FAIRCHILD MODEL 63
PNEUMATIC FILTER REGULATOR
Installation, Operation and Maintenance Instructions
2.25
MOUNTING HOLES
BACK SIDE
[57.2]
1.25
MOUNTING
[31.8]
0.32
THRU
2 MOUNTING HOL
ES
8.1
[2.83]
71.9
1.52
3
8.7
7.88
MAX KNOB
[200.3]
2.56
[65]
1.29
[32.6]
1
.91
KNOB
[
48.5]
I
NLET
Æ
OUTLET
Æ
E
XHAUST
Å
1/4 NPT
EXHAUST
1/4 NPT
2.71
[68.9]
0.24
[6]
2 61/64"
[75.1]
7 17/32"
MAX SCREW
[191.1]
0.31
SCREW
[7.9]
8.37
TAMPERPROOF
[212.6]
2.92
74.2
0.75
HEX TAMPERPROOF
[19.1]
Ø[50.8]
Ø2.0
GAGE OPTION
STAINLESS
STEEL TRIM
OPTION
DRAINCOCK
Figure 1. Model 63 Outline Dimensions
Use the two 23/64 thru holes in the Body to mount the
Model 63. Mount the regulator with the Dripwell Drain
Plug at the lowest point for adequate drainage.
Clean all pipelines to remove dirt and scale before
installation.
Apply a minimum amount of pipe compound to the
male threads of the fitting only. Do Not use teflon tape
as a sealant. Start with the third thread back and work
away from the end of the fitting to avoid contaminating
the regulator. Install the regulator in the air line.
The Inlet and Outlet ports are labeled “In” and “Out”.
Tighten all connections securely. Avoid undersized
fittings that limit the flow through the regulator. For
more information, see Figure 1.
INSTALLATION
NOTE: Oil free air must be applied to the regulator. If
an air line lubricator is used, it MUST be
located downstream of the regulator to avoid
interference with performance.
OPERATION
The Model 63 has an Adjustment Screw that controls
output pressure. To increase pressure, turn the
Adjustment Screw clockwise. To decrease pressure,
turn the Adjustment Screw counterclockwise.
For more information, see Figure 1.