Installation instructions
Refrigerator/freezer
Integrated, double door
1019038-R05
04/01/2019
10181676
1
General notes
Observe the local regulations. If installing into a combustible material, the guidelines and standards for fire protection must be
complied with.
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
▸ Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The appliance is available with left- and right-door opening.
The declared energy consumption was determined with a kitchen cabinet depth of 560 mm. The appliance is fully
functional with a kitchen cabinet depth of 550 mm but will have a slightly increased level of energy consumption.
Preparations
Niche width and ventilation
▸ Check niche width. Width and height of appliance and niche must fit exactly.
▸ Check ventilation opening in niche.
SMS appliances EURO appliances
5
47
b
0
-2
t
16–20
h
~555
550
N
E
605
≥200 cm²
≥40
≥200 cm²
h₁ – ah₂ – a
h₁+c-a/2h₂+c-a/2
a
≤594
t
b
16–20
560–568
N
E
h
a
≥550*
≥200 cm²
≥200 cm²
≥40
~602
a = Gap c = Niche overlap, * = Recommendation: 560 mm.
h [mm] t [mm] b [mm] h
1
[mm] h
2
[mm] N [mm] E [mm] Max. weight of
door leaf
h
1
/ h
2
[kg]
Door opening
angle
SMS
appliances
EURO
appliances
1522 (12/6) 545 548 889 (7/6) 635 (5/6) 1524
+2
1850 15 / 12 100 ° x x
1649 (13/6) 570 548 1016 (8/6) 635 (5/6) 1651
+2
2050 17.5 / 12 100 ° x -
1776 (14/6) 545 548 508 (4/6) 1270 (10/6) 1778
+2
2050 12 / 17.5 100 ° x x
1776 (14/6) 545 548 1143 (9/6) 635 (5/6) 1778
+2
2050 17.5 / 12 100 ° x x
1776 (14/6) 545 548 1270 (10/6) 508 (4/6) 1778
+2
2050 17.5 / 12 100 ° x x