- INSTALLATION & OPERATION INSTRUCTIONS -
The RY-ES is a relay used to activate an external signaling device when the door station calls in. It
can be used for call extension on the JK, JF, JA, KC, KB, AX, NEM, DB, and IE systems. The relay
connects to the chime output of the master in place of the IER-2. The system’s power supply
powers the input of the RY-ES relay. A separate power source is required for the external device.
Output of relay:
2 Orange wires
N/O Dry contact closure
Input of relay:
Red: Positive Power
Black: Negative Power
White: Activation wire*
Blue: Activation wire*
*Blue & White are Non-polarized
1 NAMES & FUNCTIONS
RY-ES
2 INSTALLATION
RY-ES
Wall mount the unit with the
supplied mounting hardware as
shown in the diagram to the left.
When making wire connections,
be sure not to short any wires
together. Use wire nuts or
another protective material to
isolate the connections.
Pg. 1
0710
+
-
RY-ES
Blue
Orange
1A1
1A2
B1
B2
S
S
L
L
+
-
DOOR
SUB OUT
CALL EXT
A1
A2
3 WIRING DIAGRAMS
PS-1820UL
JK-1MD/JK-1MED
JF-2MED
Door
External Device
and Power
JK & JF Systems
JA System
DOOR 1
SUB
JA-2MCD/-2MECD
A1
A2
Door
+
-
A1
A2
B1
B2
A1
A2
Purp
Blu
Grn
Yel
Org
Red
Brn
S
S
Brn
Red
Org
Yel
#2
#1
C1
C2
C1
C2
DOOR 2
ADAPTER
1
ADAPTER
2
CALL EXT
+
-
PS-2420UL
External Device
and Power
Pg. 2
White
Red
Black
RY-ES
Blue
Orange
White
Red
Black
NP
NP
3 WIRING DIAGRAMS (cont)
+
-
Door
1A1
1A2 B2
+
-
S
S
B1
KB & KC Systems
KB-3MRD/
KC-1GRD
A1
A2
PS-2420UL
External Device
and Power
AX System
Orange
Yellow
AX-8M/AX-8MV
D
1
D
3
D
5
D
7
D
2
D
4
D
6
D
8
DOOR RELEASE RELAY
L
1
L
2
L
3
L
4
L
5
L
6
L
7
L
8
M
1
M
3
M
2
M
4
VCH
1
VCH
2
X
1
OUT X
2
AX
-
320
C
CO
+
-
+
-
D
-
PS V
-
PS
RS
-
232
C
POWER
VIDEO OUT
V
1
V
2
AIPHONE
AX
-
084
C
+
-
PS
-
2420
UL
+
-
PS
-
2420
UL
Cat5e
Cat5e
RY-ES
External Device
and Power
Orange
Blue
White
Red
Black
Pg. 3
RY-ES
Blue
Orange
White
Red
Black
NP
NP
3 WIRING DIAGRAMS (cont)
NEM System
A
B
C
D/E
1
~
10
E
S
+
-
+
-
PS-2420UL
NA-A NEM-10/C
External Device
and Power
4 SPECIFICATIONS
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT: (800) 692-0200
Pg. 4
RY-ES Instr.
0710JD
Power Source: 12-24V DC, 12-16V AC. Power supplied by master.
Current consumption: DC: Standby 10mA. Max 120mA
AC: Standby 15mA. Max 140mA
Contact rating: 125V AC 1.0A
30V DC 1.0A
D
E
B1
B2
B3
B4
BL+
BL-
~ ~
15V
~ ~
DA-1DS
PT-1211C
DB-1MD
Org
Yel
D
E
L
L
DB System IE System
RY-ES
External Device
and Power
Orange
Blue
White
Red
Black
D1
E1
(D2)
(E2)
T
R
C
E
+
-
1
2
IE Door
Station
IE-1GD
IE-2AD
~
~
PT-1210N
External Device
and Power
RY-ES
Blue
Orange
White
Red
Black
RY-ES
Blue
Orange
White
Red
Black
NP
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Aiphone RY-ES User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI