Asus Pentium 4 1U Rackmount Server AP160R-S User manual

Category
Servers
Type
User manual

This manual is also suitable for

Pentium
®
4 1U Rackmount Server
AP160R-S
User Guide
2
Disclaimer/Copyrights
No part of this manual, including the products and software described in it, may be reproduced,
transmitted, transcribed, stored in a retrieval system, or translated into any language in any
form or by any means, except documentation kept by the purchaser for backup purposes, without
the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES
OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE
LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
(INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR
DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN
THIS MANUAL OR PRODUCT.
Product warranty or service will not be extended if: (1) the product is repaired, modified or
altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the
serial number of the product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks
or copyrights of their respective companies, and are used only for identification or explanation
and to the owners’ benefit, without intent to infringe.
The product name and revision number are both printed on the product itself. Manual revisions
are released for each product design represented by the digit before and after the period of the
manual revision number. Manual updates are represented by the third digit in the manual revision
number.
For previous or updated manuals, BIOS, drivers, or product release information, contact ASUS
at http://www.asus.com.tw or through any of the means indicated on the following page.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED
FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT
NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS
ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES
THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE
DESCRIBED IN IT.
Copyright © 2002 ASUSTeK COMPUTER INC. All Rights Reserved.
Product Name: ASUS AP160R-S
Manual Revision: 1.01 E1068
Release Date: July 2002
3
Contents
Disclaimer/Copyrights ................................................................. 2
ASUS Contact Information .......................................................... 5
FCC/CDC Statements ................................................................... 6
Safety Precautions ....................................................................... 7
Introduction: About This Manual ......................... 9
Audience ..................................................................................... 10
Contents ...................................................................................... 10
Conventions.................................................................................11
References ...................................................................................11
System Package Contents ........................................................ 12
Chapter 1: System Overview............................. 13
1.1 System Features................................................................ 14
1.2 Front Panel Features......................................................... 15
1.3 Rear Panel Features.......................................................... 15
1.4 Internal Features ............................................................... 16
Chapter 2: Hardware Setup ............................... 17
2.1 Removing and installing the chassis cover.................... 18
Removing the cover ............................................................ 18
Installing the cover .............................................................. 18
2.2 Motherboard Placement ................................................... 19
Placement Direction ............................................................ 19
Motherboard Screws ........................................................... 19
2.3 Installing a CPU ................................................................. 20
CPU Orientation .................................................................. 20
CPU Socket Location .......................................................... 20
Unlock the CPU Socket....................................................... 21
Insert the CPU..................................................................... 21
Secure the CPU .................................................................. 21
Install the Heatsink .............................................................. 22
2.4 Installing system memory ................................................ 23
DIMM sockets location ........................................................ 23
Install a DIMM ..................................................................... 23
4
Contents
2.5 Installing the backplane and bridge boards ................... 24
Bridge board........................................................................ 24
Backplane board ................................................................. 25
2.6 Installing a hard disk drive ............................................... 26
2.7 Installing a PCI card .......................................................... 28
2.8 Installing the front bezel and rack ears........................... 30
2.9 Installing CD-ROM and floppy drives .............................. 31
Chapter 3: Hardware Options ........................... 33
3.1 Cooling System ................................................................. 34
Fan locations ....................................................................... 34
Fan connectors.................................................................... 34
Fan cable connections ........................................................ 35
Removing the fans .............................................................. 36
3.2 Power connections ........................................................... 37
3.3 Removing the power supply ............................................ 38
Appendix A: Power Supply ................................ 39
A.1 General Description .......................................................... 40
A.2 Specifications .................................................................... 41
Input Characteristics............................................................ 41
Output Characteristics......................................................... 41
Over-Voltage Protection (OVP) ........................................... 41
Appendix B: Troubleshooting............................ 43
B.1 Simple Fixes ...................................................................... 44
5
ASUS Contact Information
ASUSTeK COMPUTER INC. (Asia-Pacific)
Address: 150 Li-Te Road, Peitou, Taipei, Taiwan 112
General Tel: +886-2-2894-3447
General Fax: +886-2-2894-3449
General Email: [email protected]
Technical Support
MB/Others (Tel): +886-2-2890-7121 (English)
Notebook (Tel): +886-2-2890-7122 (English)
Desktop/Server (Tel): +886-2-2890-7123 (English)
Support Fax: +886-2-2890-7698
Support Email: [email protected]
Web Site: www.asus.com.tw
Newsgroup: cscnews.asus.com.tw
ASUS COMPUTER INTERNATIONAL (America)
Address: 6737 Mowry Avenue, Mowry Business Center,
Building 2, Newark, CA 94560, USA
General Fax: +1-510-608-4555
General Email: [email protected]
Technical Support
Support Fax: +1-510-608-4555
General Support: +1-502-995-0883
Web Site: www.asus.com
Support Email: [email protected]
ASUS COMPUTER GmbH (Europe)
Address: Harkortstr. 25, 40880 Ratingen, BRD, Germany
General Fax: +49-2102-442066
General Email: [email protected] (for marketing requests only)
Technical Support
Support Hotline: MB/Others: +49-2102-9599-0
Notebook (Tel): +49-2102-9599-10
Support Fax: +49-2102-9599-11
Support (Email): www.asuscom.de/de/support (for online support)
Web Site: www.asuscom.de
6
FCC/CDC Statements
Federal Communications Commission Statement
This device complies with FCC Rules Part 15. Operation is subject to the following
two conditions:
This device may not cause harmful interference, and
This device must accept any interference received including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with manufacturer’s instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING! The use of shielded cables for connection of the monitor to the
graphics card is required to assure compliance with FCC regulations. Changes
or modifications to this unit not expressly approved by the party responsible
for compliance could void the users authority to operate this equipment.
Canadian Department of Communications Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions
from digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
This class B digital apparatus complies with Canadian ICES-003.
7
Safety Precautions
Electrical Safety
Operation Safety
IMPORTANT
Before installing or removing signal cables, ensure that the power
cables for the system unit and all attached devices are unplugged.
To prevent electrical shock hazard, disconnect the power cable from
the electrical outlet before relocating the system.
When adding or removing any additional devices to or from the
system, ensure that the power cables for the devices are unplugged
before the signal cables are connected. If possible, disconnect all
power cables from the existing system before you add a device.
If the power supply is broken, do not try to fix it by yourself. Contact
a qualified service technician or your dealer.
Any mechanical operation on this server must be conducted by
certified or experienced engineers.
Before operating the server, carefully read all the manuals
included with the server package.
Before using the server, make sure all cables are correctly
connected and the power cables are not damaged. If any
damage is detected, contact your dealer as soon as possible.
To avoid short circuits, keep paper clips, screws, and staples
away from connectors, slots, sockets and circuitry.
Avoid dust, humidity, and temperature extremes. Place the
server on a stable surface.
IMPORTANT
This product is equipped with a three-wire power cable and
plug for the users safety. Use the power cable with a properly
grounded electrical outlet to avoid electrical shock.
CAUTION
8
9
ASUS AP160R-S 1U Rackmount Server
Introduction
About this guide
About This Guide introduces the contents
of this document. This part includes the target
audience, chapter description, and
conventions used. It also lists other sources
of information that are not contained in this
manual.
10
Introduction: About this guide
Audience
Contents
This guide contains the following parts:
1. Introduction: About this guide
This part introduces the contents of this document. It includes the target
audience, chapter description, and conventions used. It also lists other
sources of information that are not contained in this manual.
2. Chapter 1: System overview
This chapter describes the general features of the AP160R-S server. It
includes sections on front panel and rear panel specifications.
3. Chapter 2: Hardware setup
This chapter lists the hardware setup procedures that you have to perform
when installing system components.
4. Chapter 3: Hardware options
This chapter describes the optional hardware procedures that you may
have to do when configuring the system.
5. Appendix A: Power supply information
This appendix gives information on the 200-watt switching power supply
that came with the AP160R-S server.
6. Appendix B: Troubleshooting
This appendix lists the common problems that you may encounter while
using the AP160R-S server. It lists the possible causes of the problems
and offers solutions. You may refer to this part and try to solve simple
problems before calling customer support.
This user guide is intended for system integrators, and experienced users
with at least basic knowledge of configuring an entry-level server.
ASUS AP160R-S 1U Rackmount Server
11
Conventions
Symbols
To make sure that you perform certain tasks properly, take note of the following
symbols used throughout this manual.
WARNING: Information to prevent injury to yourself when trying to
complete a task.
CAUTION: Information to prevent damage to the components when
trying to complete a task.
IMPORTANT: Information that you MUST follow to complete a task.
NOTE: Tips and information to aid in completing a task.
References
Refer to the following sources for additional information and for product and
software updates.
1. ASUS NR-LSR Motherboard Users Manual
This manual contains detailed information about the NR-LSR
motherboard.
2. ASUS Websites
The ASUS websites worldwide provide updated information on ASUS
hardware and softare products. The ASUS websites are listed in the ASUS
Contact Information on page 5.
3. Optional Documentation
Your product package may include optional documentation such as a
CD-ROM manual, warranty flyers, and others that may have been added
by your dealer. NOTE: These documents are not part of the standard
server package.
12
Introduction: About this guide
System Package Contents
The following checklist enumerates the components included in the standard
system package.
1) ASUS 1U chassis (AR-12)
2) ASUS NR-LSR motherboard
3) 284W power supply
4) Backplane board (BP4LS-AR12)
5) PCI riser card (PCI64-3V-AR12)
6) Bridge board (BRIDGE-AR12)
7) Bridge board for SCSI RAID (BRIDGE/S-AR12)
8) 40x40x28 mm system fans (3 units)
9) Two fan modules each composed of 4 units of 40x40x28 mm fans
10) Front bezel and mounting ears
11) ASUS 1U rail kit
12) CPU heatsink
13) SCSI HDD trays (4 units)
14) Support CD that includes drivers, utilities, and ASUS Server
Web-based Management (ASWM)
15) User guides (for system and motherboard)
If any of the above items is missing, contact your dealer.
NOTE
13
ASUS AP160R-S 1U Rackmount Server
This chapter describes the general features
of the AP160R-S server. It includes sections
on front panel, rear panel, and internal
features of the server.
Chapter 1
System Overview
14
Chapter 1: System Overview
1.1 System Features
The ASUS AP160R-S is a stylish barebone server featuring the ASUS
NR-LSR motherboard. The server supports the Intel
®
Pentium
®
4 processor
in a 478-pin socket, and includes the latest I/O, and video technologies through
the chipsets embedded on the motherboard.
Following are highlights of the server’s many features.
Processor: Support for Intel
®
Pentium 4 processor with 400MHz FSB
and 512KB L2 cache
Memory: Four DIMM sockets support up to 8GB of system memory
using registered ECC PC2100/PC1600 DDR DIMMs
System Chipset: The Serverworks
®
Grand Champion Low End (GCLE)
SystemSet includes the Champion Memory and I/O Controller LE
(CMIC-LE) as the host bridge, the Champion South Bridge (CSB5) as a
PCI to Low Pin Count (LPC) bridge, and the Champion I/O Bridge
(CIOB-X2) that provides a high performance data flow path between
the IMB and the I/O subsystem.
LAN Chipsets: The Intel
®
82544GC Gigabit Ethernet controller is an
integrated Ethernet LAN component that supports 1000Mbps, 100Mbps,
and 10Mbps data rates. The Intel 82550 Fast Ethernet controller fully
supports 10BASE-T/100BASE-TX networking protocols.
SCSI Chipset: The LSI
®
53C1010R SCSI controller supports up to 30
Ultra-160 SCSI devices through the onboard dual-channel SCSI
connectors.
VGA Chipset: The ATI
®
Rage-XL PCI-based VGA controller supports
up to 8MB PC-100 display SDRAM for 1280x1024 and true color
resolutions.
Storage: Four 1” height, 3.5-inch width HDD drive bays
Expansion: Two full-length 64-bit 133/100MHz PCI-X slots on a
proprietary riser card.
Power Supply: 115Vac/230Vac 284-watt auto-switching power supply
ASUS AP160R-S 1U Rackmount Server
15
1.2 Front Panel Features
The front panel of the server allows easy access to the hard disk drives. The
power and reset buttons, LED indicators, and the 68-pin connector for the
Combo module are also located on the front panel.
1.3 Rear Panel Features
The server rear panel includes the connectors, the system devices, and two
slots for expansion cards.
Power supply fan
PS/2 mouse port
AC Power socket
Serial port (COM1)
Rear fan
100/10Mbps LAN port
Power supply fan
PS/2 keyboard port
LAN port ( for Server
Management)
VGA port
Very High-density SCSI
connector (VHDCI)
USB ports
Location switch
Location LED
Gigabit LAN port
HDD power LEDs
HDD access LED
LAN LEDs
Front USB
connector
68-pin combo drive
cage connector
Message LED
Reset button
Location LED
Location Switch
Power LED
Power button
Combo module
rail hole
Combo module
rail hole
16
Chapter 1: System Overview
1.4 Internal Features
The standard components inside the AP160R-S server include the
motherboard, backplane, bridge board, fans and fan modules, PCI riser card
assembly, and power supply. The pictures below show the standard
components of the server.
1. HDD bays
2. Backplane (underneath)
3. Bridge board
4. 1 x 40mm PCI fan
5. 8 x 40mm System fan
6. 1 x 40mm PSU fan
7. Copper CPU heatsink
8. NR-LSR motherboard
9. 4 x DIMM sockets
10. 1 x 40mm rear fan
11. 2 x PSU fan
12. 284W PSU
1
2
4
3
6
12
9
10
11
11
1
7
5
8
The PCI riser card and card bracket assembly is not shown installed
in the above picture. Refer to section 2.7 Installing a PCI card
for more details on the riser card.
NOTE
17
ASUS AP160R-S 1U Rackmount Server
This chapter describes the hardware setup
procedures that you have to perform when
installing system components.
Chapter 2
Hardware Setup
18
Chapter 2: Hardware Setup
2.1 Removing and installing the chassis cover
Removing the cover
1. To release the cover, push the
two latches outward, then
slide the cover towards the
rear for about half an inch.
2. Lift the cover from the chassis.
Installing the cover
1. Place the cover on top of the
chassis leaving about half an
inch gap from the front edge.
2. Firmly hold down the cover and
you slide it towards the front
until it fits in place.
Half-inch gap
ASUS AP160R-S 1U Rackmount Server
19
Placement Direction
When installing the motherboard,
make sure that you place it into the
chassis correctly. The edge with the
external ports goes to the rear part
of the chassis.
Motherboard Screws
Place seven (7) screws in the holes
indicated by circles to secure the
motherboard to the chassis. Do not
overtighten the screws. Doing so
may damage the motherboard.
2.2 Motherboard Placement
The motherboard and other internal components of the AP160R-
S server are already installed as indicated in section
“1.4 Internal
Features”
. Refer to the motherboard user’s manual for detailed
technical information about the motherboard.
NOTE
You must remove the protruding screws (indicated by black circles
above) on the serial port, VGA port, and high-density SCSI
connector before installing or removing the motherboard.
Otherwise, you cannot properly install or remove the motherboard.
NOTE
Place this side
towards the rear
of the chassis
20
Chapter 2: Hardware Setup
2.3 Installing a CPU
The 478-pin Zero Insertion Force (ZIF) socket on the NR-LSR motherboard
supports an Intel Pentium 4 processor. This section tells you how to install a
CPU. Refer to the motherboard user guide for more information.
CPU Socket Location
Locate the 478-pin CPU socket and
note the Pin 1 location.
CPU Orientation
A CPU has a mark (usually a notch
or a gold mark) on one corner to help
you identify the correct orientation
when inserting it to the socket.
Match the marked corner of the CPU
to Pin 1 on the socket.
Incorrect installation of the CPU into the socket may bend the pins
and severely damage the CPU!
CAUTION
Gold Mark
Pin 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Asus Pentium 4 1U Rackmount Server AP160R-S User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI