Danfoss ECL Comfort 310, A333 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Danfoss ECL Comfort 310, A333 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
OperatingGuide
ECLComfort310,applicationA333
1.0TableofContents
1.0TableofContents...............................................1
1.1Importantsafetyandproductinformation.....................2
2.0Installation........................................................5
2.1Beforeyoustart.....................................................5
2.2Identifyingthesystemtype......................................10
2.3Mounting...........................................................15
2.4Placingthetemperaturesensors................................18
2.5Electricalconnections.............................................20
2.6InsertingtheECLApplicationKey..............................50
2.7Checklist............................................................56
2.8Navigation,ECLApplicationKeyA333.........................57
3.0Dailyuse.........................................................62
3.1Howtonavigate...................................................62
3.2Understandingthecontrollerdisplay..........................63
3.3Ageneraloverview:Whatdothesymbolsmean?...........65
3.4Monitoringtemperaturesandsystem
components........................................................66
3.5Influenceoverview................................................67
3.6Manualcontrol.....................................................68
3.7Schedule............................................................69
4.0Settingsoverview............................................70
5.0Settings...........................................................73
5.1IntroductiontoSettings..........................................73
5.2Flowtemperature..................................................74
5.3Returnlimit.........................................................76
5.4Flow/powerlimit.................................................79
5.5Optimization........................................................82
5.6Controlparameters1..............................................87
5.7Controlparameters,refillpump(s)..............................92
5.8Controlparameters,circulationpump(s)......................97
5.9Pumpcontrol.....................................................100
5.10Refillwater........................................................103
5.11Refilltank..........................................................110
5.12Application.......................................................113
5.13Watermeter......................................................117
5.14Flowmeter........................................................118
5.15S7,S8,S9,S10pressure.........................................121
5.16Alarm..............................................................124
6.0Commoncontrollersettings............................129
6.1IntroductiontoCommoncontrollersettings’..............129
6.2Time&Date.......................................................130
6.3Holiday............................................................131
6.4Inputoverview...................................................133
6.5Log.................................................................134
6.6Outputoverride..................................................135
6.7Keyfunctions.....................................................136
6.8System.............................................................138
7.0Miscellaneous................................................145
7.1ECA30/31setupprocedures.................................145
7.2Overridefunction................................................153
7.3Severalcontrollersinthesamesystem......................156
7.4Frequentlyaskedquestions....................................159
7.5Definitions........................................................162
7.6Type(ID6001),overview.......................................165
7.7ParameterIDoverview..........................................166
©Danfoss|2017.09VI.GU.T2.02|1
1.1Importantsafetyandproductinformation
1.1.1Importantsafetyandproductinformation
ThisInstallationGuideisassociatedwithECLApplicationKeyA333
(ordercodeno.087H3818).
ThefunctionsarerealizedinECLComfort310foradvanced
solutions,e.g.M-bus,ModbusandEthernet(Internet)
communication.
TheapplicationA333complieswithECLComfortcontrollers310as
ofsoftwareversion1.11(visibleatstart-upofthecontrollerandin
‘Commoncontrollersettingsin‘System’).
TheapplicationA333workswiththeInternalI/OmoduleECA32
(ordercodeno.087H3202).
AdditionaldocumentationforECLComfort310,modulesand
accessoriesisavailableonwww.ecl.doc.danfoss.com.
Applicationkeysmightbereleasedbeforealldisplaytextsare
translated.InthiscasethetextisinEnglish.
Automaticupdateofcontrollersoftware(firmware):
Thesoftwareofthecontrollerisupdatedautomaticallywhenthekey
isinserted(asofcontrollerversion1.11(ECL210/310)andversion
1.58(ECL296)).Thefollowinganimationwillbeshownwhenthe
softwareisbeingupdated:
Progressbar
Duringupdate:
DonotremovetheKEY
Ifthekeyisremovedbeforethehour-glassisshown,youhave
tostartafresh.
Donotdisconnectthepower
Ifthepowerisinterruptedwhenthehour-glassisshown,the
controllerwillnotwork.
2|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
SafetyNote
Toavoidinjuryofpersonsanddamagestothedevice,itisabsolutely
necessarytoreadandobservetheseinstructionscarefully.
Necessaryassembly,start-up,andmaintenanceworkmustbe
performedbyqualifiedandauthorizedpersonnelonly.
Locallegislationsmustberespected.Thiscomprisesalsocable
dimensionsandtypeofisolation(doubleisolatedat230V).
AfusefortheECLComfortinstallationismax.10Atypically.
TheambienttemperaturerangesforECLComfortinoperationare:
ECLComfort210/310:0-55°C
ECLComfort296:0-45°C.
Exceedingthetemperaturerangecanresultinmalfunctions.
Installationmustbeavoidedifthereisariskforcondensation(dew).
Thewarningsignisusedtoemphasizespecialconditionsthatshould
betakenintoconsideration.
Thissymbolindicatesthatthisparticularpieceofinformationshould
bereadwithspecialattention.
AsthisOperatingGuidecoversseveralsystemtypes,specialsystem
settingswillbemarkedwithasystemtype.Allsystemtypesareshown
inthechapter:'Identifyingyoursystemtype'.
°C(degreesCelsius)isameasuredtemperaturevaluewhereasK
(Kelvin)oftenisusedfortemperaturedifferences.
TheIDno.isuniquefortheselectedparameter.
ExampleFirstdigitSeconddigitLastthreedigits
1117411174
-
Circuit1Parameterno.
12174
1
2
174
-
Circuit2Parameterno.
IfanIDdescriptionismentionedmorethanonce,itmeansthatthere
arespecialsettingsforoneormoresystemtypes.Itwillbemarked
withthesystemtypeinquestion(e.g.12174-A266.9).
VI.GU.T2.02
©Danfoss|2017.09|3
OperatingGuideECLComfort310,applicationA333
ParametersindicatedwithanIDno.like"1x607"meanauniversal
parameter.
xstandsforcircuit/parametergroup.
DisposalNote
Thisproductshouldbedismantledanditscomponents
sorted,ifpossible,invariousgroupsbeforerecycling
ordisposal.
Alwaysfollowthelocaldisposalregulations.
4|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
2.0Installation
2.1Beforeyoustart
TheA333applicationkeycontains3subtypes:A333.1,A333.2
andA333.3whicharealmostidentical.
Differentandextrafunctionsaredescribedadditionally.
TheapplicationA333.1isveryflexible.
Thesearethebasicprinciples:
Typically,theflowtemperatureisadjustedaccordingtoyour
requirements.
TheflowtemperaturesensorS3isthemostimportantsensor.The
desiredflowtemperatureatS3iscalculatedintheECLcontroller,
basedontheoutdoortemperature(S1)andthedesiredroom
temperature.Thelowertheoutdoortemperature,thehigherthe
desiredflowtemperature.
Bymeansofaweekschedule(upto3'Comfort'periods/day),the
heatingcircuitcanbein'Comfort'or'Saving'mode(twodifferent
temperaturevaluesforthedesiredroomtemperature).
InSavingmodetheheatingcanbereducedorswitchedofftotally.
ThemotorizedcontrolvalveM1isopenedgraduallywhentheflow
temperatureS3islowerthanthedesiredflowtemperatureand
viceversa.
Thereturntemperature(S5)canbelimited,forexamplenottobe
toohigh.Ifso,thedesiredflowtemperatureatS3canbeadjusted
(typicallytoalowervalue),thusresultinginagradualclosingof
themotorizedcontrolvalve.Furthermore,thereturntemperature
limitationcanbedependentontheoutdoortemperature.
Typically,thelowertheoutdoortemperature,thehigherthe
acceptedreturntemperature.
Inboiler-basedheatingsupplythereturntemperatureshouldnot
betoolow(sameadjustmentprocedureasabove).
AconnectedfloworenergymeterbasedonM-bussignalcan
limitthefloworenergytoasetmaximumvalue.Furthermorethe
limitationcanbeinrelationtotheoutdoortemperature.Typically,
thelowertheoutdoortemperature,thehighertheacceptedflow/
power.
ThecirculationpumpsP1andP2areoperatedalternately.One
circulationpumpisusedasworkingpumpandtheothercirculation
pumpisusedassparepump.Thecirculationpumpinquestionis
ONatheatdemandoratfrostprotection.Thealternationtime
canbesetasanumberofdaysandasettimeontheshiftday.A
solutionwithasinglecirculationpumpcanalsobeselected.
BymeansofthepressuredifferencebetweenS9andS10the
ECLcontrollerverifiesthatthecirculationpumpinquestionis
operating.
Thepressuredifferenceonthesecondarysideisbasedonthestatic
pressuresatS9andS10.Thepressuresaremeasuredas0-10volt
signals(frompressuretransmitters)andconverted(scaled)inthe
ECLcontrollertoappropriatepressurevalues.
ApplicationA333.1:
Theshowndiagramisafundamentalandsimplifiedexampleanddoes
notcontainallcomponentsthatarenecessaryinasystem.
AllnamedcomponentsareconnectedtotheECLComfortcontroller.
Listofcomponents:
ECL310
ElectroniccontrollerECLComfort310
S1
Outdoortemperaturesensor
S2
(Optional)Primarysupplytemperaturesensor.For
monitoringpurpose
S3
Secondaryflowtemperaturesensor
S4
(Optional)Secondaryreturntemperaturesensor.For
monitoringpurpose
S5
(Optional)Primaryreturntemperaturesensor
S7
(Optional)Primarysupplypressuresensor.Formonitoring
purpose
S8
(Optional)Primaryreturnpressuresensor.Formonitoring
purpose
S9
Secondaryflowpressuresensor
S10
Secondaryreturnpressuresensor
M1
Motorizedcontrolvalve(3-pointcontrolled)
P1/P2
Circulationpumps
P3/P4
Refillwaterpumps
V1
Refillwatervalve
V2
Pressurereleasevalve
A1
Alarm
VI.GU.T2.02
©Danfoss|2017.09|5
OperatingGuideECLComfort310,applicationA333
Ifanacceptablepressuredifferenceisnotdetected,theECL
controlleractivatesthealarmandshiftstheoperatingcommandto
theoppositecirculationpump.
TheheatingcanbeswitchedOFFautomaticallywhentheoutdoor
temperatureishigherthanaselectablevalue.
TheFrostprotectionmodemaintainsaselectableflowtemperature,
forexample10°C.
Incaseofatoolowpressure,measuredbyS10,therefillwater
functionwillsupplementwithwaterfromawatersource.
ArefillpumpisswitchedONandtheON/OFFvalveV1opens.
TherefillpumpsP3andP4areoperatedalternately.Onepumpis
usedasworkingpumpandtheotherpumpisusedassparepump.
Thealternationtimecanbesetasanumberofdays.
Asolutionwithasinglerefillpumpcanalsobeselected.
Incaseofatoohighpressure,measuredbyS10,thereleasevalve
V2(ON/OFF)willopeninordertoreducethepressure.
6|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
TheapplicationA333.2isveryflexibleandworkslikeA333.1,
andwiththeseadditionalfeatures:
*
ThecirculationpumpsP1/P2can,asanalternativetoON-OFF
control,bespeedcontrolledbymeansofa0-10voltsignal.
ThedesiredpressuredifferencebetweenS9andS10issetfor
thespeedcontrolprocedure.
Aflow-meterF2(pulsesignal,analoguesignalS13orM-Bus)
measuresthecirculationofwaterintheheatingcircuit.
*
Thelevelintherefillwaterstoragetankismeasuredby
meansofthepressuresensorS12.Whenatoolowpressure
ismeasured,theON/OFFvalveV3opens.Anacceptable
pressurewillclosetheV3valve.
*
TherefillwaterpumpsP3/P4can,asanalternativetoON-OFF
control,bespeedcontrolledbymeansofa0-10voltsignal.
ThedesiredpressureatS10issetforthespeedcontrol
procedure.
Aflow-meterF1(pulsesignalorM-Bus)measurestheinjected
refillwater.
ApplicationA333.2:
Theshowndiagramisafundamentalandsimplifiedexampleanddoes
notcontainallcomponentsthatarenecessaryinasystem.
AllnamedcomponentsareconnectedtotheECLComfortcontroller.
Listofcomponents:
ECL310
ElectroniccontrollerECLComfort310
ECA32
Built-inextensionmodule
S1
Outdoortemperaturesensor
S2
(Optional)Primarysupplytemperaturesensor.For
monitoringpurpose
S3
Secondaryflowtemperaturesensor
S4
(Optional)Secondaryreturntemperaturesensor.For
monitoringpurpose
S5
(Optional)Primaryreturntemperaturesensor
S7
(Optional)Primarysupplypressuresensor.Formonitoring
purpose
S8
(Optional)Primaryreturnpressuresensor.Formonitoring
purpose
S9
Secondaryflowpressuresensor
S10
Secondaryreturnpressuresensor
F1
(Optional)Flowmeter(pulseorM-bussignal)
F2
(Optional)Flowmeter(pulse,0-10voltorM-bussignal)
M1
Motorizedcontrolvalve(3-pointcontrolled)
M2
Speedcontrol(0-10volt)ofP3/P4
M3
Speedcontrol(0-10volt)ofP1/P2
P1/P2
Circulationpumps
P3/P4
Refillwaterpumps
V1
Refillwatervalve
V2
Pressurereleasevalve
V3
Refillwatertankvalve
A1
Alarm
VI.GU.T2.02
©Danfoss|2017.09|7
OperatingGuideECLComfort310,applicationA333
TheapplicationA333.3isveryflexibleandworkslikeA333.2,
butwiththisfeature:
*
ThemotorizedcontrolvalveM1iscontrolledbymeansofa
0-10voltsignal.
ApplicationA333.2:
Theshowndiagramisafundamentalandsimplifiedexampleanddoes
notcontainallcomponentsthatarenecessaryinasystem.
AllnamedcomponentsareconnectedtotheECLComfortcontroller.
Listofcomponents:
ECL310
ElectroniccontrollerECLComfort310
ECA32
Built-inextensionmodule
S1
Outdoortemperaturesensor
S2
(Optional)Primarysupplytemperaturesensor.For
monitoringpurpose
S3
Secondaryflowtemperaturesensor
S4
(Optional)Secondaryreturntemperaturesensor.For
monitoringpurpose
S5
(Optional)Primaryreturntemperaturesensor
S7
(Optional)Primarysupplypressuresensor.Formonitoring
purpose
S8
(Optional)Primaryreturnpressuresensor.Formonitoring
purpose
S9
Secondaryflowpressuresensor
S10
Secondaryreturnpressuresensor
F1
(Optional)Flowmeter(pulseorM-bussignal)
F2
(Optional)Flowmeter(pulse,0-10voltorM-bussignal)
M1
Motorizedcontrolvalve(0-10voltcontrolled)
M2
Speedcontrol(0-10volt)ofP3/P4
M3
Speedcontrol(0-10volt)ofP1/P2
P1/P2
Circulationpumps
P3/P4
Refillwaterpumps
V1
Refillwatervalve
V2
Pressurereleasevalve
V3
Refillwatertankvalve
A1
Alarm
8|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
ApplicationA333ingeneral:
UptotwoRemoteControlUnits,theECA30canbeconnectedto
oneECLcontrollerinordertocontroltheECLcontrollerremotely.
Exerciseofcirculationpumpsandcontrolvalveinperiodswithout
heatingdemandcanbearranged.
AdditionalECLComfortcontrollerscanbeconnectedviatheECL
485businordertoutilizecommonoutdoortemperaturesignal,
timeanddatesignals.TheECLControllersintheECL485system
canworkinmaster-slavesystem.
Aconnectedfloworenergymeter(basedonM-bussignal)can
limitthefloworenergytoasetmaximumandinrelationtothe
outdoortemperature.
Unusedinputcan,bymeansofanoverrideswitch,beusedto
overridethescheduletoafixed'Comfort'or'Saving'mode.
ModbuscommunicationtoaSCADAsystemcanbeestablished.
TheM-busdatacanfurthermorebetransferredtotheModbus
communication.
AlarmA1(=relay6)canbeactivated:
iftheactualflowtemperaturediffersfromthedesiredflow
temperature.
ifatemperaturesensororitsconnectiondisconnects/short
circuits.(See:Commoncontrollersettings>System>Raw
inputoverview).
ifthecirculationpump(s)do(es)notgenerateacceptable
pressure.
iftherefillwaterpump(s)do(es)notgenerateacceptable
pressure.
ifmeasuredpressuresarenotinsideanacceptablepressure
range.
Thecontrollerispre-programmedwithfactorysettingsthatareshown
inthe‘ParameterIDoverview’appendix.
VI.GU.T2.02
©Danfoss|2017.09|9
OperatingGuideECLComfort310,applicationA333
2.2Identifyingthesystemtype
Sketchyourapplication
TheECLComfortcontrollerseriesisdesignedforawiderange
ofheating,domestichot-water(DHW)andcoolingsystemswith
differentconfigurationsandcapacities.Ifyoursystemdiffers
fromthediagramsshownhere,youmaywanttomakeasketch
ofthesystemabouttobeinstalled.Thismakesiteasiertouse
theOperatingGuide,whichwillguideyoustep-by-stepfrom
installationtofinaladjustmentsbeforetheend-usertakesover.
TheECLComfortcontrollerisauniversalcontrollerthatcanbe
usedforvarioussystems.Basedontheshownstandardsystems,
itispossibletoconfigureadditionalsystems.Inthischapteryou
findthemostfrequentlyusedsystems.Ifyoursystemisnotquite
asshownbelow,findthediagramwhichhasthebestresemblance
withyoursystemandmakeyourowncombinations.
SeetheInstallationGuide(deliveredwiththeapplicationkey)for
applicationtypes/sub-types.
Thecirculationpump(s)inheatingcircuit(s)canbeplacedintheflow
aswellasthereturn.Placethepumpaccordingtothemanufacturer’s
specification.
10|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
A333.1,ex.a
Heatingsystemwithcontrolofupto2circulationpumpsandupto2refillwaterpumps
A333.1,ex.b
Basicheatingsystem
VI.GU.T2.02
©Danfoss|2017.09|11
OperatingGuideECLComfort310,applicationA333
A333.1,ex.c
Heatingsystemwithcirculationpumpfeedback
A333.1,ex.d
Heatingsystemwithrefillwatersystem
12|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
A333.1,ex.e
Heatingsystemwithrefillwaterandexcesspressuresystem
A333.2,ex.a
HeatingsystemwithON/OFFandspeedcontrolofupto2circulationpumpsandupto2refillwaterpumps.Refillwaterstoragecontrol.
VI.GU.T2.02
©Danfoss|2017.09|13
OperatingGuideECLComfort310,applicationA333
A333.3,ex.a
HeatingsystemwithON/OFFandspeedcontrolofupto2circulationpumpsandupto2refillwaterpumps.Refillwaterstoragecontrol.
ControlvalveM1iscontrolledby0-10voltsignal.
14|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
2.3Mounting
2.3.1MountingtheECLComfortcontroller
SeetheInstallationGuidewhichisdeliveredtogetherwiththe
ECLComfortcontroller.
Foreasyaccess,youshouldmounttheECLComfortcontrollernear
thesystem.
ECLComfort210/296/310canbemounted
onawall
onaDINrail(35mm)
ECLComfort296canbemounted
inapanelcut-out
ECLComfort210canbemountedinanECLComfort310basepart
(forfutureupgrade).
Screws,PGcableglandsandrawlplugsarenotsupplied.
LockingtheECLComfort210/310controller
InordertofastentheECLComfortcontrollertoitsbasepart,secure
thecontrollerwiththelockingpin.
Topreventinjuriestopersonsorthecontroller,thecontrollerhasto
besecurelylockedintothebase.Forthispurpose,pressthelocking
pinintothebaseuntilaclickisheardandthecontrollernolonger
canberemovedfromthebase.
Ifthecontrollerisnotsecurelylockedintothebasepart,thereisarisk
thatthecontrollerduringoperationcanunlockfromthebaseandthe
basewithterminals(andalsothe230Va.c.connections)areexposed.
Topreventinjuriestopersons,alwaysmakesurethatthecontroller
issecurelylockedintoitsbase.Ifthisisnotthecase,thecontroller
shouldnotbeoperated!
VI.GU.T2.02
©Danfoss|2017.09|15
OperatingGuideECLComfort310,applicationA333
Theeasywaytolockthecontrollertoitsbaseorunlockitistousea
screwdriveraslever.
Mountingonawall
Mountthebasepartonawallwithasmoothsurface.Establishthe
electricalconnectionsandpositionthecontrollerinthebasepart.
Securethecontrollerwiththelockingpin.
MountingonaDINrail(35mm)
MountthebasepartonaDINrail.Establishtheelectrical
connectionsandpositionthecontrollerinthebasepart.Secure
thecontrollerwiththelockingpin.
DismountingtheECLComfortcontroller
Inordertoremovethecontrollerfromthebasepart,pulloutthe
lockingpinbymeansofascrewdriver.Thecontrollercannowbe
removedfromthebasepart.
Theeasywaytolockthecontrollertoitsbaseorunlockitistousea
screwdriveraslever.
16|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
BeforeremovingtheECLComfortcontrollerfromthebasepart,ensure
thatthesupplyvoltageisdisconnected.
2.3.2MountingtheRemoteControlUnitsECA30/31
Selectoneofthefollowingmethods:
Mountingonawall,ECA30/31
Mountinginapanel,ECA30
Screwsandrawlplugsarenotsupplied.
Mountingonawall
MountthebasepartoftheECA30/31onawallwithasmooth
surface.Establishtheelectricalconnections.PlacetheECA30/
31inthebasepart.
Mountinginapanel
MounttheECA30inapanelusingtheECA30framekit(ordercode
no.087H3236).Establishtheelectricalconnections.Securethe
framewiththeclamp.PlacetheECA30inthebasepart.TheECA
30canbeconnectedtoanexternalroomtemperaturesensor.
TheECA31mustnotbemountedinapanelifthehumidity
functionistobeused.
VI.GU.T2.02
©Danfoss|2017.09|17
OperatingGuideECLComfort310,applicationA333
2.4Placingthetemperaturesensors
2.4.1Placingthetemperaturesensors
Itisimportantthatthesensorsaremountedinthecorrectposition
inyoursystem.
Thetemperaturesensormentionedbelowaresensorsusedforthe
ECLComfort210/296/310serieswhichnotallwillbeneeded
foryourapplication!
Outdoortemperaturesensor(ESMT)
Theoutdoorsensorshouldbemountedonthatsideofthebuilding
whereitislesslikelytobeexposedtodirectsunshine.Itshouldnot
beplacedclosetodoors,windowsorairoutlets.
Flowtemperaturesensor(ESMU,ESM-11orESMC)
Placethesensormax.15cmfromthemixingpoint.Insystems
withheatexchanger,DanfossrecommendsthattheESMU-typeto
beinsertedintotheexchangerflowoutlet.
Makesurethatthesurfaceofthepipeiscleanandevenwhere
thesensorismounted.
Returntemperaturesensor(ESMU,ESM-11orESMC)
Thereturntemperaturesensorshouldalwaysbeplacedsothatit
measuresarepresentativereturntemperature.
Roomtemperaturesensor
(ESM-10,ECA30/31RemoteControlUnit)
Placetheroomsensorintheroomwherethetemperatureistobe
controlled.Donotplaceitonoutsidewallsorclosetoradiators,
windowsordoors.
Boilertemperaturesensor(ESMU,ESM-11orESMC)
Placethesensoraccordingtotheboilermanufacturers
specification.
Airducttemperaturesensor(ESMB-12orESMUtypes)
Placethesensorsothatitmeasuresarepresentativetemperature.
DHWtemperaturesensor(ESMUorESMB-12)
PlacetheDHWtemperaturesensoraccordingtothemanufacturers
specification.
Slabtemperaturesensor(ESMB-12)
Placethesensorinaprotectiontubeintheslab.
ESM-11:Donotmovethesensorafterithasbeenfastenedinorderto
avoiddamagetothesensorelement.
ESM-11,ESMCandESMB-12:Useheatconductingpasteforquick
measurementofthetemperature.
ESMUandESMB-12:Usingasensorpockettoprotectthesensorwill,
however,resultinaslowertemperaturemeasurement.
18|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
Pt1000temperaturesensor(IEC751B,1000Ω/0°C)
Relationshipbetweentemperatureandohmicvalue:
VI.GU.T2.02
©Danfoss|2017.09|19
OperatingGuideECLComfort310,applicationA333
2.5Electricalconnections
2.5.1Electricalconnections230Va.c.
Thecommongroundterminalisusedforconnectionofrelevant
components(pumps,motorizedcontrolvalves).
ECL210/310
ECL296
20|©Danfoss|2017.09
VI.GU.T2.02
OperatingGuideECLComfort310,applicationA333
/