Notice
The information contained in this
document is subject to change
without notice and should not
be construed as a commitment by
OAKWORKS®,Inc.
OAKWORKS®,Inc. assumes no
responsibility for any errors that
may appear in this document nor
does it make expressed or implied
warranty of any kind with regard
to this material, including, but not
limited to, the implied warranties
of merchantability and fitness for
aparticular purpose.
OAKWORKS®,Inc. shall not be liable
for incidental or consequential
damages in connection with or
arising out of the furnishing,
performance, or use of this
document and the program
material which it describes.
TABLE OF CONTENTS
i
TABLE OF CONTENTS
Symbol Identification .......................................................................... pg iii
Warnings .............................................................................................. pg iv
Grounding Instructions ......................................................................... pg vi
Introduction .......................................................................................... pg 1
Section I: Product Description & Photo
Celesta GeminiCLODAGH MODEL ............................................. pg 2
Section II: Installation
Leveling Instructions ....................................................... pg 4
Section III: Directions for Use
Celesta GeminiCLODAGH MODEL ............................................. pg 5
Under-Table Cabinet .......................................................... pg 9
Side Arm Rests ................................................................. pg 11
QuickLockFace Rest ........................................................ pg 13
AccessoryOption: Table Extender ................................ pg 15
Moving the Celesta GeminiCLODAGH MODEL ..................... pg 15
Section IV: Troubleshooting
If Table Will Not Change Height or Angle ................... pg 16
Hand Control Replacement Instructions ..................... pg 16
Foot Control Replacement Instructions ....................... pg 19
Section V:Care&Cleaning ................................................................. pg 22
Section VI: Product Identification ...................................................... pg 23
Section VII: Table Specifications......................................................... pg 24
Section VIII: List of Parts ................................................................... pg 25
Section IX: Warranty .................................................................... pg 26
Contact Information ........................................................................... IBC
TABLE OF CONTENTS
ii
SYMBOL IDENTIFICATION
How to Care for Your Upholstery
SYMBOL
IDENTIFICATION
SYMBOL IDENTIFICATION
iii
SYMBOL IDENTIFICATION
SYMBOL
IDENTIFICATION
SYMBOL IDENTIFICATION
This symbol, when used in documentation on this product, represents a caution.
Be sure to read and comply with all precautions and warnings.
This symbol, when used in documentation on this product, indicates danger
and warns against an electrical shock hazard. Be sure to observe and
comply with all warnings and instructions.
This symbol, when used in documentation on this product, indicates a
Protective Earth (Ground) Terminal.
This symbol when used in documentation on this product, warns that dur-
ing transport there should be no stacking of containers.
This symbol, when used in documentation on this product, indicates that
the product should be protected from moisture. The humidity specifications
for Transport & Storage are listed on page 24.
This symbol, when used in documentation on this product indicates that
information is given regarding the recommended temperature limits
during transport and storing. The specifications for these limits are listed
on page 24.
This symbol, when used in documentation on this product, indicates the date
of manufacture of the device.
This symbol, when used in documentation on this product indicates
alternating current (AC).
This symbol, when used in documentation on this product, indicates direct
current (DC).
This symbol, when used in documentation on this product, indicates
that instructional information is included. All instructions should be
read carefully and completely before using the equipment.
~
----
Improper use of this device can cause injury. Be sure to read all
operating instructions prior to use to prevent injury to operator or client.
Electrical Shock Hazard. To reduce the risk of electric shock, always
disconnect the table from the electrical outlet before moving the table
or doing any maintenance or troubleshooting procedures. Never use
this equipment if it has a damaged cord or plug. Use this equipment
only for its intended use as described in these instructions. Do not use
any attachment or accessories not recommended by the manufacturer.
Toreduce the risk of burns, fire, electrical shock or injury:
The power supply/control module is located at the head end of the
table beneath the base. Refer servicing to qualified personnel and
follow manual instructions when doing any authorized troubleshooting.
Before doing any work on the unit, disconnect the power cord from the
power outlet.
Before cleaning with any liquid cleaner be sure to un-plug the power cord
from the power outlet. Do not operate the table in standing water.
Be careful of slack in the power cords as you put the control box back in
the cabinet when troubleshooting to avoid pinching cords between the
cabinet base and the control box bracket.
• Before moving the table, disconnect the power cord from the power
outlet and secure the electrical cord, hand control and foot controls
out of the way for moving.
Risk of Electrical Shock. Connect this table to a properly grounded
outlet only. See Grounding Instructions.
Use this furnishing only for its intended use as described in these
instructions. Do not use attachments not recommended by the manufacturer.
Never operate this table if it has a damaged cord or plug., if it is not
working properly, if it has been dropped or damaged, or dropped into
water. Return the furnishing to a service center for examination and repair.
• Keep the cord away from heated surfaces.
Do not use outdoors.
• Do not operate where aerosol (spray) products are being used or where
oxygen is being administered.
Risk of Injury — Keep children from moving headrest and foot support.
Never drop or insert any object into any opening.
iv
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
How to Care for Your Upholstery
WARNINGS
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
DANGER
READ AND
SAVE THESE
INSTRUCTIONS
WARNING
WARNING
WARNING
v
WARNINGS
WARNINGS
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS(CONT.)
This product is equipped with an interior accessory outlet. The total
electrical load of equipment plugged into this set of outlets is not to
exceed 840 watts.
Close supervision is necessary when this furnishing is used by, or near,
children, invalids or disabled persons. DO NOT leave children alone or allow
them to operate the controls. Keep controls out of reach of children. DO NOT
allow children to crawl into the cabinet or under the table.
Be certain that the table is completely lowered without any tilt being
present prior to discharging an ambulatory patient. The patient may
lose balance and fall. Do not leave clients unattended when table is set at
its highest level.
The table weighs as much as 300 lbs. DO NOT lift or move the unit
without using proper safely procedures or equipment. DO NOT turn
the Celesta Geminion its side for any reason. To do so could cause
damage to the base and will void the warranty. There are no serviceable
items that require this action. Never lift the table by grasping the table top
as the table top is not designed to hold the weight of the base and you
could damage the table.
When operating the Celesta Geminicontrols and making any and all
adjustments to the table, move hands and feet away from the working
mechanism of the table. Use care when opening the doors all the way
so that you do not pinch or injure your fingers. Either arm rest can be
repositioned to allow a client to get on and off the Celesta Geminieasily.
When making adjustments to the arm rests make certain that the client’s
arms are away from the working mechanism.
DO NOT sit on the Arm Rests, the elevated Back Rest or Leg Rest. DO NOT
place excess weight on the Side Arm Rests. DO NOT use them in assisting
the client on and off the Celesta Gemini.
DO NOT put excessive weight or pressure on the QuickLockFace Rest.
Excessive pressure can cause premature failure of the QuickLockFace Rest.
Do Not extend the dowels of the Face Rest further than 3" from the table
edge to ensure a stable connection.
DO NOT use the hand control and the foot control simultaneously as this
can cause damage to one or both units.
DO NOT store or place anything on the cabinet hood under the backrest as
this can cause damage to top and/or hood and will void the warranty.
Maximum Working Load Rating (client and accessories): 625 lbs.
WARNING
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
WARNING
READ AND
SAVE THESE
INSTRUCTIONS
vi
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
GROUNDING INSTRUCTIONS
WARNINGS & SAFETY
INSTRUCTIONS
GROUNDING INSTRUCTIONS
GROUNDING
INSTRUCTIONS
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
GROUNDING INSTRUCTIONS:
This product must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electrical current to
reduce the risk of electric shock. This product is equipped with a cord
having an equipment-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances.
This product is for use on a nominal 120-volt circuit (see below,USA
plug example)and has a grounding plug that looks like the plug
illustrated in Figure A . Make sure that the product is connected to
an outlet having the same configuration as the plug.
No adapter should be used with this product.
GTo remove the accessory from the cabinet: Turn the accessory controls
to the ‘off’ position and then disconnect the unit from the interior
power source by removing the plug from the outlet.
When moving the table: Turn the accessory controls to the ‘off
position, disconnect the table from the exterior power source by
removing the table plug from the outlet.
Correct Implementation Incorrect Implementation
READ AND
SAVE THESE
INSTRUCTIONS
READ AND
SAVE THESE
INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS(CONT.)
WARNING
DANGER-Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a qual-
ified electrician or service man if you are in doubt as to whether the
product is properly grounded. Do not modify the plug provided with
the product - if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
1
INTRODUCTION
Celesta Gemini
INTRODUCTION
INTRODUCTION
Celesta Gemini
Clodagh Model
OAKWORKS®Celesta Geminioffers a variety of positioning capabilities for
massage therapists and skincare professionals of all specialties. On this multi-
functional professional model table the practitioner can perform numer-
ous protocols with ease and comfort. The fully electric Celesta Gemini
is especially effective when professional protocols require specific position-
ing for the client, guest or patient. While the client receives comfortable,
relaxing support, the comfort level of the therapeutic professional is
enhanced by superior ergonomics.
The Celesta Geminishould not be used in any other manner than that
described within this manual. Use of any unnecessary force or unauthorized
procedures could result in injury to practitioner, client or equipment.
Celesta Gemini/Model Clodagh; Model #GMCL
The Celesta Geminiraises, lowers and tilts your clients to the optimal
working height easily with added features provided by an electronically
adjustable flextop and a set of 4 pre-set automatic positions. The variety
of height and reclining positions align the Celesta Geminitop so your
client’s body is at the optimum level for any number of treatments. It features
a single hand control and a foot control to make the precise adjustments
to height, back and knee rest positions to really make it a custom fit to
each client and practitioner.
The cabinet offers an in-cabinet plug-in option to accommodate hot towel
cabinets, placing them right at your fingertips. The large cabinet holds stacks
of towels and other equipment without interfering with the lifts - a problem
many other tables have. The doors slide handily to a fully-open position
for ease of access.
The Celesta Gemini’s bed is built on a solid steel frame for optimum
strength, but you will never know it. The beautiful wood surround makes
the Celesta Geminilook like custom-designed, high-end furniture. You
will rely on the strength, but all you will see is the beauty. We’ve gone to
great lengths to hide the wiring on the Celesta Gemini,for a streamlined
glamour that will accentuate your decor as well as provide ergonomic
benefits and comfort to serve you and your client.
2
PRODUCT DESCRIPTION
Celesta Gemini
PRODUCT DESCRIPTION
PRODUCT
DESCRIPTION
Celesta Gemini-
MODEL CLODAGH
MODEL #:
GMCLMP312572ACUTVN
Total Lifting Capacity:
625 lbs. Maximum Working Load
Quiet height adjustments with the touch of a button
accommodates practitioners and estheticians of all sizes
Electronically adjustable top, controlled by a
multifunctional hand control, allows you to
effortlessly change your clients position while
they relax on the table
Ergonomically designed access top allows the seated
practitioner total ergonomic access to the client’s
head region, reducing strain and fatigue
Four maintenance-free whisper quiet motors
power the electric lift feature
Powered back rest and leg rest make adjustments
easy when a client is on the table
Solid steel frame provides optimum strength.
Fully enclosed cabinet base with doors that slide
all the way open for convenience and ease of access.
3
PRODUCT DESCRIPTION
Celesta Gemini
PRODUCT DESCRIPTION
Table Specs* :
Height *: 25" - 37"
• Width: 31"
Length: 72"
Lift Capacity: 625 lbs Maximum Working Load
Weight: 300 lbs.
Top: Electronically Controlled
Easy Access Design Top
Electronics: 1 Hand Control & 1 Foot Control
• Padding: Aero·CelSystem
Upholstery: Ultratouch II or TerraTouch
Cabinetry: Wood/Maple
For electrical specs, see Specifications Chart, pg 24.
*measurements are determined from floor to top of seat pad using
standardpadding; these measurements can be affected bynatural
material variations in padding
** published weight may differ due to options chosen, natural
material variations and padding density
Celesta Gemini-
MODEL CLODAGH
MODEL # GMCL
Self Adjusting
Removable
Arm Rests (2)
Hand
Control (1)
Sliding Cabinet
doors (2 - access
both sides)
Upholstered
Top
QuickLock™
Face Rest
Access
Design Top
Back Rest
Fully Enclosed
Cabinet Base
-Maple
Exterior
Cabinet
shelf; foot
end only (1)
Foot Control (1)
Vertical
Electronic
Lift Columns (4)
Leg Rest
Seat
PRODUCT
DESCRIPTION
4
INSTALLATION
INSTALLATION
INSTALLATION
Leveling Instructions
The Celesta Geminicomes completely assembled and ready to use. Plug the
cord into a functioning outlet that is rated for the table.
Arrange the power cord and control cords so that they will not create a tripping
hazard. Place the controls in a safe location where they are convenient and
accessible. Keep the controls out of the way of all table mechanisms.
LEVELING INSTRUCTIONS:
If Table Will Not Sit Flat on the Floor:
The Celesta Geminiis equipped with Leveler Feet that adjust to level
the table on uneven floors. To adjust the Leveler Feet to suit common
floor differences you will need to use a 1
/2"open-end wrench or an
adjustable wrench. Adjust each leg individually in turn by adjusting the
height of each leveler foot until the unit rests level and steady. This
adjustment will not effect the function of the table.
1/2" Open-end Wrench
Leveler Foot
CAUTION
The table weighs as much
as 300 lbs.DO NOTlift or
movethe unit without using
proper safely procedures
or equipment. DO NOTturn
the Celesta Geminion its side
for any reason. To do so
could cause damage to the
base and will void the warranty.
There are no serviceable
items that require this action.
Never lift the table by grasp-
ing the table top as the
table top is not designed to
hold the weight of the base
and you could damage the
table.
IMPORTANT
Leveling Feet
When operating the
Celesta Geminicontrols be
sure to observe all cautions
and warnings given in the
manual to prevent injury to
both operator and client.
8
ADJUSTING HEIGHT OF THE TABLE:
The OAKWORKS®Celesta Geminicomes complete with a multifunctional
hand control that operates the height, backrest and leg rest positioning
functions as well as a foot control that operates the height with
electronic ease. These controls should not be used simultaneously
but individually to ensure safety and complete ease of use.
Foot Controls:
Operate the foot control as shown below to raise or lower the height
of the Celesta Gemini.The foot control allows the therapist to adjust
the height function separately from the other functions found on the hand-
control whenever needed. When operating the table’s controls, be sure to
observe all cautions and warnings as given in the manual.
Hand Control: 10 positioning Buttons
The Hand Control on the Celesta Geminioperates all the positioning and tilt
functions available at the touch of a button. The top 4 buttons operate
the customizable positioning of the backrest, seat and leg rest of the
top while the next 2 buttons operate the height of the table. The lower
4buttons activate the pre-set positions of the Access Design flex top.
Follow the directions on the next two pages to access these functions.
5
DIRECTIONS FOR USE
Adjusting Height and Tilt Angle
of the Celesta Geminiusing the Foot Control
DIRECTIONS FOR USE
Foot Control (1):
(used only to change height of table)
UP DOWN
Celesta Gemini
When operating the
Celesta Geminicontrols be
sureto observe all cautions
and warnings given in the
manual to prevent injury to
both operator and client.
CAUTIONS
When operating the
Celesta Geminicontrols and
making any and all adjustments
to the table, move hands, feet
and controls away from any
working mechanisms of the
table.
Children must be supervised
when around this equipment by
aresponsible adult. Do not
leavechildren alone or allow
them to operate the controls.
Do not allowchildren to crawl
into the cabinet or under the
table.
DIRECTIONS FOR USE
Foot Control
CAUTION
DO NOT use the hand
control and the foot control
simultaneously as this can
cause damage to one or
both units.
IMPORTANT
8
6
DIRECTIONS FOR USE
Adjusting Height and Top Positions
of the Celesta Geminiusing the Hand Control
DIRECTIONS FOR USE
Celesta GeminiHAND CONTROL OPERATIONS • Celesta Gemini
Back Rest
Control:
-activates
backrest
up to 64˚
BackRest
Control:
-activates
backrest down
to level position
12
Leg Rest UP Control:
-elevates leg rest
up to 24˚
Leg Rest DOWN
Control:
-lowers leg rest
to level position
CAUTIONS
Do not sit on the elevated
Back Rest or Leg Rest.
Press and hold the appropriate button until the position desired is
achieved and then release. When accessing controls 3 & 4, the leg
position will move in tandem with the thigh section and maintain the
angle of original setting. The arm rests will adjust automatically to
provide the most in comfort and ergonomics while staying parallel
to the floor, no matter what the position.
34
Hand Control
DIRECTIONS FOR USE
Children must be supervised
when around this equipment
by a responsible adult. Do not
leave children alone or allow
them to operate the controls.
Do not allowchildren to crawl
into the cabinet or under the
table.
CAUTION
DO NOT use the hand
control and the foot control
simultaneously as this can
cause damage to one or
both units.
When operating the
Celesta Geminicontrols be
sure to observe all cautions
and warnings given in the
manual to prevent injury to
both operator and client.
IMPORTANT
8
When operating the
Celesta Geminicontrols and
making any and all adjust-
ments to the table, move
hands and feet away from
the working mechanism of
the table.
Height Control:
-raises table height
Height Control:
-lowerstable height
Press and hold the appropriate button until the position desired is
achieved and then release. When accessing controls 3 & 4, the leg
position will move in tandem with the thigh section and maintain the
angle of original setting. The arm rests will adjust automatically to
provide the most in comfort and ergonomics while staying parallel
to the floor, no matter what the position.
56
7
DIRECTIONS FOR USE
Adjusting Height and Top Positions
of the Celesta Geminiusing the Hand Control
DIRECTIONS FOR USE
HAND CONTROL OPERATIONS • Celesta Gemini
Celesta Gemini
Do not leave clients
unattended when table
is set to its highest level.
Hand Control
DIRECTIONS FOR USE
CAUTION
Pre-set
Positions
HAND CONTROL OPERATIONS • Celesta Gemini
Position 5:
-full horizontal position
Position 6:
-Reclined with leg rest
at lowincline
Position 8:
-upright position with leg
rest at mid-incline
Position 7:
-slight recline
with leg rest
at low incline
56
78
Celesta Gemini
Do not leave clients
unattended when table
is set at its highest level.
Close supervision is necessary
when this unit is used by or
near, children, invalids or
disabled persons.
Press and hold the appropriate button until the position desired is
achieved and then release. The arm rests will adjust automatically to
provide the most in comfort and ergonomics while staying parallel
to the floor, no matter what the position.
Hand Control
CAUTION
When operating the
Celesta Geminicontrols and
making any and all adjust-
ments to the table, move
hands and feet away from
the working mechanism of
the table.
Children must always be
supervised when around this
equipment by a responsible
adult. Do not leavechildren
alone or allowthem to operate
the controls. Do not allow
children to crawl into the
cabinet or under the table.
CAUTION
DO NOTuse the hand
control and the foot control
simultaneously as this can
cause damage to one or
both units.
8
DIRECTIONS FOR USE
Adjusting Height and Top Positions
of the Celesta Geminiusing the Hand Control
DIRECTIONS FOR USE
IMPORTANT
8
9
DIRECTIONS FOR USE
Important Safety Note/ Celesta Gemini
Celesta GeminiUnder-Table Cabinet
DIRECTIONS FOR USE
The cabinet hood area under the backrest top is not designed for storage
or as an area to hold accessories while with a client. DO NOT use this
area for holding anything.Damage can occur to the table, especially
when the pre-set position commands that are accessed by the hand control
are activated. Placing anything on this area is prohibiting movement of the
backrest and can cause damage to the table or the object. Using this area as
storage will void the warranty.
DIRECTIONS FOR USE
CAUTION
DO NOT store or place
anything on the cabinet hood
under the backrest as this can
cause damage to the top
and/or hood.
IMPORTANT
8IMPORTANT SAFETY NOTE • Celesta Gemini
UNDER-TABLE CABINET
Under-Table
Cabinet
To Access the Storage in the Under Table Cabinet:
The Celesta Geminihas a fully integrated beautiful wood cabinet and
base. The large under-table cabinet provides storage for stacks of
towels and other equipment without interfering with the lift capacity
of the table. The doors slide all the way open with ease - no need to
fight with double sided doors!
The doors on the under-table cabinet are made of Maple wood and are
hinged on the sides for ease of movement. The doors, 3 on either side
CAUTION
Use care when opening
the doors all the way so
that you do not pinch or
injure your fingers.
Children must always be
supervised when around this
equipment by a responsible
adult. Do not leave children
alone or allowthem to operate
the controls. Do not allow
children to crawl into the
cabinet or under the table.
NOT FOR STORAGE!
To Access the Storage in the Under Table Cabinet: (cont)
of the table, slide independently with slight pressure on the handles
found in the top of each door. They will open to allow access to the
inside the cabinet; stopping when the hinge extends completely.
There are 2 doors that open to a;;ow a larger opening to the interior
with a 3rd door for additional storage. This allows for placement of a
warming cabinet as well as storage for additional towels and supplies.
The Clodagh Model also has an exterior shelf at the foor end of the table
for placing items within easy reach while working.
The Celesta Geminioffers an in-cabinet plug to accommodate hot towel
cabinets. This allows you to store the unit inside with no excess cords to
get in the way.With it plugged in, your towels stay warm and within easy
reach, yet are still out of the way. You will find the plug inside the cabinet
at the head end of the Celesta Gemini.Simply plug the warming cabinet
in and move any excess cord inside the wooden cabinet.
10
DIRECTIONS FOR USE
Celesta GeminiUnder-Table Cabinet
DIRECTIONS FOR USE
UNDER-TABLE CABINET
DIRECTIONS FOR USE
Under-Table
Cabinet (cont)
DANGER
This product is equipped
with an interior 120-volt 60Hz
accessory outlet. Disconnect
all power cords from the
interior power outlet (found
within the cabinet) after use.
The total electrical load of
equipment plugged into this
set of outlets is not to exceed
7amps (840 watts).
Note: Appearance of outlets
will vary depending on
country of use.
CAUTION
Use care when opening the
doors all the way so that you
do not pinch or injure your
fingers.
Children must always be
supervised when around this
equipment by a responsible
adult. Do not leavechildren
alone or allow them to operate
the controls.Do not allow
children to crawl into the
cabinet or under the table.
Keep controls out of reach of
children.
Handles
8
Though the arm rests adjust automatically to remain parallel to the
floor in any position, there will still be times when you will need to
move an arm rest out of the way or remove them altogether. We
recommend that you raise the arm rest out of the way to allow a client to
get on or off the table. They are designed to be strong and will take a
reasonable amount of weight but they are not designed to be used to
sustain a person’s weight when getting on or off the table.
To Adjust the Arm Rest:
Before asking a client to mount or dismount from the table we recommend
that you move the arm rest out of the way. The arm rests are easy to move
and manually adjust. First position the tabletop with the backrest in the
upright position and all other section flat. Take hold of the arm rest
firmly and raise the arm rest up and out of the way with a steady swing
until the arm rest is in the highest upright position (see images below).
Hold it in place until your client has mounted (or dismounted)and then
actively move it back into the resting position where it will proceed to
move automatically with the table top.
The arm rest is now set and will adjust automatically as you position the
client for whatever procedure is needed.
There will be times when removal of the arm rests will be needed. This
feature is helpful when doing massage or helping someone get on or off
the Celesta Gemini.This can be done easily and storage is conveniently
located in the under-table cabinet. They are then right at hand when you
are ready to re-install.
ToRemove the Arm Rest:
The arm rest frame has a notched connection to the interior of the the
table top which allows it to move automatically when the table top
changes position. (cont. on next page)
11
DIRECTIONS FOR USE
Use & Adjustment of the Celesta GeminiArm Rests
DIRECTIONS FOR USE
DIRECTIONS FOR USE
Do not place excess
weight on the Side Arm
Rests. Do not use them in
assisting the client on and
offthe Celesta Gemini.
Either Arm Rest can be
repositioned to allow a
client to get on and off
the Celesta Geminieasily.
When making adjustments
the arm rests make certain
that the client’s arms are
away from the working
mechanism.
CAUTION
Do not sit on the Arm Rests.
SIDE ARMRESTS:
Be sure to read all
cautions, warnings
and instructions given
in the manual to prevent
injury to both operator
and client.
Side Arm Rests
Adjusting the Side Arm Rest
IMPORTANT
8
12
DIRECTIONS FOR USE
Use & Adjustment of the Celesta GeminiArm Rests
DIRECTIONS FOR USE
DIRECTIONS FOR USE
To remove one or both arm rests just take hold of the base of the arm
rest at the metal frame and somewhere on the cushion. Holding secure-
ly, rotate the arm rest while at the same time pulling slightly away
from the table. You will feel the notched connection slide out as you
rotate the arm rest. When you feel this you can then slide the entire arm
rest out of the connection hole very easily. Store it safely inside the
under-table cabinet until ready for installation.
Re-attach the armrest by sliding the arm rest frame into the hole on the
tabletop and rotating the it until you feel the notch slip into place. Push
it in securely and allow the arm rest to rest in the parallel position. This
resets the arm rest in the proper position for the automatic adjustment
feature to be activated.
Removing the Side Arm Rests
Do not place excess weight
on the Side ArmRests. DO
NOT use them in assisting
the client on and off the
Celesta Gemini.
Either arm rest can be
repositioned to allow a
client to get on and off the
Celesta Gemini.easily.
When making adjustments
to the arm rests make
certain that the client’s
arms areaway from the
working mechanism.
CAUTION
Do not sit on the Arm Rests.
SIDE ARM RESTS: (CONT.)
Side Arm Rests
(cont.)
IMPORTANT
8
If you have purchased the optional manicure arm rest please follow the
standard installation and removal instructions above.
OPTIONAL MANICURE ARM RESTS:
A. hand soak bowl installation
B. hand soak bowl removal
C. Manicure surface installation AB C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

OAKWORKS Celesta Gemini CLODAGH User manual

Category
Massagers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI