Columbia Lighting Row Mount Operating instructions

Type
Operating instructions
Row Mount Ordering Instructions
MPS8-30LW-EDDU-ELL14-NXS-MST-EOR
8’ Row Wiring Harness 8’ Row Wiring Harness8’ Row Wiring Harness8’ Row Wiring Harness
8’ Row Wiring Harness
MPS8-30LW-EDDU-SAT-INT MPS8-30LW-EDDU-SAT-INT MPS8-30LW-EDDU-SAT-INT MPS8-30LW-EDDU-NXS-MST-EOR
MPS, 16' Row, (2) 8' Fixtures
MPS8-30LW-EDDU-ELL14-SAT-EOR MPS8-30LW-EDDU-NXS-MST-EOR
8’ Row Wiring Harness 8’ Row Wiring Harness
LEGEND
EOR – End of Row
MST
– Master fixture (contains control module and sensor)
SAT – Controlled by master fixture
– Female wiring harness quick connector
– Male wiring harness quick connector
BUILD NOTES
- NX descriptor only needed in catalog string of master fixture.
- Emergency descriptor only needed in catalog string of
emergency fixture.
ROW DESCRIPTION
- NXS, 1 sensor on master fixture
- Battery on fixture without sensor
MPS, 40' Row, (5) 8' Fixtures
LEGEND
EOR – End of Row fixture
INT – Intermediate fixture
MST – Master fixture (contains control module and sensor)
SAT – Controlled by master fixture
– Female wiring harness quick connector
– Male wiring harness quick connector
BUILD NOTES
- NX descriptor only needed in catalog string of master fixtures.
- Emergency descriptor only needed in catalog string of
emergency fixture.
- Master/satellite control determined by wiring harness connections.
ROW DESCRIPTION
- NXS, 2 sensors on master fixtures
- Battery on an end of row fixture
- Master with battery will control one satellite,
other master will control two satellites
MPS
MULTIPURPOSE LINEAR
currentlighting.com/columbialighting
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 1 of 3
Rev 10/21/22
COL_row_mount_ins
Row Mount Ordering Instructions
RLW
REVALUME™ LINEAR WRAP
MPS4-2750TLW-EDDU-ELL14-NXS-MST-EORMPS8-2750TLW-EDDU-SAT-INT MPS4-2750TLW-EDDU-ELL14-NXS-MST-EOR
MPS8-2750TLW-EDDU-SAT-INT MPS8-2750TLW-EDDU-SAT-INT MPS8-2750TLW-EDDU-SAT-INT
4’ Row Wiring Harness 8’ Row Wiring Harness 8’ Row Wiring Harness 8’ Row Wiring Harness
8’ Row Wiring Harness 4’ Row Wiring Harness
MPS, 40' Row, (4) 8' Fixtures and (2) 4' Fixtures
LEGEND
EOR – End of Row fixture
INT – Intermediate fixture
MST – Master fixture (contains control module and sensor)
SAT – Controlled by master fixture
– Female wiring harness quick connector
– Male wiring harness quick connector
BUILD NOTES
- NX descriptor only needed in catalog string of master fixtures.
- Emergency descriptor only needed in catalog string of
emergency fixture.
- Master/satellite control determined by wiring harness connections.
- Color tuning must be specified for master and satellite fixtures.
ROW DESCRIPTION
- NXS, 2 sensors on 4’ master fixtures
- Battery on each end of row fixture
- Each master to control half of row
- Color tuning
RLW, 24' Row, (3) 8' Fixtures
LEGEND
EOR – End of Row fixture
INT – Intermediate fixture
MST – Master fixture (contains control module and sensor)
SAT – Controlled by master fixture
– Female wiring harness quick connector
– Male wiring harness quick connector
BUILD NOTES
- NX descriptor only needed in catalog string of master fixture.
- Emergency descriptor only needed in catalog string of
emergency fixture.
ROW DESCRIPTION
- NXOS, 1 sensor on master fixture
- Battery in middle of row
RLW8-30LW-EDDU-NXOS-MST-EOR RLW8-30LW-EDDU-SAT-EOR
RLW8-30LW-EDDU-ELL14-SAT-INT
8’ Row Wiring Harness 8’ Row Wiring Harness 8’ Row Wiring Harness
MPS
MULTIPURPOSE LINEAR
currentlighting.com/columbialighting
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 3
Rev 10/21/22
COL_row_mount_ins
Row Mount Ordering Instructions
RLB
REVERIE™ DECORATIVE LOW BAY
RLB8-30LV-ED1U-NXSPWH-U2-MST-EOR
8’ Row Wiring Harness 8’ Row Wiring Harness 8’ Row Wiring Harness 8’ Row Wiring Harness
RLB8-30LV-ED1U-U2-SAT-INT RLB8-30LV-ED1U-U2-SAT-INT RLB8-30LV-ED1U-NXSPWH-U2-MST-EOR
RLB, 32' Row, (4) 8' Fixtures
ROW DESCRIPTION
- NXSPWH, 2 sensors on master fixtures
- Uplight on all fixture
LEGEND
EOR – End of Row fixture
INT – Intermediate fixture
MST – Master fixture (contains control module and sensor)
SAT – Controlled by master fixture
– Female wiring harness quick connector
– Male wiring harness quick connector
BUILD NOTES
- NX descriptor only needed in catalog string of master fixtures.
- Uplight descriptor needed on all fixtures with uplight.
currentlighting.com/columbialighting
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.