4 ba76133e04 03/2015
P700IQ
3.3.6 Connecting the lines. . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.3.6.1 Connecting the IQ S
ENSORNET cable to the
MIQ//WCA 232 . . . . . . . . . . . . . . . . . . . . . . . . 39
3.3.6.2 Connecting the power line and heat tracing lines
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.3.6.3 Connecting the liquid containers . . . . . . . . . . 43
3.4 Initial commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4 Measuring / Operation
4.1 Measuring operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
4.1.1 Determination of measured values . . . . . . . . . . . . . . . 49
4.1.2 Starting the measuring operation. . . . . . . . . . . . . . . . . 49
4.1.3 Measuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4.1.4 Settings for the P 700 IQ . . . . . . . . . . . . . . . . . . . . . . . 51
4.2 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.2.2 1-point calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.2.3 2-point calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.2.4 Calibration history . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
4.2.5 Reactivating the last valid calibration. . . . . . . . . . . . . . 62
5 Maintenance and cleaning
5.1 Hazard warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
5.2 Consumables, accessories, replacement parts . . . . . . . . . 65
5.3 Maintenance and cleaning activities (general steps) . . . . 68
5.3.1 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
5.3.2 Calibration and service menu (SERVICE menu) . . . . . 69
5.3.3 Maintenance and cleaning work on the closed
P 700 IQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
5.3.4 Maintenance and cleaning work on the open P 700 IQ 74
5.4 Carrying out the maintenance and cleaning activities . . . 77
5.4.1 Changing the liquid containers. . . . . . . . . . . . . . . . . . . 77
5.4.2 Checking the climate kit (if available). . . . . . . . . . . . . . 78
5.4.3 Changing the filter mats . . . . . . . . . . . . . . . . . . . . . . . . 80
5.4.4 Changing the tube set (T SET) . . . . . . . . . . . . . . . . . . 81
5.4.5 Changing the pump tube of the peristaltic pump . . . 85
5.4.6 Cleaning the filter membrane. . . . . . . . . . . . . . . . . . . . 90
5.4.6.1 Mechanical cleaning. . . . . . . . . . . . . . . . . . . . 91
5.4.6.2 Chemical cleaning . . . . . . . . . . . . . . . . . . . . . 92
5.4.7 Exchanging the filter membrane . . . . . . . . . . . . . . . . . 94
5.4.8 Storing a used filter membrane . . . . . . . . . . . . . . . . . . 95
5.4.9 Cleaning the overflow vessel . . . . . . . . . . . . . . . . . . . . 95
5.4.10 Cleaning the suction tube of the sample filtration . . . . 96
5.4.11 Performing a Hydraulic check . . . . . . . . . . . . . . . . . . . 99
5.4.12 Performing an LED Check . . . . . . . . . . . . . . . . . . . . . 100