ote:N source drawing reference wiring diagram 286979.
ote:N For kits with a green OFF light, an additional top added
NC auxiliary is needed to be supplied by the customer.
NC2
NC1
STOP/OFF
2/13 3/14
R1
M
A2
A1
M
X2X1
RUN
R
1
2
96
95
OL
X2X1
OFF
G
1
2
T1
6261
M
9897
OL
1
2
1
2
1
2
BLK/RED
BLK/RED
RED
RED
RED
RED
BLK/WHT
BLK/WHT
RED
BLK
RED
(BLU IF DC)
RED
(BLU/WHT IF DC)
DASHED COMPONENTS ARE OPTIONAL
USE AS REQUIRED FOR SELECTED COVER CONTROL OPTIONS
REFERENCE NOTES BELOW FOR CONTROL POWER WIRING OPTIONS
1/L1 OR SEPARATE CONTROL
3/L2 OR SEPARATE CONTROL
RED
RED
4
NO4
NO3
START/ON
2/13 3/14
R1
M
BLK
4
YEL
WIRING FOR START/ON ONLY
START/ON OR STOP/OFF PUSHBUTTON
OPTIONS SHOWN: RUN LIGHT, AND OFF LIGHT
OPTION FOR RUN LIGHT (RED TYPICAL)
REQUIRED FOR 480V OPTION
OPTION FOR START/ON OR STOP/OFF PB
1
2
3
4
OPTION FOR OFF LIGHT (GREEN TYPICAL) (INCLUDES 1NO-1NC AUX)
WIRING FOR DC STARTERS ONLY
A1
M HOLD
A2
M PICKUP
X2X1
RUN
R
R1
M LATE OPENING
96
95
OL
9897
OL
BLU
RED
BLK/RED BLK/RED
BLU BLU
CONTROL POWER WIRING NOTES
CAUTION
READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER!
THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE CONTROL
MODES OR CONTROL VOLTAGES. CHECK NAMEPLATE FOR COIL VOLTAGE.
: CONNECT SEPARATE CONTROL LINES TO THE
NO. 61 TERMINAL ON THE TOP ADDER AUX. AND TO THE NO. 96 TERMINAL ON THE
OVERLOAD RELAY.
: REMOVE WIRE "C2" IF SUPPLIED. IF WIRE
"C1" IS TERMINATED ON L1, DISCONNECT FROM L1. CONNECT SEPARATE CONTROL
LINES TO THE "C1" WIRE OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM
AND TO THE NO. 96 TERMINAL ON THE OVERLOAD RELAY.
: ADD WIRE "C2" IF NOT SUPPLIED. ADD
CONNECTOR BETWEEN L1 TERMINAL AND THE NO. 61 TERMINAL ON THE TOP ADDER
AUX. OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM.
: ADD WIRE "C1" AND "C2" IF NOT SUPPLIED.
SEPARATE CONTROL POWER
COMMON CONTROL POWER
FOR COIL VOLTAGES 120V AND LESS
FOR COIL VOLTAGES GREATER THAN 120V
FOR COIL VOLTAGES 120V AND LESS
FOR COIL VOLTAGES GREATER THAN 120V
1NO-1NC TOP ADDER AUX INCLUDED FOR COIL VOLTAGES 120V AND
LESS FOR SEPARATE CONTROL. FOR HIGHER COIL VOLTAGES, 1/L1 IS
CONNECTED TO PILOT DEVICE TERMINAL FOR COMMON CONTROL
5
T1
6261
M
T1
5453
M
5
3
R
F
OLF
FWD/UP
0
REV/DWN
REDBLK
REV/OFF/FWD OR DWN/OFF/UP 3-POSITION SELECTOR SWITCH
OPTIONS SHOWN: REV/DWN LIGHT AND FWD/UP LIGHT
RED
(BLU IF DC)
RED
(BLU IF DC)
BLU
RED
RED
BLU
BLU
BLU
BLU
BLU/WHT
BLK/RED BLK/RED
BLK/RED BLK/RED
BLK/RED BLK/RED
BLK/RED
A2
R PICKUP
A2
F PICKUP
X2X1
REV/DWN
R
X2X1
FWD/UP
R
A1
R HOLD
9897
OL
9695
OL
A1
F HOLD
2
1
2
1
RED
RED
2
1
RED
2
1
X2X1
REV/DWN
R
X2X1
FWD/UP
R
NO4 NO3
XOO
NO4 NO3
OOX
3/14/542/13/53
L1
A2
A1
R
L1
_/21/617/22/62
F
5/14/544/13/53
R1
R
9897
OL
9695
A2
A1
R1
_/21/616/22/62
RED
(BLU IF DC)
RED
(BLU IF DC)
1/L1 OR SEPARATE CONTROL
3/L2 OR SEPARATE CONTROL
RED
RED
DASHED COMPONENTS ARE OPTIONAL
USE AS REQUIRED FOR SELECTED COVER CONTROL OPTIONS
1
1
2
RED
2
WIRING FOR DC STARTERS ONLY
OPTION FOR RUN LIGHT (RED TYPICAL)
REQUIRED FOR 480V OPTION
TWO 2NO TOP ADDER AUX INCLUDED FOR ALL COIL VOLTAGES.
WHEN COIL VOLTAGES 120V AND LESS, CONTROL WIRING ROUTED
TO NO. 63 TERMINAL FOR SEPARATE CONTROL.
1
2
3
T2
6463
R
6463
T1
F
T2
5453
R
5453
T1
F
3
L1
F LATE OPENING
BLK/RED
R1
R LATE OPENING
SEPARATE CONTROL WIRES
REFERENCE NOTES BELOW FOR CONTROL POWER WIRING OPTIONS
CONTROL POWER WIRING NOTES
CAUTION
SEPARATE CONTROL POWER
COMMON CONTROL POWER
READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER!
THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE CONTROL
MODES OR CONTROL VOLTAGES. CHECK NAMEPLATE FOR COIL VOLTAGE.
: CONNECT SEPARATE CONTROL LINES TO THE
NO. 63 OR NO. 61 TERMINAL PER DIAGRAM ON THE TOP ADDER AUX. AND TO THE NO.
96 TERMINAL ON THE OVERLOAD RELAY.
: REMOVE WIRE "C2" IF SUPPLIED. IF WIRE
"C1" IS TERMINATED ON L1, DISCONNECT FROM L1. CONNECT SEPARATE CONTROL
LINES TO THE "C1" WIRE OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM
AND TO THE NO. 96 TERMINAL ON THE OVERLOAD RELAY.
: ADD WIRE "C2" IF NOT SUPPLIED. ADD
CONNECTOR BETWEEN L1 TERMINAL AND THE NO. 61 OR NO. 63 TERMINAL PER
DIAGRAM ON THE TOP ADDER AUX. OR APPROPRIATE PILOT DEVICE TERMINAL PER
DIAGRAM.
: ADD WIRE "C1" AND "C2" IF NOT SUPPLIED.
FOR COIL VOLTAGES 120V AND LESS
FOR COIL VOLTAGES GREATER THAN 120V
FOR COIL VOLTAGES 120V AND LESS
FOR COIL VOLTAGES GREATER THAN 120V
6
Instructions and Operation P52899
Effective May 2015
Box 1 Non-Combination Enclosed Control
and C600M Cover Control Kit Wiring
EATON www.eaton.com