.CHANGEOVER
COM
N/O
RELAY CONTACT
OF AS4000
AS4000 FOR STANDBY AMP
COM
N/O
RELAY CONTACT
OF AS4000
AS4000 NO.6 FOR AMP 6
COM
N/O
RELAY CONTACT
OF AS4000
AS4000 NO.1 FOR AMP 1
TO NEXT AX700
(LOWER PRIORITY)
FROM PREV AX700
(HIGHER PRIORITY)
DC24V IN
(PS9400)
AMP IN
(NO 1)
AMP1 OUT
LINK TO AS4000
STANDBY
AMPLIFIER
LINK TO AS4000
Note :
Polarity must be observed in connections.
For detail connection of AS4000, please refer to its respective instruction manual for connection to other brand of
amplifier surveillance module, use the 'com' of AX700 as triggering signal.
Do not use direct 24V DC to trigger
PAGE 5AX700 | AUTO AMPLIFIER CHANGEOVER UNIT
Connecting The Unit
PAGE 6 AX700 | AUTO AMPLIFIER CHANGEOVER UNIT
Block Diagram
FAULT
DETECTION
PRIORITY &
CHANGE0VER DRIVER
CHANGEOVER RELAY
ARRAY
FRONT PANEL LEDs
& ALARM
TO AS4000
AS4000/AMP1
~
AS4000/AMP6
COM OUT
CASCADE LINK
IN
OUT
AMPLIFIER INPUTS
DUTY AMP1
~
DUTY AMP6
S/BY AMP
AMP OUT 1
AMP OUT 6
~
PAGE 7AX700 | AUTO AMPLIFIER CHANGEOVER UNIT
Operating voltage 24V DC via PS9400 PSU
Power consumption Standby : 82 mW, 3.4A
Operating : 1.3W, 50 mA
Zone load rating 500W / 100V line per ch.
Amplifier inputs 6 duty / 1 standby
Indications Red LED for take over
Green - normal / non c/over
Switching mode Dry contact activation by AS4000
Changeover alert Buzzer, LED
Changeover section Amplifier outputs only
Cable connection Plug in connectors
Cable size 2.5 mm sq
Dimensions (WxHxD) 482 x 44 x 180 mm
Weight 2.0 kg
Technical Specification
Summary Of Features
Cater for 6 duty and 1 standby amplifier
Expandable for 1 standby to serve more than 6 duty units
Overload protection by allowing only a single take over
Prioritized changeover - unit with higher number is preferred for changeover
Fault alert with LED indicator and switchable buzzer
Compatible with most auto detection cards
Warranty Conditions
Disclaimer
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
Published : APRIL 2015
ISO 9001: 2008
Design & Manufacture of Public Address Equipment and Systems
Certicate No. 16895 / A / 0001 / UK / En
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics
Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan
Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized
master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is not valid if repairs are
performed by unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as
removal and installation of the product from the main system are for the account of the purchaser. This warranty
shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the
product with power supply voltage other than shown on the product, or any other power supply source / adaptor
not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly
related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the
unit; moreover the warranty does not cover any damages which may be caused to people and things when using
the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on this
certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the
date of purchase or for a longer period in countries where this is stated by a national law. In this case, the
extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the
design changes or improvements are made.
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or
damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN
BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction
with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by
service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Amperes AX700 User manual

Type
User manual

Ask a question and I''ll find the answer in the document