MOUNTING INSTRUCTIONS
6-PIN CONNECTOR
0803 A
http://www.aiphone.com/
Printed in Thailand
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE EUROPE N.V., ANTWERP, BELGIUM
■ MOUNTING
1.Take the mounting bracket off of the monitor unit.
2.Cut out the cable knock-out, as shown by the dotted lines.
3.Plug the 6-pin connector into slot.
4.Connect the wires to the terminal block. Attach the protection shield.
5.Attach the mounting bracket to a box. Mount the monotor unit onto the bracket.
1
4 5
1 65432
2
3
Strip jacket of cable. Put all
the wires neatly into slot to
avoid damage by pinching.
{
{
{
FOR MODELS FUNCTION (WIRE)
MK-1GD, MK-1HD, Ext. device control (Gray)
MK-2MCD, MK-2HCD porch light, etc. (Gray)
MK-2MCD
b1RY-3DL (Orange)
b2RY-3DL (Yellow)
MK-1GD, MK-2MCD
VIDEO
-
(White)
VIDEO + (Blue)
1A1
1A2
+
L
L
DC18V
RLSE.
DOOR1
2A1
2A2
DOOR2
6PIN CONNECT OR WIRING DIAGRAM
for MK-2MCD & MK-1GD
RY-3DL
EL-9S
AC Trans.
L1
C1
L2
C2
L3
C3
b1
b2
b3
D1
D2
E
EL-9S
MK-DBC
Master
MK-2MCD
Sub
MK-2HCD
2
4
4
PS18
MK
-
DG
C
2
PS24
: PS-1820DIN, PS-1820S, PS-1820UL (2A)
RY-3DL
EL-9S
EL-9S
5
PT
MAW-B
Sub
MK-2HCD
WHITE
RED(+)
BLACK(–)
OR
AN
GE
O
R
AN
G
E
Light
VIDEO +
VIDEO–
MONITOR
TV (75 ohm)
PS18
L
Local switch
MAW-B
PS24
MONITOR
TV (75 ohm)
2
Master
MK-2MCD
B1
B2
SUB
PS24PS18
: 24V DC power supply for MAW-B or Relay
locally available.
+
(MK-2HCD)
(MK-DGC 1 )
(MK-DGC 2 )
YELLOW
ORANGE
3
MK-D
2
Light
2
2
BLUE
WHITE
GRAY
GRAY
(MK-2HCD)
NOTE: YELLOW & ORANGE wire provides selective door release control
with RY-3DL adaptor. Works for MK-2MCD only.
NTSC
Contact rating:
0.5A (DC 30V. AC 125V)