Danfoss S42 P is a reliable and efficient pump designed for industrial applications. It features a lip type shaft seal that can be replaced without major disassembly of the unit. The pump's internal retaining ring and O-ring ensure a secure fit and prevent leakage. With its robust construction and easy maintenance, Danfoss S42 P is a great choice for demanding applications.

Danfoss S42 P is a reliable and efficient pump designed for industrial applications. It features a lip type shaft seal that can be replaced without major disassembly of the unit. The pump's internal retaining ring and O-ring ensure a secure fit and prevent leakage. With its robust construction and easy maintenance, Danfoss S42 P is a great choice for demanding applications.

A lip type shaft seal is used in Series 42 pumps. This seal is retained within a seal carrier and, combined with the
lip seal, make up the shaft seal/carrier assembly. The shaft seal/carrier assembly can be replaced without major
disassembly of the unit. However, the replacement of the shaft seal/carrier assembly does require that the pump
be removed from the machine.
Removal of the Shaft Seal/Carrier Assembly
1) Position the pump such that the pump’s input shaft is facing
up.
2) Remove the internal retaining ring from the housing, using
a standard screwdriver, or similar tool. The retaining ring
can be removed by “spiraling” the ring out of the housing,
once the leading edge is pried free.
3) Remove the shaft seal/carrier assembly from the housing
by prying the assembly out with the aid of a standard
screwdriver, or similar tool.
4) Remove the O-ring from the shaft seal/carrier assembly.
Note that the O-ring may still be within the pump, in which
case it will be located on top of the shaft’s front bearing.
Installation of the Shaft Seal/Carrier Assembly
1) Lubricate the new O-ring with a petroleum based lubricant
and place into the pump cavity on top of the shaft’s front
bearing. Make sure that the O-ring makes contact with
the entire bearing surface so as to avoid damage occurring
to the O-ring upon the installation of the shaft seal/carrier
assembly.
2) Wrap the spline or key end of the shaft with thin plastic in
order to prevent damage to the lip seal during installation.
3) Lubricate the inside diameter of the shaft seal with a
petroleum-based lubricant.
4) Install the shaft seal/carrier assembly by sliding the shaft
seal/carrier assembly over the shaft, taking care not to
damage the lip seal. Press the shaft seal/carrier assembly
into the housing so that the internal retaining ring groove
is visible above the shaft seal/carrier assembly.
5) Install the new internal retaining ring into the housing by
first inserting the trailing end of the ring and “spiraling the
ring into its machined groove within the housing.
6) Remove the plastic used to protect the lip seal during
installation.
Retaining Ring
O-Ring
Pump Cavity
Shaft Seal/Carrier Assembly
Screwdriver
Pry Point
© Danfoss, 2013 BLN-10198 Rev AA • September 2013 1
Service Kit Instructions
Series 42
Shaft seal replacement procedure
  • Page 1 1

Danfoss S42 P Installation guide

Type
Installation guide

Danfoss S42 P is a reliable and efficient pump designed for industrial applications. It features a lip type shaft seal that can be replaced without major disassembly of the unit. The pump's internal retaining ring and O-ring ensure a secure fit and prevent leakage. With its robust construction and easy maintenance, Danfoss S42 P is a great choice for demanding applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI