Danfoss DCM-P & PA Installation guide

Type
Installation guide
VMBQA102
Installation
DCM-P,
DCM-PA
VMBQA102
3
VMBQA102
Contents
1 Area of use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 For the installer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Pipe installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3 Dimensions for connections
Dimensions for connection Passive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Dimentions for connection Passive/Active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.1 Internal connections
Internal Connection Passive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Internal Connection Passive/Active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
4 Electrical wire diagram
Electrical Wiring Cooling Module Passive 230 V
External Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electrical Wiring Cooling Module Passive 230 V
Circuit diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Connection Box Cooling Module Passive 230 V
Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Wiring Diagram Cooling Module Passive 230 V
Part List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Electrical Wiring Cooling Module Passive/Active 230 V
External Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Wiring Cooling Module Passive/Active 230 V
Circuit Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Connection Box, Cooling Module Passive/Active 230 V
Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Wiring Diagram Cooling Module Passive/Active 230 V
Part List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cooling Module, Heating mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cooling Module, Passive cool mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cooling Module, Active cool mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
VMBQA102
5
VMBQA102
1 Area of use
For cooling requirements greater than can be obtained only
through passive cooling (free cooling).
For cooling requirements at max. 20 kW.
The cooling module makes it possible to retain passive or passive/
active cooling from the rock –groundwater collectors. The distribu-
tion system for this can be the radiator system (fan convectors) or
under floor heating systems. Cooling starts when the outside tem-
perature exceeds the set value for heat stop.
2.1 For the installer
2.1.1 Pipe installation
The cooling module must be mounted hanging vertically on a wall.
The central distance for mounting holes is 530 mm.
Pipe installation is carried out according to the wiring diagrams
found on page 8-13.
Installation must be carried out under the supervision of an autho-
rised electrician.
Function during cooling operation
Stage 1. Passive cooling
In order for the heat pump to start passive cooling, the following
conditions must be fulfilled:
1. The outside temperature is higher than the setting for heat
stop.
2. Room temperature exceeds the desired temperature by the
same amount of degrees that the room factor is set to.
3. The above requirements must be met within 5 minutes.
The heat pumps internal brine pump starts and circulates the coo-
lant via the cooling module to the bore hole. In the cooling module,
the set temperature is shunted out to the cooling system
530 mm
Stage 2. passive/active cooling (this function are only available
on the passive/active module)
In order for the heat pump to start passive cooling, the following
conditions must be fulfilled:
1. All conditions for passive cooling must be fulfilled.
2. Room temperature exceeds the desired temperature by twice
the room factor.
3. The above requirements must be met for 1 minute.
4. If the in coolant temperature exceeds the desired temperature
to the cooling system during passive cooling, active cooling is
force connected after 120 seconds
The heat pumps compressor starts and the shift valves for active
cooling operation are reset. In the first instance, the excess heat is
used, which is produced in the heat pump’s condenser for hot water
heating. When the hot water is heated, the excess heat is shifted
down to the bore hole. This provides more favourable operation for
the heat pump at the same time as a high cooling effect and good
efficiency is achieved.
6
VMBQA102
3 Dimensions for connections
Dimensions for connections Passive
Dimensions for connections Passive/Active
722
60
60
A
B
H
J
475
599
72260
60
A
B
C
D
E
F
G
H
J
475
599
7
VMBQA102
3.1 Internal connection
Internal connection Passive
Internal connection Passive/Active
Exp.kort
901 515
J
H
D
A
Heat pump
Groundsource
Cooling module
Radiators or fan convectors
Exp.kort
901 515
J
H
A
D
E
F
G
B
C
Cooling module
Heatpump
Radiators or fan convectors
Groundsource
8
VMBQA102
4 Electrical wire diagram
Electrical Wiring Cooling Module Passive 230 V
External Wiring
Electrical Wiring Cooling Module Passive 230 V
Circuit diagram
9
VMBQA102
Connection Box, Cooling Module Passive 230 V
Layout
Wiring Diagram Colling Module Passive 230 V
Part List
10
VMBQA102
Electrical Wiring Cooling Module Passive/Active 230 V
External Wiring
Electrical Wiring Cooling Module Passive/Active 230 V
Circuit Diagram
11
VMBQA102
Connection Box Cooling Module Passive/Active 230 V
Layout
Wiring Diagram Cooling Module Passive/Active 230 V
Part List
12
VMBQA102
Cooling Module, Heating mode
A
A
A D B C
J H E F
Exp.
KV
VV
Supply line
Framledning
Cooling circuit
Kylkrets
Accessory
Tillbehör
Brine In
Köldbärare in
Brine Out
Köldbärare ut
Cooling module
Passive/Active
Kylmodul
Passiv/Aktiv
Return line
Returledning
G
B
B
AB
AB
13
VMBQA102
Cooling Module, Passive cool mode
Accessory
Tillbehör
A
A
A D B C
J H E F
Exp.
KV
VV
Supply line
Framledning
Cooling circuit
Kylkrets
Brine In
Köldbärare in
Brine Out
Köldbärare ut
Cooling module
Passive/Active
Kylmodul
Passiv/Aktiv
Return line
Returledning
G
B
B
AB
AB
14
VMBQA102
Cooling Module, Active cool mode
A
A
A D B C
J H E F
Exp.
KV
VV
Supply line
Framledning
Cooling circuit
Kylkrets
Brine In
Köldbärare in
Brine Out
Köldbärare ut
Cooling module
Passive/Active
Kylmodul
Passiv/Aktiv
Return line
Returledning
G
B
B
AB
AB
Accessory
Tillbehör
VMBQA102
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Danfoss DCM-P & PA Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI