Assembly instructions
Change circuit board – motor control Aquatec
®
Beluga
Status: 01.12.06 / Marketing page 3 of 4 V/Allgemein/Montage/Montageanleitungen/Englisch
Beluga/Change circuit board – motor control Beluga
15980 Change circuit board – motor conrol Beluga
3. Loosen the screws of the electronic casing lid and carefully remove the lid and the
gasket.
4. Remove the plugs from the circuit board with the pliers
2x for the battery, 2x for the motor, 1x for the hand control
and remove the circuit board.
E. ASSEMBLY
1. Attach the plugs for battery, motor and hand control to the respective connectors
on the new circuit board.
2. Fit the cable sockets of hand control and motor cable correctly in the respective
grooves.
3. Place the battery in the guiding rail at the back and push the buttons of the hand
control to check proper function of the bathlift.
4. Replace the gasket carefully and close the electronic casing with the lid.
5. Tighten the screws of the lid. Take care not to strip them!