MiLAN MIL-RM3U Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide
To Contact Technical Support:
For prompt response when calling for technical support, have the following information 
ready: product serial number, date of purchase, vendor or place of purchase.
Contact one of the following:
In North America: call +1.408.744.2751 or email: supp[email protected]
International: call +49.231.97.47.780 or email: [email protected]
© 2000 MiLAN, the MiLAN logo, and MiLAN Technology are either trademarks or registered trademarks of Digi International,
Inc. in the United States and/or other countries. All other trademarks are the property of their respective holders.
Package Contents
• MIL-RM3U rack mount unit
• 17.5" tie wrap
• Seven, 6-32 X 1 philip-head screws
Introduction
The MIL-RM3U is a six slot rack mount assembly, which fits into a standard 3U
rack (there will be a 3/4" gap from the top of the unit to the next device up). The
device is capable of supporting up to six media converters and transceivers,
including MiLAN's MIL-225, MIL-240, and MIL-250. A power supply is included
(located at the rear of the MIL-RM3U).
Features
• Dimensions: 19" (W) X 4.5" (H) X 8.75" (D)
• Back panel, with power supply and access to the media converters
• Autosensing power supply: 110/220 VAC with an
IEC connector
Installation
1. Remove the assembled base, cover, and bag of screws from the shipping box.
2. Unravel the power cord and make sure it is able to reach an AC outlet when 
the MIL-RM3U is finally installed into a standard 19" rack.
3. Install the first media converter/tranceiver into the slot nearest the
power supply.
Note: Make any adjustments to the converter/transceiver "before" installing the
device into the MIL-RM3U.
4. Connect the cord connector from the power supply into the power receptacle 
on the converter/tranceiver. Do this for each device installed into the
MIL-RM3U.
5. Install any other converter/transceiver into the MIL-RM3U.
6. Attach the cover of the unit to the base assembly. Use the screws supplied.
7. Install the MIL-RM3U into a 19" rack. Refer to the 19" rack's documentation for 
instructions on installing the MIL-RM3U.
8. Use the tie wrap to secure and store the power supply cord
Five-Year Limited Warranty
MiLAN Technology warrants to the original consumer or purchaser that each of its products,
and all components thereof, will be free from defects in material and/or workmanship for a
period of five years from the original factory shipment date. Any warranty hereunder is
extended to the original consumer or purchaser and is not assignable.
MiLAN Technology makes no express or implied warranties including, but not limited to, any
implied warranty of merchantability or fitness for a particular purpose, except as expressly set
forth in this warranty. In no event shall MiLAN Technology be liable for incidental or
consequential damages, costs, or expenses arising out of or in connection with the
performance of the product delivered hereunder. MiLAN Technology will in no case cover
damages arising out of the product being used in a negligent fashion or manner.
MIL-RM3U
Rack Mount
Installation Guide
MODEL: MIL-RM3U
Installation Guide
90000041 REV. B Printed in the USA
2 3
MiLAN Technology
1299 Orleans Dr.
Sunnyvale, CA 94089
Voice: 408.744.2775
FAX: 408.744.2793
Figure 1. MIL-RM3U Rack Mount
  • Page 1 1

MiLAN MIL-RM3U Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI