V-ZUG 51047 Installation guide

Category
Freezers
Type
Installation guide

This manual is also suitable for

Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1019038-R05
1
General notes
Observe the local regulations. If installing into a combustible material, the guidelines and standards for fire protection must be
complied with.
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The appliance is available with left- and right-door opening.
The declared energy consumption was determined with a kitchen cabinet depth of 560 mm. The appliance is fully
functional with a kitchen cabinet depth of 550 mm but will have a slightly increased level of energy consumption.
Preparations
Niche width and ventilation
Check niche width. Width and height of appliance and niche must fit exactly.
Check ventilation opening in niche.
SMS appliances EURO appliances
5
47
b
0
-2
t
16–20
h
~555
550
N
E
605
≥200 cm²
≥40
≥200 cm²
h₁ah₂a
h₁+c-a/2h₂+c-a/2
a
≤594
t
b
16–20
560–568
N
E
h
a
≥550*
≥200 cm²
200 cm²
≥40
~602
a = Gap c = Niche overlap, * = Recommendation: 560 mm.
h [mm] t [mm] b [mm] h
1
[mm] h
2
[mm] N [mm] E [mm] Max. weight of
door leaf
h
1
/ h
2
[kg]
Door opening
angle
SMS
appliances
EURO
appliances
1522 (12/6) 545 548 889 (7/6) 635 (5/6) 1524
+2
1850 15 / 12 100 ° x x
1649 (13/6) 570 548 1016 (8/6) 635 (5/6) 1651
+2
2050 17.5 / 12 100 ° x -
1776 (14/6) 545 548 508 (4/6) 1270 (10/6) 1778
+2
2050 12 / 17.5 100 ° x x
1776 (14/6) 545 548 1143 (9/6) 635 (5/6) 1778
+2
2050 17.5 / 12 100 ° x x
1776 (14/6) 545 548 1270 (10/6) 508 (4/6) 1778
+2
2050 17.5 / 12 100 ° x x
Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1019038-R05
2
Allow a 200cm² opening top and bottom to ensure proper ventilation.
a) Use the hinge bolts supplied if the door leaf thickness exceeds 19mm.
ð This restricts the opening angle to 90°.
Installing
Place appliance in front of niche and insert mains plug.
If door opening is to be changed, push appliance halfway into niche and change door opening (see corresponding section).
Move bottle drawer (depending on model) sideways, according to corresponding section.
For EURO standard appliances:
clean the side panel and affix the filler strip. The filler strip must be requested at the same time as ordering the appliance.
1
1
4
5
3
2
EURO
*
*
*
*
Installation
Thickness of wood of door leaf: 16–20mm.
1.
Y
1
2
Y
Y
547SMS (Y1)
594–597 EURO (Y2)
-2
X
X
30
40
70
50
60
30
40
70
50
60
30
40
70
50
60
30
40
70
50
60
3
3
0
4
0
5
0
30
40
50
30
40
7
0
50
6
0
3
0
40
70
50
60
Y
X
2.
1
2
Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1019038-R05
3
3.
3.5 × 12 mm
5
3.5 × 12 mm
4
1
3
Z
4 × 12 mm
529
mm
2
4 × 12 mm
Z+4 mm
SMS 7 mm
EURO 25 mm
4.
5.
M4 × 8 mm (2×)
6.
3.5 × 12/16 mm (8×)
7.
3.5 × 12 mm (2×/4×)*
*
*
*
1
2
8.
!
(*) Depending on model
Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1019038-R05
4
9. 10.
3.5 × 12 mm (4×)
11.
1
2
12.
3.5 × 25 mm (2×)
1
2
Continue with these steps:
Following the operating instructions supplied, switch the appliance on and carry out the function check.
Switch the appliance off if it is not to be used immediately after installation.
Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1019038-R05
5
Changing door opening direction
Appliance door
The direction in which the door opens can be changed from right to left up as long as the appliance has not yet been fully in-
stalled in the niche.
The hinge cover is asymmetrical. If the direction in which the door opens is changed, a corresponding new hinge cover must
be used.
1.
1.
2.
2.
3. 4.
5. 6.
7. 8.
Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1019038-R05
6
9. 10.
11. 12.
2.
1.
13.
1.
2.
14.
1.
2.
15.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

V-ZUG 51047 Installation guide

Category
Freezers
Type
Installation guide
This manual is also suitable for