Aquatec Beluga Assembly Instructions

Type
Assembly Instructions
Assembly instructions
Change circuit board – motor control Aquatec
®
Beluga
Status: 01.12.06 / Marketing page 1 of 4 V/Allgemein/Montage/Montageanleitungen/Englisch
Beluga/Change circuit board – motor control Beluga
15980 Change circuit board – motor conrol Beluga
Read the assembly instructions carefully before you start to work!
A. ACCESSORIES
1. Circuit board motor control (order no. 15183)
2. Assembly instructions (4 pages)
B. TOOLS
1. Philips screw-driver
2. Pliers
C. PREPARATION
1. Place the folded Aquatec
®
Beluga on a table.
2. Remove the battery.
D. DISMANTLING
Up to serial no. 900731
1. Release the actuator tube from the spindle catch.
Assembly instructions
Change circuit board – motor control Aquatec
®
Beluga
Status: 01.12.06 / Marketing page 2 of 4 V/Allgemein/Montage/Montageanleitungen/Englisch
Beluga/Change circuit board – motor control Beluga
15980 Change circuit board – motor conrol Beluga
2. Remove the bow from the backrest by pressing its legs and fold up the actuator.
from serial no. 900732
1. Remove the bow from the backrest by tilting and pulling upwards.
2. Release the actuator tube from the spindle catch and fold up the actuator.
Assembly instructions
Change circuit board – motor control Aquatec
®
Beluga
Status: 01.12.06 / Marketing page 3 of 4 V/Allgemein/Montage/Montageanleitungen/Englisch
Beluga/Change circuit board – motor control Beluga
15980 Change circuit board – motor conrol Beluga
3. Loosen the screws of the electronic casing lid and carefully remove the lid and the
gasket.
4. Remove the plugs from the circuit board with the pliers
2x for the battery, 2x for the motor, 1x for the hand control
and remove the circuit board.
E. ASSEMBLY
1. Attach the plugs for battery, motor and hand control to the respective connectors
on the new circuit board.
2. Fit the cable sockets of hand control and motor cable correctly in the respective
grooves.
3. Place the battery in the guiding rail at the back and push the buttons of the hand
control to check proper function of the bathlift.
4. Replace the gasket carefully and close the electronic casing with the lid.
5. Tighten the screws of the lid. Take care not to strip them!
Assembly instructions
Change circuit board – motor control Aquatec
®
Beluga
Status: 01.12.06 / Marketing page 4 of 4 V/Allgemein/Montage/Montageanleitungen/Englisch
Beluga/Change circuit board – motor control Beluga
15980 Change circuit board – motor conrol Beluga
6. Fold the actuator back again. Make sure that the spring plate is in the right position.
7. Attach the bow again to the backrest.
8. Finally check again if the black gasket of the electronic casing is in its correct
position.
arch longitudal to
actuator tube
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Aquatec Beluga Assembly Instructions

Type
Assembly Instructions

Ask a question and I''ll find the answer in the document