RH Systems PT-12, PT12 Owner's manual

  • Hello, I am a chat assistant. I have read the RH Systems PT12 user manual. I can provide you with information about connecting temperature probes, configuring channels, understanding the various display modes, and data logging. I am ready to answer your questions about the features and operation of the PT12.
  • What type of probes does the PT12 support?
    What are the available current modes?
    How can I connect the PT12 to a PC?
    What is the data logging interval?
PT12
RHSystems,LLC
1225WHoustonAve.,
GilbertAZ,85233
Manual
Introduction
PT12Manual 7/20/2021
Page2of48
TABLEOFCONTENTS 
Introduction...........................................................................................................................................................5
QuickStart/InitialSetup.......................................................................................................................................6
2.1
ConnectingaTemperatureProbe.................................................................................................................6
StartingUpthePT12..............................................................................................................................................7
3.1
ObtainingaReading.......................................................................................................................................7
3.2
PlottingTemperature....................................................................................................................................9
Operation.............................................................................................................................................................10
4.1
ConnectingTemperatureProbes.................................................................................................................10
4.1.1
BasicProbes.........................................................................................................................................11
4.1.2
SmartProbes.......................................................................................................................................12
4.1.3
UserSuppliedProbes..........................................................................................................................12
4.2
ChannelMeasurementRate........................................................................................................................13
4.3
NavigatingtheUserInterface......................................................................................................................13
4.3.1
TemperatureGraphDisplayMode......................................................................................................14
ScrollingtheGraph..........................................................................................................................15
ZoomingtheGraph..........................................................................................................................16
AxisControl......................................................................................................................................16
GraphStatistics................................................................................................................................17
4.3.2
ResistanceGraph.................................................................................................................................18
4.3.3
AllTemperatureDisplayMode............................................................................................................18
4.3.4
AllResistanceDisplayMode................................................................................................................19
4.3.5
Numeric4xDisplayMode....................................................................................................................19
4.3.6
Numeric2xDisplaymode....................................................................................................................20
4.3.7
ComboDisplayMode...........................................................................................................................21
4.3.8
ProbeStatusDisplayMode..................................................................................................................22
4.3.9
ChangingDisplayedUnitsofMeasurement........................................................................................23
4.3.10
ChangingNumberFormat...................................................................................................................23
4.4
ConfiguringtheProbes................................................................................................................................24
4.4.1
Averaging.............................................................................................................................................25
4.4.2
CurrentMode......................................................................................................................................26
4.4.3
CoefficientMode.................................................................................................................................27
CallendarVanDusen(CVD).............................................................................................................27
ITS90................................................................................................................................................28
4.4.4
ProbeConfigurationManagement......................................................................................................32
4.5
FileManager................................................................................................................................................34
4.5.1
CopyingLogFilestoUSBDrive............................................................................................................34
4.5.2
DeletingLogFiles.................................................................................................................................34
4.5.3
SetPreferredLoggingLocation............................................................................................................35
4.6
SystemInfo..................................................................................................................................................36
SerialCommunications........................................................................................................................................37
5.1
SerialConnections.......................................................................................................................................37
5.1.1
ElectricalWiringtotheRS232Ports...................................................................................................37
RS232PinOut..................................................................................................................................37
SerialConfiguration.........................................................................................................................38
5.1.2
USBtoSerialPort.................................................................................................................................38
5.2
Protocol.......................................................................................................................................................39
5.2.1
CommunicationSequenceandTerminationCharacters.....................................................................39
5.2.2
CaseSensitivity....................................................................................................................................39
5.2.3
NumericValues....................................................................................................................................39
5.3
CommandList..............................................................................................................................................40
5.3.1
SystemLevelCommands.....................................................................................................................40
5.3.2
ChannelCommands.............................................................................................................................41
Introduction
PT12Manual 7/20/2021
Page3of48
ChannelSubCommands..................................................................................................................41
5.3.3
ProbeCommands................................................................................................................................43
Calibration...........................................................................................................................................................45
Uncertainty..........................................................................................................................................................46
Specifications.......................................................................................................................................................47
DocumentHistory................................................................................................................................................48
FORSUPPORT,PLEASEEMAILSUPPORT@RHS.COMORCALL(480)9261955WITH
TECHNICALORCALIBRATIONQUESTIONS.

Introduction
PT12Manual 7/20/2021
Page4of48
Introduction
PT12Manual 7/20/2021
Page5of48
INTRODUCTION
ThePT12isahighlypreciseandstableplatinumresistancethermometer(PRT)basedmultichanneltemperature
measurementsystem.Usingacustomdesignedhighprecisionmeasurementcircuitwithfullcurrentreversaland
multiplexedsampling,thePT12provides12channelsoflowuncertaintytemperaturedataforvalidationand
calibration.
Usingoneofthreeautomaticoruserselectablecurrents,thePT12repeatedlyscansall12channels.Employinga
fullreversalcurrentsource,thePT12eliminatespolaritysensitiveerrorsnormallyinherenttoDCmeasuring
techniques.Accuracyisfurtherenhancedbyreferencingallmeasurementstoaseriesofhighaccuracy,
temperaturestableinternalreferenceresistors.
TheintegratedfirmwareallowseachchanneltobeindividuallyprogrammedwithITS90orCallendarVanDusen
(CVD)coefficientsfordirectconversionofresistancemeasurementstotemperature.Itincorporatesafullcolor,
pinchzoomtouchscreenastheuserinterface.Althoughnotrequiredforoperation,thePT12mayalsobe
connectedtoaPCoveranRS232orUSBinterface.
QuickStart/InitialSetup
PT12Manual 7/20/2021
Page6of48
QUICKSTART/INITIALSETUP
Thequickstartisintendedtogetyouupandrunningquickly.Foradditionalinformationseesection4Operation.
2.1 CONNECTINGATEMPERATUREPROBE
Selectanyofthesuppliedprobesandconnectittoanydesiredchannel(theremainderofthissectionwillassume
channel5).Wheninsertingtheplug,ensurethereddotslineup.
StartingUpthePT12
PT12Manual 7/20/2021
Page7of48
STARTINGUPTHEPT12
PlugintheincludedACpoweradaptertoa110240VACoutlet.Plugtheroundconnectorofthepoweradapter
intothebackofthePT12.Asplashscreenshouldappearinabout15secondsandthemachinewillfullyboot
withinabout30seconds.
3.1 OBTAININGAREADING
Oncethesystemfullybootsandtheuserinterfaceispresent,probe5shouldindicateareasonabletemperature
value.Allprobecoefficients(ifasmartprobe)areautomaticallyreadfromtheprobeandappliedtochannel5.
ThePT12hasseveraldifferentdisplaymodes.Itwillpowerupinthepreviousmodethatwasdisplayedonshut
down.Tochangedisplaymodes,swipewithafingerfromthelefthandsidetobringupthemenu.
Fromthismenu,unitsmaybechanged,oranewdisplayformatmaybeselected.
Power(12VDC,3A)USBFlashDriveUSBSerialRS232
Swipe
StartingUpthePT12
PT12Manual 7/20/2021
Page8of48
Toselectadisplaymode,tapthedesiredicon.Themenuwillhide,andthenewdisplaymodewillappear.Forthis
quickstartexample,selectthetopleftdisplaymodeicon(thisisthetemperaturegraphdisplaymode).
Formoreinformationseesection4.3NavigatingtheUserInterface.
StartingUpthePT12
PT12Manual 7/20/2021
Page9of48
3.2 PLOTTINGTEMPERATURE
Toaddaprobe’svaluetothegraph,taptheappropriateprobe(probe5inthiscase)onthetopportionofthe
screen.Theprobe’srecentdatawillbeplottedonthegraph.Toensurethatthedataisvisible,taptheShowAll
graphbuttons,andtheContinuousUpdatebuttontoenablethem.Whenenabled,theyarehighlightedinlight
blue.
Dragasinglefingeronthegraphtoscrollinanydirection.Usetwofingersforpinchzoomoperation.Foradditional
informationongraphfunctions,seesection4.3.1TemperatureGraphDisplayMode
Note:Thegraphonlyretainsthelast48hoursofdata,whilethelogfileholdsallthedatasincethelastpower
cycleorwhenloggingwaslasttoggledon.Seesections4.5FileManagerand4.6SystemInfo.
Operation
PT12Manual 7/20/2021
Page10of48
OPERATION 
ThePT12measurestemperaturebyratiometriccomparisonoftheunknownresistanceofatemperatureprobeto
aseriesoftemperaturestableprecisionreferenceresistors.
Throughcustomselectionofthefourreferenceresistors,thePT12operatingrangeandprecisioncanbetunedfor
either25 PRTsor100 PRTs.Alternatively,itcanbecustomizedtocoverbothrangeswithslightlylessoverall
precision.(Formoreinformationoncustomization,contactRHSystems).ThePT12supportsthreedistinctcurrent
modeswhichcanbemanuallyorautomaticallyselected.Thethreecurrentmodesavailableareapproximately0.3
mA,0.6mA,and1mA.ThePT12willattempttogetthemostaccuratereadingpossiblewhenutilizingautocurrent
mode.
4.1 CONNECTINGTEMPERATUREPROBES
Thereare12LEMOconnectors(oneperprobe)onthePT12andanynumberofprobes(between1and12)maybe
connectedinanyorderatanygiventime.Toconnectaprobe,ensurethereddotsbetweentheplugand
receptaclearealigned,thenpushtoconnect.Pullinguponthebodyoftheplugreleasesthecatch,allowingthe
probetoberemoved.Onceinserted,thePT12willautomaticallydetecttheprobeanddetermineifitisasmart
probe(withinternalconfigurationmemory)orabasicprobe(withoutanymemory).
Operation
PT12Manual 7/20/2021
Page11of48
4.1.1 BASICPROBES
Basicprobesdonothaveinternalmemoryandusethechannel’sconfigurationforcoefficients.Ifyoumoveabasic
probefromonechanneltoanother,youwillhavetomanuallyreentertheprobecoefficients.Pins1and6are
jumperedtogetherinsidetheLEMOplugtoindicateabasicprobe.
Jumper
Wire
Image3.1.1
LEMOF66.1B.306
Basic
Probe
Operation
PT12Manual 7/20/2021
Page12of48
4.1.2 SMARTPROBES
TheLEMOconnectorofeachsmartprobeisembeddedwithaMaximIntegratedDS28EC20‐20Kb1WireEEPROM
chip.Thismemorychipholdstheprobe’scoefficients,serialnumber,andcalibrationdate.Whenasmartprobeis
pluggedin,thePT12automaticallydetectsitandextractsconfigurationinformationfromthechip.Manualentryof
coefficientsisnotrequiredastheconfigurationinformationtravelswiththeproberegardlessofwhichchannelit’s
pluggedinto.
4.1.3 USERSUPPLIEDPROBES
UsersuppliedprobesmaybeutilizedbywiringthemtoaLEMOconnector(part#FGG.1B.306).Tocreateabasic
probe,shortpin1topin6.Tocreateasmartprobe,insertaMaximIntegratedDS28EC20withpin1ofthechipto
pin1oftheLEMOandpin2ofthechiptopin6oftheLEMO.Pin3ofthechipisunusedandshouldbecutoff.See
Image3.1.2above.Bothsmartandbasicprobeswillrequireaninitialentryofcoefficients.Uponsaving,thesmart
probecoefficientswilltravelwiththeprobe.BasicprobecoefficientswillberetainedinthePT12channel.
LEMOF66.1B.306
DS28EC20
Image3.1.2
Operation
PT12Manual 7/20/2021
Page13of48
4.2 CHANNELMEASUREMENTRATE
Ittakesapproximately90msecperreadingforeachoftheattachedprobesandeachofthefourinternalreference
resistors.Meaning,iftwelveprobesareattached,thetotalmeasurementtimetoupdatealltwelvechannelsand
thefourreferenceresistorsisjustunder1.5seconds.Iffewerprobesarepluggedin,unusedchannelsare
automaticallyskipped,increasingmeasurementfrequency.Forexample,withonlyoneattachedprobe,the
approximateupdateratewouldbelessthan0.5seconds.
4.3 NAVIGATINGTHEUSERINTERFACE
ThePT12hasatouchscreeninterfacethatsupportstap,pinch/zoom,swipe,andlongpress.Theyeachhave
differentfunctionsandaresupportedonvariousdisplaymodes.
ThePT12hasseveraldifferentdisplaymodes.Itwillpowerupinthepreviousmodethatwasdisplayedonshut
down.Tochangedisplaymodesswipewithafingerfromthelefthandside.Thisbringsupamenuofavailable
displaymodes.
 
Toselectadisplaymode,tapthedesiredicon.Themenuwillhide,andthenewdisplaymodewillappear.
Thedisplaymodeiconsanddescriptions:
TemperatureGraph:Majorityofthescreenisfilledwithatemperaturegraphwith12small
temperaturevalueslistedabove.
ResistanceGraph:Majorityofthescreenisfilledwitharesistancegraphwith12smallresistance
valueslistedabove.
AllTemperatures:Showsa2x6gridwiththetemperaturesofalltwelveprobes.
Swipe
Operation
PT12Manual 7/20/2021
Page14of48
AllResistances:Showsa2x6gridwiththeresistancesofalltwelveprobes.
4xNumeric:Showsa2x2gridwiththetemperaturesandresistancesofanyfourselectedprobes.
2xNumeric:Showstemperaturesandresistancesinalargefontforanytwoselectedprobes.
Combo:Showsuptotwelveconnectedprobetemperaturesononeside,aminigraph,andalarge
numericvalue(temperatureandresistance)foranysingleprobeselected.
ProbeStatus:ShowstheprobeconnectionstatusofeachchannelofthePT12.
4.3.1 TEMPERATUREGRAPHDISPLAYMODE
Toaddaprobetothegraph,taponitsnumericvalue.Thenumericvaluewillbeoutlinedinaunique
color,andthetemperatureplotwillappearonthegraphinthatsamecolor.
NOTE:Thegraphonlyretainsthelast48hours’worthofdata,whilethelogholdsallthedatasincethelastpower
cycleorwhenloggingwaslasttoggledon.
Operation
PT12Manual 7/20/2021
Page15of48
SCROLLINGTHEGRAPH
Toscrollthegraph,dragafingerinanydirection.Alternatively,toscrollasingleaxis,dragwithintheaxisarea.

Operation
PT12Manual 7/20/2021
Page16of48
ZOOMINGTHEGRAPH
Pinchin/outwithtwofingerstozoomthegraphin/out.
Alternatively,tozoomasingleaxis,longpressontheaxisareathendrag.Foryaxis,dragupordowntozoominor
out.Forxaxis,dragrightorlefttozoominorout.
AXISCONTROL
ShowAll(xaxis):Whilethebuttonisselectedthexaxiswillbescaledtoshowalldata.
ShowAll(yaxis):Whilethebuttonisselectedtheyaxiswillbescaledtoshowalldata.
Fixedyaxis(semiauto):Whilethebuttonisselectedtheyaxisisfixed.Ifthedatagoesoutofboundsthe
yaxisautomaticallyadjuststofitthedata.
Lockedyaxis:Whilethebuttonisselectedtheyaxisremainsexactlyasshownwithoutanyauto
adjustment.
XaxisWidth:Fixesthewidthofthexaxistothespecifiedperiodoftime.
Scrollingdoesnotaffectthisvaluehowever,zoomingoverridesthisvalue.The
numericvaluedisplaysinhours,minutes,orsecondsbasedonitsassociated
dropdownmenu.
ContinuousUpdate:Whilethebuttonisselected,thegraphwillalwaysdisplaythemostrecentvalues,
scrollingthetimeaxisasrequired.Manuallyscrollingorzoomingwilldisablethisbutton.
Operation
PT12Manual 7/20/2021
Page17of48
GRAPHSTATISTICS
Todisplaynumericalstatisticsofanycurrentlygrapheddata,longpressanddragtheboxtohighlightthegraph
datayouwishtoanalyze.Afterreleasing,thestatisticswillbeshownabovethegraph.
Scrollthestatisticaldataleftorrighttodisplaymoreinformation.
Operation
PT12Manual 7/20/2021
Page18of48
4.3.2 RESISTANCEGRAPH
Theresistancedisplaygraphisidenticaltothetemperaturegraphofsection4.3.1TemperatureGraph
DisplayMode,withtheexceptionthatvaluesshownandgraphedareproberesistancesratherthantemperatures.
4.3.3 ALLTEMPERATUREDISPLAYMODE
TheAllTemperatureDisplayModesimultaneouslyshowsalltwelvetemperaturesinthelargestfont
possible.
Unconnectedchannelsappearwithblankvalues.
Operation
PT12Manual 7/20/2021
Page19of48
4.3.4 ALLRESISTANCEDISPLAYMODE
TheAllResistanceDisplayModesimultaneouslyshowsalltwelveresistancesinthelargestfontpossible.
Unconnectedchannelsappearwithblankvalues.
4.3.5 NUMERIC4XDISPLAYMODE
TheNumeric4xDisplayModeshowsanycombinationoffourindividuallyselectablechannels.Eachofthe
fourchannelsmaybeselectedtoshowtemperatureorresistanceinalargefontwhileshowingtheoppositeina
smallerfont.
Operation
PT12Manual 7/20/2021
Page20of48
Toswapaprobe’sindicationfromtemperaturetoresistance,tapitsbottomrightbutton:

Thetemperatureandresistancevalueforthatprobeswapplaces.Totoggleresistancebacktotemperature,tap
thebuttonagain.
Tapthedropdownmenuonanyofthefourchannelstoselectadifferentchannel: 
4.3.6 NUMERIC2XDISPLAYMODE
The2xNumericDisplayModeshowsanycombinationoftwoindividuallyselectablechannels.Eachofthe
twochannelsmaybeselectedtoshowtemperatureorresistanceinthelargestpossiblefont.Operationisidentical
tosection4.3.5Numeric4xDisplayMode.
/