Mobi 70116 User manual

Category
Digital body thermometers
Type
User manual
FEVERTRACK - Ear and Forehead
Thermometer
Model No.: 70116
Instruction Manual
Please read this instruction manual completely before operating.
Package Contents
Quantity
1pc
2pc
1pc
Parts
FEVERTRACK Thermometer
1.5V (AAA) batteries
User Manual
Thermometer Specification
Power Supply:
Body Measuring Range:
Ear and Forehead Measure Accuracy:
Object Measuring Range:
Object Measure Accuracy:
Dimention:
Weight:
Forehead operating Condition:
Ear and Object operating Condition:
Atmosphere pressure:
Service life:
Service life of the battery:
DC 3V (2 x AAA)
89.6°F 109.3°F (32.0°C 42.9°C)
Within range of 95.0°F 107.6°F (35.0°C- 42.0°C):
Accuracy = ±0.4°F (±0.2°C)
Outside of stated range:
Accuracy = ±0.5°F (±0.3°C)
41.0°F 139.8°F (5.0°C - 59.9°C)
±2.0°F (1.0°C)
150.0(L)x40.5(W)x 50.0(H)mm(±2mm)
61.0g (without batteries)
59.0°F 104.0°F (15.0°C 40.0°C)
With a relative humidity of 20% 85%
50.0°F 104.0°F (10.0°C 40.0°C)
With a relative humidity of 20% 85%
700hPa 1060hPa
2 years
6 months based on the use frequency at 5 times/day
Product Specification
1. Forehead Temperature Symbol
2. Ear Temperature Symbol
3. Object Temperature Symbol
4. Low Battery Symbol
5. Temperature Display
6. Celsius/Fahrenheit Symbol
7. Health Check
8. Cleaning Symbol
9. Memory Symbol
10. Temperature Trending Indication
Note: When the device is powered on all icons are temporarily displayed on screen, this is not an
indicator of battery power. Battery indicator will display constantly when battery level is low.
1. Infrared Sensor
2. LCD Display
3. Power & Scan Button
4. Probe Cap
5. MEM/SET Button
6. Temperature Mode Selection
7. Battery Cover
Installing/Replacing Battery
Remove the battery cover by sliding it toward the bottom of the thermometer.
Insert or replace 2 x 1.5 AAA batteries into the battery compartment, ensuring to match the
indicating polarity symbols (always use new batteries).
Replace the battery cover on to the thermometer ensuring it snaps closed.
Temperature Indicators
Temperature Trend Indication Arrows: This indicator helps to easily identify whether the temperature
measurement result is higher or lower than the previous temperature taken. If the temperature rises, the
indicators will light upwards in sequence; if the temperature drops the indicator will light downwards in
sequence, as shown below.
Temperature LED Indication: There are two color LED temperature indicators in this unit. When a
temperature is taken the corresponding light will illuminate around the ‘POWER/SCAN’ button.
Green LED: 34.0°C (93.2°F) - 37.9°C (100.3°F)
Red LED: 38.0°C (100.4°F) - 43.0°C (109.4°F)
Celsius and Fahrenheit Setting
When thermometer is turned on press and hold the ‘MEM/SET’ button until you hear a beep, to
switch between Celsius and Fahrenheit.
Measurement Preparation For Best Results
For more accurate measurements always store the device in same environment it is being used, for
at least 30 minutes prior. An unexpected fluctuation of ambient temperature is likely to lower
measuring accuracy.
External factors may influence ear and forehead temperatures, particularly when the individual has
been:
o Lying on the ear to be measured or has it covered.
o Exposed to very hot or cold temperatures.
o Swimming or bathing causing the ear canal to be wet.
o Recently exercising, bathing or other physical exertion as this increase’s temperature.
Do not talk or move body during measurement.
Make sure to dry forehead or keep ear canal clean. Unclean ear canal or excessive hair may cause
inaccurate reading.
The infrared sensor must be kept clean, dry and undamaged to ensure accurate results. Please wait
5-15 minutes before taking measurement again.
Replace battery when low battery indicator is “ON”.
Use of this device is not intended as a substitution for consultation with your physician.
Measurement results are for reference only. Contact your physician if you have or suspect and
health concerns.
For individuals using hearing aids or ear plugs remove any such device and wait 30 minutes before
taking an ear temperature.
Thermometer Operating Guide
Ear temperature measurement:
Press the ‘SCAN/POWER’ button to turn the thermometer On’.
To measure temperature via ear, remove the forehead probe cover from the unit.
Press the ‘MODE’ button to switch to ear temperature mode, “ ” symbol will be displayed on
screen.
Insert the ear probe tip slightly into the ear opening, then press & release the ‘SCAN’ button to
measure the body temperature.
Once you hear a short beep the body temperature will be displayed. Please allow 6 seconds before
the next reading. The “ ” icon will stop flashing in the display.
Forehead temperature measurement:
To measure temperature via the forehead, ensure forehead probe cover is attached.
Press the ‘MODE’ button to switch to forehead temperature mode ” symbol will be displayed on
screen.
Gently touch the entire tip of the probe to the center of the forehead, midway between the
eyebrows and the hairline. Ensure no hair is obstructing the unit, then press the ‘SCAN’ button, you
will hear a short beep and the temperature will be displayed.
Note: Results shown from 89.6
°
F to 109.4
°
F (32.0
°
C to 43
°
C). HI is displayed for all results above
109.4
°
F (43
°
C), and LO displayed for result below 89.6
°
F (32.0
°
C).
Object temperature measurement:
Remove the forehead cap.
Press the ‘MODE’ button to switch to ‘object’ mode. ” will show up on the display.
Hold the thermometer approximately 1cm away from the object surface, press and release the
‘SCAN’ button aiming the measurement sensor at the object.
Once you hear the short beep the object temperature will be displayed.
Note: If display shows HI/LOW please make sure thermometer is in ‘object’ mode.
Care and Maintenance
Lens / Measurement Sensor
Gently clean with an alcohol swab. Do not use water to wash the thermometer lens directly.
Thermometer
Clean with a soft, dry cloth. Do not use water to rinse the device.
Note: The thermometer is programmed to remind the user to clean the device, ‘ ’ will flash on screen.
Press any button to exit this notification, and please clean the unit.
Health Check
Press buttons MEM/SET and MODE together for 2 seconds to enter the countdown. Use the
MODE button to toggle between 15 minutes, 30 minutes or 45 minutes or OFF.
Press the MEM/SET button when the desired time is on screen to start counting down. When the
countdown is active and running in the background the “ ” sign will flash on screen.
When the countdown begins, the user can press MEM/SET’ and ‘MODE’ button together for 2
seconds to display the remaining time, then press ‘SCAN’ button to return to waiting mode or press
‘MEM/SET’ button to cancel the countdown.
When the countdown is zero. Health check “ ” symbol will display on LCD and the unit will ‘BEEP’ to
remind the user. To stop the notification’s and return to the home menu press any button.
Memory Function
This unit can recall up to 9 prior measurements stored in memory.
Turn on thermometer, press the MEM button once, then press it again to show the last
measurement.
The symbols for ‘EAR’ or ‘FOREHEAD’ will appear with each measurement stored in memory to
indicate whether a person’s forehead or ear temperature was taken.
Each press of the same button recalls a previous measurement.
Troubleshooting
Problem
Checklist
Countermeasure
No response/automatic reset
when pulling out plastic insulator
tab.
Batteries are low or dead
Batteries installed in wrong
polarity?
Poor battery contact?
Change to new batteries
Remove batteries and reinsert
batteries correctly
Measured temperature is lower
than 89.6°F/32.0°F or higher than
109°F/42.9°C
Follow steps in user manual for
correct measurements.
Check the device is in the correct
operating mode.
These Error messages indicate a
problem with the hardware.
Contact Mobi Technologies, Inc.
via contactin information at the
end of this manual.
Operating Temperature is out of
the range
Use the thermometer in the range
of operating conditions
The sensor temperature has not
been stabilised
Wait 10 seconds and take a
measurement again.
The measurement is not accurate
or there is doubt of measurement
results.
Check to see if the infrared sensor
is clean or not.
Clean the infrared senosr with
cotton swab according to the user
manual.
Determine whether your
measuring method is correct or
not.
Please review the user manual
and ensure you are operating the
thermometer correctly.
Assess whether or not you hae
allowed the thermeter and the
patient to become stabilized in the
room for 30 minutes.
Please ensure the thermometer
and patient remain in the location
for at least 30 minutes before
recording a temperature.
Are you using the thermometer
indoors or outdoors.
Always do the measurements
indoors.
Determine if you might have held
the thermometer in your hand too
long which may affect its accuracy.
Place the thermometer in the
room where the measurement is
due to be taken, let it stabilize for
30 minutes before use.
Check to see if the Low Battery
icon is showing on the LCD screen.
Immediately replace the batteries
with new ones.
Product Safety & Warnings
This product was designed to measure human body temperature on the forehead, do not
use this for any other purpose.
Do not use this thermometer if it has been malfunctioning or it has been broken or
damaged.
This product is not waterproof. Do not use this product under any wet conditions and do
not immerse in any liquid or water.
This product should not be left alone with children or pets with not in use by an adult.
Do not store the thermometer in extreme temperatures below (-4°F / -20°C) or over
(131°F/ 55°C).
Do not use the product in a wet ear canal after swimming or bathing. It is possible to
damage the ear canal.
Equipment Symbols
Warning
Compliance with WEEE Standard
Non Sterile Packaging
DO NO THROW AWAY intended for
multiple use
Refer to Operating Instructions
Operating atmospheric pressure
Operating Temperature
Serial number
Operating Humidity
Recyclable
Manufacturer
This device compiles with Part 15
of FCC (federal commuinications
Commission) Rules.
IP22: The first number 2: Protected against solid foreign objects to 12.5mm Φ and greater.
The second number: Protected against vertically falling water drops, when enclosure titled
up to 15°.
Limited Product Warranty
MOBI® warrants its products to be free from defects in material and workmanship for period of (1 Year) from
the date of purchase. Should the product prove to be defective at any time during the warranty period, we
would either replace or repair the product at our option without charge. After the warranty period, a service
charge will apply for replacement of parts and labor costs. To obtain warranty service, you must return the
product complete with its original parts & accessories along with a copy of the original purchase, gift or
registry receipt to us. This warranty does not cover damage caused by any tampering, accident, misuse, abuse,
improper maintenance, unauthorized modification, or connection to an improper power supply. There will be
a charge for repair caused for such damage. This warranty excludes all incidental or consequential damages
and any liability other than stated above.
Questions?
Please visit: www.getmobi.com
Note: For Detailed Instructional Manual please follow this link: http://www.getmobi.com/users-manuals
© 2021 MOBI Technologies, Inc.
All Rights Reserved
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Mobi 70116 User manual

Category
Digital body thermometers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI