2-1. Electronic Malfunction Troubleshooting Chart – C576R
Malfunction Circumstance Points for inspection and testing Components to replace
No start (Alternator) Display is not lit; Exercise on
unit; display shows no reaction
and does not light up.
1. Inspect all cable connections.
2. Inspect alternator power.
3. Inspect drive board CLK6 indicator.
4. Replace drive board.
5. Replace control board.
1. Drive board
2. Control board
No start (Battery) Display does not light when the
exerciser stops exercising.
1. Inspect all cable connections.
2. Inspect the battery fuse.
3. Measure battery voltage. Battery
voltage should be 5.3V or more.
4. If battery voltage is under 8V,
exercise on the unit at 35 RPM per
minute or faster to replenish the
battery.
1. battery fuse on the drive
board
2. battery
No RPM count Start exercising on the unit; the
display shows no reaction;
values on the display do not
change.
1. Inspect speed sensor cable
connection.
2. Inspect the led 1 (CLK) on the drive
board.
3. The distance between speed sensor to
reflective sticker is 5mm..
4. Clean IR detector on the speed
sensor.
5. Replace speed sensor.
6. Replace drive board.
1. Speed sensor
2. Drive board
Polar heart-rate malfunction Polar heart-rate malfunction 1. Replace polar transmitter.
2. Replace polar receive board.
3. Replace control board.
1. Polar transmitter
2. Polar receive board
3.Control board