1514
Zonesetupofaccessories
Every detector can be assigned to 4 dierent categories of zones: Home Zone, Delay Zone, Normal
Zone and 24-H Zone. To assign a detector to a zone, follow the instrucons on page 8 of this
manual (the zone will be assigned at the me of connecon of the accessory).
Normalzone
When the system is armed, if a sensor is triggered, the siren rings out. When the system is disarmed,
sensors do not trigger an alarm.
24hzone
Regardless the system is armed or disarmed, sensors assigned to the 24h zone can trigger an alarm.
Delayzone
If you want to set up the entry and exit delay funcons, corresponding sensors must be assigned to
the Delay zone. Once the delay me has been set up, the sensors will not trigger the alarm during
the delay set. Refer to the instrucons “Entry and Exit Delay” on page 10 of this manual.
Homezone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an
alarm.
Controlbyphonecall
Method 1
When an alarm has been triggered, the control panel dials the stored phone numbers. When you
pick up the phone, follow the voice instrucons to control t he p anel from distance (refer to the
instrucons in the table below).
Method 2
1. Dial the telephone number of your control panel (either the number of the SIM card in your
control panel or the number of the landline to which your panel is connected). Aer geng through,
the voice instrucons will guide you to enter your access code.
2. Enter your user code, followed by ”#”.
3. A voice gives you the opons you can select.
4. Select the operaons to control the panel (see instrucons in the table below).
Note
The call will end automacally if you do not send any command within 30 seconds.
Tableofcommandsforcontrolbyphonecall
Command Function Comment
Press “1“ Arms the system
Press “0“
- Disarms the system and turns the
siren o
- Stops monitoring without hanging up
- Stops the phone call funcon without
hanging up
Press “3“ Phone call with control panel
Press "*"
- Starts audio monitoring mode (not
limited in me)
- Stops the built-in siren and the wire-
less siren (if connected to the control
panel)
-
Press “6“ Turns all sirens o -
Press “9“
- Turns the built-in siren on (whether
the siren ringing sengs is ON or
OFF)
- Turns the wireless siren on (if con-
nected to the control panel)
-
Press “#“
- Turns all sirens o
- Exits control by phone call
- Stops call recycles
-
Note
In GSM mode, the audio monitoring is not limited in me.