Dell OpenManage Server Administrator Version 7.2 User manual

  • Hello! I am an AI chatbot trained to assist you with the Dell OpenManage Server Administrator Version 7.2 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Server Administrator Storage
Management
User’s Guide
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
____________________
Information in this publication is subject to change without notice.
© 2012 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, PowerEdge™, PowerVault™, and
OpenManage™ are trademarks of Dell Inc. Microsoft
®
, Windows
®
, and Windows Server
®
are either
trademarks or registered trademarks of Microsoft Corporation in the United States and/or other
countries. Red Hat Enterprise Linux
®
and Enterprise Linux
®
are registered trademarks of Red Hat,
Inc. in the United States and/or other countries. Novell
®
is a registered trademark and SUSE ™ is a
trademark of Novell Inc. VMware
®
is a registered trademarks or trademarks of VMWare, Inc. in the
United States or other countries.
Server Administrator includes software developed by the Apache Software Foundation
(www.apache.org). Server Administrator utilizes the OverLIB JavaScript library. This library can be
obtained from www.bosrup.com.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
2012 - 12
Contents 3
Contents
1Overview . . . . . . . . . . . . . . . . . . . . . . . . . 21
What’s New in this Release? . . . . . . . . . . . . . . 21
Before Installing Storage Management
. . . . . . . . . 22
Version Requirements for Controller Firmware
and Drivers
. . . . . . . . . . . . . . . . . . . . . 22
Supported Controllers
. . . . . . . . . . . . . . . . . . 23
Supported Enclosures . . . . . . . . . . . . . . . . . . 24
Support for Disk and Volume Management
. . . . . . . 24
2 Getting Started . . . . . . . . . . . . . . . . . . . . 25
Launching Storage Management . . . . . . . . . . . . 26
Microsoft Windows
. . . . . . . . . . . . . . . . . 26
Linux and any Remote System
. . . . . . . . . . . 26
User Privileges
. . . . . . . . . . . . . . . . . . . . . . 26
Using the Graphical User Interface
. . . . . . . . . . . 27
Storage Object
. . . . . . . . . . . . . . . . . . . 27
Health Subtab
. . . . . . . . . . . . . . . . . . . . 27
Information/Configuration Subtab
. . . . . . . . . 27
Drop-down Menus and Wizards
for Running Tasks . . . . . . . . . . . . . . . . . . 27
Using the Storage Management Command Line
Interface
. . . . . . . . . . . . . . . . . . . . . . . . . 28
Displaying the Online Help
. . . . . . . . . . . . . . . 28
4 Contents
Common Storage Tasks . . . . . . . . . . . . . . . . . 28
3 Understanding RAID Concepts . . . . . . . 31
What Is RAID? . . . . . . . . . . . . . . . . . . . . . . 31
Hardware and Software RAID
. . . . . . . . . . . 31
RAID Concepts
. . . . . . . . . . . . . . . . . . . 32
RAID Levels . . . . . . . . . . . . . . . . . . . . . 33
Organizing Data Storage for Availability
and Performance
. . . . . . . . . . . . . . . . . . . . . 33
Choosing RAID Levels and Concatenation . . . . . . . 34
Concatenation
. . . . . . . . . . . . . . . . . . . 35
RAID Level 0 (Striping) . . . . . . . . . . . . . . . 36
RAID Level 1 (Mirroring)
. . . . . . . . . . . . . . 38
RAID Level 5 (Striping with distributed parity)
. . . 39
RAID Level 6 (Striping with additional
distributed parity) . . . . . . . . . . . . . . . . . . 40
RAID Level 50 (Striping over RAID 5 sets) . . . . . 42
RAID Level 60 (Striping over RAID 6 sets)
. . . . . 44
RAID Level 10 (Striping over mirror sets)
. . . . . . 46
RAID Level 1-Concatenated
(Concatenated mirror) . . . . . . . . . . . . . . . 48
Comparing RAID Level and Concatenation
Performance
. . . . . . . . . . . . . . . . . . . . . . . 49
No-RAID
. . . . . . . . . . . . . . . . . . . . . . . . . 51
4 Quick Access to Storage Status
and Tasks
. . . . . . . . . . . . . . . . . . . . . . . . 53
Storage Dashboard and Storage Health. . . . . . . . . 53
Contents 5
Storage Health . . . . . . . . . . . . . . . . . . . . . . 53
Hot Spare Protection Policy
. . . . . . . . . . . . . . . 54
Select Report
. . . . . . . . . . . . . . . . . . . . . . . 54
Storage Component Severity . . . . . . . . . . . . . . 54
Storage Properties and Current Activity
. . . . . . . . 55
Alerts or Events
. . . . . . . . . . . . . . . . . . . . . 56
Monitoring Disk Reliability on RAID Controllers . . . . 56
Using Alarms to Detect Failures
. . . . . . . . . . . . . 56
Using Enclosure Temperature Probes
. . . . . . . . . . 57
Rescan to Update Storage Configuration Changes . . . 57
Time Delay in Displaying Configuration Changes
. . . 58
5 PCI Express Solid-State Device
Support . . . . . . . . . . . . . . . . . . . . . . . . . . 59
What is PCIe SSD . . . . . . . . . . . . . . . . . . . . 59
PCIe SSD Features
. . . . . . . . . . . . . . . . . . . . 59
PCIe Sub System Properties
. . . . . . . . . . . . . . . 60
PCIe Extender Cards . . . . . . . . . . . . . . . . . . . 61
Physical Device Properties
. . . . . . . . . . . . . . . 61
Physical Device Tasks
. . . . . . . . . . . . . . . . . . 62
Blink and Unblink
. . . . . . . . . . . . . . . . . . 63
Full Initialization
. . . . . . . . . . . . . . . . . . . 63
Prepare to Remove
. . . . . . . . . . . . . . . . . 63
6 Contents
Export Log . . . . . . . . . . . . . . . . . . . . . . 64
PCIe SSD Sub System Health
. . . . . . . . . . . . . . 64
Backplanes
. . . . . . . . . . . . . . . . . . . . . 64
Backplane Firmware Version
. . . . . . . . . . . . 64
6 Storage Information and
Global Tasks . . . . . . . . . . . . . . . . . . . . . . 65
Storage Properties . . . . . . . . . . . . . . . . . . . . 65
Global Tasks
. . . . . . . . . . . . . . . . . . . . . . . 65
Global Rescan
. . . . . . . . . . . . . . . . . . . . 66
Enable/Disable Smart Thermal Shutdown
. . . . . 66
Storage Controllers
. . . . . . . . . . . . . . . . . . . 67
Storage Components
. . . . . . . . . . . . . . . . 70
7 Controllers . . . . . . . . . . . . . . . . . . . . . . . 71
What is a Controller?. . . . . . . . . . . . . . . . . . . 71
RAID Controller Technology: SCSI, SATA, ATA,
and SAS
. . . . . . . . . . . . . . . . . . . . . . . . . 72
RAID Controller Features
. . . . . . . . . . . . . . . . 72
Controller-supported RAID Levels . . . . . . . . . . . . 74
Controller-supported Stripe Sizes
. . . . . . . . . . . . 74
RAID Controller Read, Write, Cache, and
Disk Cache Policy
. . . . . . . . . . . . . . . . . . . . 74
Read Policy
. . . . . . . . . . . . . . . . . . . . . 74
Write Policy
. . . . . . . . . . . . . . . . . . . . . 76
Cache Policy
. . . . . . . . . . . . . . . . . . . . 77
Contents 7
Disk Cache Policy. . . . . . . . . . . . . . . . . . 78
Background Initialization on PERC Controllers
. . . . . 78
Non-RAID Controller Description
. . . . . . . . . . . . 79
Firmware/Driver Versions . . . . . . . . . . . . . . . . 79
Firmware/Driver Properties
. . . . . . . . . . . . 80
Controller Health
. . . . . . . . . . . . . . . . . . . . . 82
Controller Severity
. . . . . . . . . . . . . . . . . 82
Controller Information
. . . . . . . . . . . . . . . 83
Controller Components . . . . . . . . . . . . . . . 83
Controller Properties and Tasks. . . . . . . . . . . . . 84
Controller Properties
. . . . . . . . . . . . . . . . 84
Controller Tasks. . . . . . . . . . . . . . . . . . . 89
Available Reports
. . . . . . . . . . . . . . . . . . 90
Set Rebuild Rate
. . . . . . . . . . . . . . . . . . . . . 94
Reset Configuration
. . . . . . . . . . . . . . . . . . . 95
Export Log . . . . . . . . . . . . . . . . . . . . . . . . 96
Foreign Configuration Operations
. . . . . . . . . . . . 97
Foreign Configuration Properties
. . . . . . . . . . 98
Importing Foreign Configurations
. . . . . . . . . . . . 101
Importing/Recovering Foreign Configurations . . . . . 102
Clear Foreign Configuration
. . . . . . . . . . . . . . . 103
Physical Disks in Foreign Virtual Disks
. . . . . . . . . 104
Set Background Initialization Rate
. . . . . . . . . . . 109
Set Check Consistency Rate
. . . . . . . . . . . . . . . 110
8 Contents
Set Reconstruct Rate. . . . . . . . . . . . . . . . . . 111
Redundant Path Configuration
. . . . . . . . . . . . . 112
Clearing the Redundant Path View
. . . . . . . . 115
Related Topics
. . . . . . . . . . . . . . . . . . 115
Set Patrol Read Mode
. . . . . . . . . . . . . . . . . 115
Start and Stop Patrol Read
. . . . . . . . . . . . . . . 117
Change Controller Properties . . . . . . . . . . . . . 118
Manage Physical Disk Power
. . . . . . . . . . . . . 119
Manage Preserved Cache
. . . . . . . . . . . . . . . 123
Manage Preserved Cache
. . . . . . . . . . . . 123
Manage Encryption Key . . . . . . . . . . . . . . . . 124
Encryption Key
. . . . . . . . . . . . . . . . . . 125
Creating an Encryption Key and
Enabling LKM . . . . . . . . . . . . . . . . . . . 125
Manage CacheCade
. . . . . . . . . . . . . . . . . . 127
Creating a CacheCade
. . . . . . . . . . . . . . 127
Resizing the CacheCade
. . . . . . . . . . . . . 128
Renaming the CacheCade . . . . . . . . . . . . 128
Blinking and Unblinking the CacheCade
. . . . . 128
Deleting the CacheCade
. . . . . . . . . . . . . 129
CacheCade Properties . . . . . . . . . . . . . . 129
Convert to Non-RAID Disks . . . . . . . . . . . . . . 130
Convert to RAID Capable Disks
. . . . . . . . . . . . 130
Patrol Read Report
. . . . . . . . . . . . . . . . . . . 131
Check Consistency Report
. . . . . . . . . . . . . . . 131
Slot Occupancy Report
. . . . . . . . . . . . . . . . . 131
Contents 9
Physical Disk Firmware Version Report. . . . . . . . . 132
8 Enclosures and Backplanes . . . . . . . . . 135
Backplanes . . . . . . . . . . . . . . . . . . . . . . . 135
Enclosures
. . . . . . . . . . . . . . . . . . . . . . . . 135
Enclosure Physical Disks
. . . . . . . . . . . . . . 136
Enclosure Fans
. . . . . . . . . . . . . . . . . . . 136
Enclosure Power Supplies
. . . . . . . . . . . . . 136
Enclosure Temperature Probes . . . . . . . . . . 136
Enclosure Management Modules (EMMs)
. . . . . 137
SMART Thermal Shutdown
. . . . . . . . . . . . . . . 138
Changing the Mode on 220S and 221S Enclosures . . . 138
Enclosure Management
. . . . . . . . . . . . . . . . . 139
Enclosure and Backplane Health
. . . . . . . . . . . . 140
Enclosure and Backplane Status
. . . . . . . . . . 140
Enclosure and Backplane Information
. . . . . . . 140
Enclosure and Backplane Components . . . . . . 141
Enclosure and Backplane Properties and Tasks . . . . 141
Enclosure and Backplane Properties
. . . . . . . 141
Enclosure Tasks . . . . . . . . . . . . . . . . . . 144
Available Reports
. . . . . . . . . . . . . . . . . . 145
Set Asset Data
. . . . . . . . . . . . . . . . . . . . . . 148
Set Temperature Probe Values
. . . . . . . . . . . . . 149
View Slot Occupancy Report
. . . . . . . . . . . . . . 150
EMM Properties
. . . . . . . . . . . . . . . . . . . . . 151
10 Contents
Fan Properties . . . . . . . . . . . . . . . . . . . . . 153
Power Supply Properties
. . . . . . . . . . . . . . . 155
Temperature Probe Properties and Tasks
. . . . . . . 157
Temperature Probe Properties and Tasks
. . . . 157
Set Temperature Probe Properties and Tasks
. . 159
9 Connectors. . . . . . . . . . . . . . . . . . . . . . . 161
Channel Redundancy and Thermal Shutdown . . . . 161
Creating a Channel-redundant Virtual Disk . . . . . . 161
Connector Health
. . . . . . . . . . . . . . . . . . . . 163
Connector Status
. . . . . . . . . . . . . . . . . 163
Connector Information
. . . . . . . . . . . . . . 164
Connector Components. . . . . . . . . . . . . . 164
Connector Properties and Tasks. . . . . . . . . . . . 164
Connector Properties
. . . . . . . . . . . . . . . 164
Connector Tasks: Rescan Connector
. . . . . . . 166
Connector Components
. . . . . . . . . . . . . . 166
Logical Connector Properties and Tasks
. . . . . . . 166
Logical Connector Properties
. . . . . . . . . . . 166
Path Health
. . . . . . . . . . . . . . . . . . . . 167
Clearing the Redundant Path View . . . . . . . . 167
Related Tasks
. . . . . . . . . . . . . . . . . . . 168
Logical Connector Components
. . . . . . . . . 168
10 Tape Drives . . . . . . . . . . . . . . . . . . . . . . 169
Tape Drive Properties . . . . . . . . . . . . . . . . . 169
Contents 11
11 RAID Controller Batteries . . . . . . . . . . . 171
Battery Properties and Tasks . . . . . . . . . . . . . . 171
Battery Properties
. . . . . . . . . . . . . . . . . 171
Battery Tasks
. . . . . . . . . . . . . . . . . . . . 173
12 Physical Disks or Physical Devices. . . . 177
Guidelines to Replace a Physical Disk or
Physical Device . . . . . . . . . . . . . . . . . . . . . 177
Add a New Disk to Your System
. . . . . . . . . . . . . 178
How to Avoid Removing the Wrong Disk
. . . . . . . . 179
Replacing a Physical Disk Receiving
SMART Alerts
. . . . . . . . . . . . . . . . . . . . . . 179
Other Disk Procedures. . . . . . . . . . . . . . . . . . 180
Physical Disk or Physical Device Properties
and Tasks
. . . . . . . . . . . . . . . . . . . . . . . . . 180
Physical Disk or Physical Device Properties
. . . . 181
Physical Disk or Physical Device Tasks
. . . . . . 187
Blink and Unblink (Physical Disk)
. . . . . . . . . . . . 188
Remove Dead Segments
. . . . . . . . . . . . . . . . . 189
Prepare to Remove
. . . . . . . . . . . . . . . . . . . . 189
Rebuild
. . . . . . . . . . . . . . . . . . . . . . . . . . 190
Cancel Rebuild
. . . . . . . . . . . . . . . . . . . . . . 190
Assign and Unassign Global Hot Spare
. . . . . . . . . 190
Online and Offline
. . . . . . . . . . . . . . . . . . . . 192
12 Contents
Clear Physical Disk and Cancel Clear. . . . . . . . . 192
Revertible Hot Spare
. . . . . . . . . . . . . . . . . . 193
Instant Encrypt Erase
. . . . . . . . . . . . . . . . . . 194
Full Initialization . . . . . . . . . . . . . . . . . . . . 195
Convert to RAID Capable Disk
. . . . . . . . . . . . . 196
Convert to Non-RAID Disk
. . . . . . . . . . . . . . . 196
13 Virtual Disks. . . . . . . . . . . . . . . . . . . . . . 197
Considerations Before Creating Virtual Disks . . . . 197
Virtual Disk Considerations for Controllers
. . . . 198
Virtual Disk Considerations for PERC S100,
S110, and S300 Controllers . . . . . . . . . . . . 200
Virtual Disk Considerations on Linux
. . . . . . . 201
Number of Physical Disks per Virtual Disk . . . . 201
Maximum Number of Virtual Disks
per Controller . . . . . . . . . . . . . . . . . . . 202
Calculation for Maximum Virtual Disk Size
and the Create Virtual Disk Express Wizard
. . . 202
Channel Redundant Virtual Disks . . . . . . . . . 202
Creating Virtual Disks
. . . . . . . . . . . . . . . . . 203
Reconfiguring/Migrating Virtual Disks
. . . . . . . . 204
Starting and Target RAID Levels for Virtual Disk
Reconfiguration and Capacity Expansion
. . . . . . . 204
Maintain Integrity of Redundant Virtual Disks
. . . . 207
Rebuilding Redundant Information
. . . . . . . . . . 208
Virtual Disk Bad Block Management
. . . . . . . . . 208
Contents 13
What is a Virtual Disk Bad Block? . . . . . . . . . 208
Recommendations . . . . . . . . . . . . . . . . . 210
Virtual Disk Properties and Tasks . . . . . . . . . . . . 210
Virtual Disk Properties
. . . . . . . . . . . . . . . 210
Virtual Disk Tasks . . . . . . . . . . . . . . . . . . 214
Create Virtual Disk Express Wizard. . . . . . . . . . . 219
Create Virtual Disk Express Wizard (Step 2)
. . . . . . 221
Create Virtual Disk Advanced Wizard
. . . . . . . . . . 222
Create Virtual Disk Advanced Wizard (Step 2) . . . . . 226
Create Virtual Disk Advanced Wizard (Step 3)
. . . . . 228
Span Edit
. . . . . . . . . . . . . . . . . . . . . . . . . 230
Virtual Disk Task: Reconfigure (Step 1 of 3). . . . . . . 230
Virtual Disk Task: Reconfigure (Step 2 of 3)
. . . . . . . 232
Virtual Disk Task: Reconfigure (Step 3 of 3)
. . . . . . . 234
Slow and Fast Initialize
. . . . . . . . . . . . . . . . . 234
Considerations for Fast Initialize
. . . . . . . . . . 234
Considerations for Slow Initialize
. . . . . . . . . 235
Formatting or Initializing a Disk
. . . . . . . . . . . 235
Virtual Disk Task: Delete
. . . . . . . . . . . . . . . . 236
Virtual Disk Task: Rename
. . . . . . . . . . . . . . . . 237
Virtual Disk Task: Change Policy
. . . . . . . . . . . . 238
Split Mirror
. . . . . . . . . . . . . . . . . . . . . . . . 239
Unmirror
. . . . . . . . . . . . . . . . . . . . . . . . . 239
14 Contents
Assign and Unassign Dedicated Hot Spare . . . . . . 240
Virtual Disk Task: Replace Member Disk
(Step 1 of 2)
. . . . . . . . . . . . . . . . . . . . . . . 241
Virtual Disk Task: Replace Member Disk
(Step 2 of 2)
. . . . . . . . . . . . . . . . . . . . . . . 243
14 Moving Physical and Virtual Disks
from One System to Another . . . . . . . . . 245
Required Conditions . . . . . . . . . . . . . . . . . . 245
Migrating SAS Virtual Disks to Another System
. . . 246
15 Protecting Your Virtual Disk with
a Hot Spare . . . . . . . . . . . . . . . . . . . . . . 247
Understanding Hot Spares . . . . . . . . . . . . . . . 247
Setting Hot Spare Protection Policy
. . . . . . . . . . 247
Dedicated Hot Spare Protection Policy
. . . . . 248
Resetting the Hot Spare Protection Policy
. . . . 248
Global Hot Spare Protection Policy. . . . . . . . 249
Considerations for Hot Spare Protection
Policy
. . . . . . . . . . . . . . . . . . . . . . . 249
Considerations for Enclosure Affinity. . . . . . . 249
Considerations for Hot Spares on PERC 5/E,
PERC 5/i, PERC 6/E, PERC 6/I, and CERC 6/I
Controllers
. . . . . . . . . . . . . . . . . . . . . . . 250
Dedicated Hot Spare Considerations
. . . . . . . 251
Considerations for Hot Spares on S100,
and S300 Controllers
. . . . . . . . . . . . . . . . . . 252
Contents 15
Size Requirements for Global Hot Spares on
S100, and S300 Controllers
. . . . . . . . . . . . . 252
Global Hot Spare Considerations on a SAS 6/iR . . . . 252
16 CacheCade Using Solid State
Drives . . . . . . . . . . . . . . . . . . . . . . . . . . 255
17 Troubleshooting . . . . . . . . . . . . . . . . . . . 257
Common Troubleshooting Procedures . . . . . . . . . 257
Cables Attached Correctly
. . . . . . . . . . . . . 257
System Requirements. . . . . . . . . . . . . . . . 258
Drivers and Firmware
. . . . . . . . . . . . . . . . 258
Isolate Hardware Problems
. . . . . . . . . . . . 258
Rescan to Update Information on
SCSI Controllers . . . . . . . . . . . . . . . . . . 258
Replacing a Failed Disk
. . . . . . . . . . . . . . . 259
Replacing a Failed Physical Disk that is Part
of a Non-Redundant Virtual Disk . . . . . . . . . . 260
Recovering from Removing the Wrong
Physical Disk . . . . . . . . . . . . . . . . . . . . 261
Resolving Microsoft Windows Upgrade
Problems
. . . . . . . . . . . . . . . . . . . . . . 261
Virtual Disk Troubleshooting . . . . . . . . . . . . . . 261
A Rebuild Does Not Work
. . . . . . . . . . . . . 262
A Rebuild Completes with Errors . . . . . . . . . . 263
Cannot Create a Virtual Disk
. . . . . . . . . . . . 263
A Virtual Disk of Minimum Size is Not Visible
to Windows Disk Management. . . . . . . . . . . 264
Virtual Disk Errors on Linux
. . . . . . . . . . . . . 264
Problems Associated With Using the Same
Physical Disks for Both Redundant and
Non-Redundant Virtual Disks. . . . . . . . . . . . 265
16 Contents
Specific Problem Situations and Solutions . . . . . . 265
Physical Disk is Offline or Displays an
Error Status
. . . . . . . . . . . . . . . . . . . . 266
Receive a “Bad Block” Alert with
“Replacement,” “Sense,” or “Medium”
Error . . . . . . . . . . . . . . . . . . . . . . . . 266
Read and Write Operations Experience
Problems
. . . . . . . . . . . . . . . . . . . . . 267
A Task Menu Option is Not Displayed . . . . . . 268
A Corrupt Disk or Drive Message Suggests
Running autocheck During a Reboot
. . . . . . . 268
Erroneous Status and Error Messages after
a Windows Hibernation. . . . . . . . . . . . . . 268
Storage Management May Delay Before
Updating Temperature Probe Status . . . . . . . 268
Storage Management May Delay Displaying
Storage Devices After Reboot
. . . . . . . . . . 269
You are Unable to Log into a Remote System. . . 269
Cannot Connect to Remote System Running
Windows Server 2003
. . . . . . . . . . . . . . . 269
Reconfiguring a Virtual Disk Displays Error
in Mozilla Browser . . . . . . . . . . . . . . . . 269
Physical Disks Display Under Connector
Not Enclosure Tree Object . . . . . . . . . . . . 270
PCIe SSD Troubleshooting
. . . . . . . . . . . . . . . 270
Peripheral Component Interconnect Express
(PCIe) Solid-State Drive (SSD) is not seen in
the operating system
. . . . . . . . . . . . . . . 270
PCIe SSD is not seen in disk management in
the operating system . . . . . . . . . . . . . . . 270
18 Frequently Asked Questions . . . . . . . . . 273
Why is a Rebuild not Working? . . . . . . . . . . . . 273
Contents 17
How Can I Safely Remove or Replace a
Physical Disk?
. . . . . . . . . . . . . . . . . . . . . . 273
How do I Recover from Removing the Wrong
Physical Disk?
. . . . . . . . . . . . . . . . . . . . . . 274
How do I Identify the Firmware Version that
is installed?
. . . . . . . . . . . . . . . . . . . . . . . 274
Which Controllers do I Have? . . . . . . . . . . . . . . 274
How do I Turn off an Alarm?
. . . . . . . . . . . . . . . 275
Which RAID level is Best for me?
. . . . . . . . . . . . 275
A Supported Features . . . . . . . . . . . . . . . . 277
Supported Features on the PERC 5/ PERC 6/,
and CERC 6/I Controllers
. . . . . . . . . . . . . . . . . 277
Controller Tasks
. . . . . . . . . . . . . . . . . . . 277
Battery Tasks
. . . . . . . . . . . . . . . . . . . . 280
Connector Tasks . . . . . . . . . . . . . . . . . . 280
Physical Disk Tasks
. . . . . . . . . . . . . . . . . 281
Virtual Disk Tasks
. . . . . . . . . . . . . . . . . . 282
Virtual Disk Specifications . . . . . . . . . . . . . 283
Supported RAID Levels
. . . . . . . . . . . . . . . 286
Read, Write, Cache and Disk Cache Policy
. . . . 286
Enclosure Support . . . . . . . . . . . . . . . . . 287
Supported Features on the PERC Hardware
Controllers
. . . . . . . . . . . . . . . . . . . . . . . . 287
Controller Tasks
. . . . . . . . . . . . . . . . . . . 288
Battery Tasks
. . . . . . . . . . . . . . . . . . . . 292
Connector Tasks
. . . . . . . . . . . . . . . . . . 293
Physical Disk Tasks
. . . . . . . . . . . . . . . . . 293
Virtual Disk Tasks
. . . . . . . . . . . . . . . . . . 295
18 Contents
Virtual Disk Specifications . . . . . . . . . . . . 297
Supported RAID Levels . . . . . . . . . . . . . . 299
Read, Write, Cache and Disk Cache Policy
. . . . 300
Enclosure Support
. . . . . . . . . . . . . . . . 301
Supported Features on the SAS 5/iR, SAS 6/iR,
and PERC H200 Controllers
. . . . . . . . . . . . . . 301
Controller Tasks
. . . . . . . . . . . . . . . . . . 302
Battery Tasks . . . . . . . . . . . . . . . . . . . 303
Connector Tasks
. . . . . . . . . . . . . . . . . 303
Physical Disk Tasks
. . . . . . . . . . . . . . . . 304
Virtual Disk Tasks . . . . . . . . . . . . . . . . . 305
Supported RAID Levels
. . . . . . . . . . . . . . 306
Virtual Disk Specifications
. . . . . . . . . . . . 306
Read, Write, Cache and Disk Cache Policy. . . . 308
Enclosure Support
. . . . . . . . . . . . . . . . 309
Supported Features on the PERC S100, PERC S110,
and S300 Controllers
. . . . . . . . . . . . . . . . . . 310
Controller Tasks
. . . . . . . . . . . . . . . . . . 310
Physical Disk Tasks . . . . . . . . . . . . . . . . 310
Virtual Disk Tasks
. . . . . . . . . . . . . . . . . 311
Virtual Disk Specifications
. . . . . . . . . . . . 311
Supported RAID Levels . . . . . . . . . . . . . . 313
Read, Write, Cache and Disk Cache Policy
. . . . 313
Enclosure Support
. . . . . . . . . . . . . . . . 314
Supported Features on the Non-RAID Controllers
. . 314
Controller Tasks
. . . . . . . . . . . . . . . . . . 315
Battery Tasks
. . . . . . . . . . . . . . . . . . . 316
Connector Tasks
. . . . . . . . . . . . . . . . . 316
Physical Disk Tasks
. . . . . . . . . . . . . . . . 316
Virtual Disk Tasks
. . . . . . . . . . . . . . . . . 317
Enclosure Support
. . . . . . . . . . . . . . . . 318
Contents 19
Enclosure and Backplane Features . . . . . . . . . . . 318
Enclosure and Backplane Tasks
. . . . . . . . . . 319
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Maximum Supported Configuration
. . . . . . . . . . . 319
19 Determining the Health Status for
Storage Components . . . . . . . . . . . . . . . 321
Health Status Rollup: Battery is Charging
or Dead . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Health Status Rollup: Physical Disks in a
Virtual Disk are Failed or Removed
. . . . . . . . . . . 322
Health Status Rollup: Physical Disks in a
Virtual Disk are Unsupported, Partially or
Permanently Degraded
. . . . . . . . . . . . . . . . . 322
Health Status Rollup: All Physical Disks in a
Virtual Disk are in Foreign State
. . . . . . . . . . . . 323
Health Status Rollup: Some Physical Disks in a
Virtual Disk are in Foreign State
. . . . . . . . . . . . 324
Health Status Rollup: Virtual Disk is Degraded;
Physical Disks are Failed or Rebuilding
. . . . . . . . 324
Health Status Rollup: Virtual Disk is Failed. . . . . . . 325
Health Status Rollup: Unsupported Firmware
Version
. . . . . . . . . . . . . . . . . . . . . . . . . . 326
Health Status Rollup: Enclosure Power Supply
Failed or Power Connection Removed
. . . . . . . . . 326
Health Status Rollup: One Enclosure Fan is
Failed
. . . . . . . . . . . . . . . . . . . . . . . . . . . 327
20 Contents
Health Status Rollup: One Enclosure EMM is
Failed
. . . . . . . . . . . . . . . . . . . . . . . . . . 327
Health Status Rollup: One Enclosure Temperature
Probe is Failed
. . . . . . . . . . . . . . . . . . . . . 328
Health Status Rollup: Lost Both Power Connections
to the Enclosure
. . . . . . . . . . . . . . . . . . . . 328
Health Status Rollup: One or More Physical Disks
are Failed
. . . . . . . . . . . . . . . . . . . . . . . . 329
Health Status Rollup: Physical Disk is Rebuilding . . 330
/