REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 3 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
2
3
2.1 Determine the location of where the fixture(s) will be installed. Mounting brackets should be spaced 4” from each end of the fixture(s) and also every
24” in between to evenly distribute weight.
2.2 Slide the square nuts through the
slot on the backside of the recessed
channel. Please note, make sure to
not install any end caps (powered
or blank) before these square nuts
are slotted through the back of the
extrusion.
2.4 Tighten the 10-32 x 1/4” hex head screws
through the recessed spring brackets and into
the square nuts, securing the recessed spring
brackets to the backside of the recessed track
housing.
2.3 Bring down the recessed spring brackets to
the backside of the recessed channel and
line the holes up with the square nuts from the
previous step. Please make sure the spring
brackets alternate in direction.
3.1 Slide on the Endcap 3.2 Tighten the set screw.
Luminii recommends not to exceed 24ft or 3 track joiners per power feed to minimize system voltage drop and avoid output variation across the run.
Long runs of track can be accomplished using multiple power feeds. See page 8 for details on converting a joiner to a power feed using accessory
TJ-1-72.
Mounting Bracket Installation – MB-STR
Blank Endcap Installation – EC-STR-H3-XX
4” 24”
fixed clip
spring bracket
recessed track housing
hex head screw
set screw
3 .1
3.2