FAIRCHILD MODEL 65
PNEUMATIC FILTER REGULATOR
Installation, Operation and Maintenance Instructions
Figure 1. Model 65 Outline Dimensions
Use the two 23/64 thru holes in the Body to mount the
Model 65. Mount the regulator with the Dripwell Drain
Plug at the lowest point for adequate drainage.
Clean all pipelines to remove dirt and scale before
installation.
Apply a minimum amount of pipe compound to the
male threads of the fitting only. Do Not use teflon tape
as a sealant. Start with the third thread back and work
away from the end of the fitting to avoid contaminating
the regulat
or. Install the regulator in the air line.
The Inlet and Outlet ports are labeled “In” and “Out”.
Tighten all connections securely. Avoid undersized
fittings that limit the flow through the regulator. For
more information, see Figure 1.
INSTALLATION
NOTE: Oil free air must be applied to the regulator. If
an air line lubricator is used, it MUST be
located downstream of the regulator to avoid
interference with performance.
OPERATION
The Model 65 has an Adjustment Screw that controls
output pressure. To increase pressure, turn the
Adjustment Screw clockwise. To decrease pressure,
turn the Adjustment Screw counterclockwise.
For more information, see Figure 1.
DRAINCOCK
1.29
32.6
Ø 1.91 KNOB
48.5
3.15
INLET/OUTLET PORT SPACING
80
2.25
MOUNTING HOLES
BACK SIDE
57.2
1.25 MOUNTING
31.8
0.32 THRU
2 MOUNTING HOLES
8.1
2.83
71.9
Ø 1.52
38.7
7.88
MAX KNOB
200.3
INLET/OUTLET
1/4 NPT,
[1/4 BSPT] OR
[1/4 BSPP]
(2) MOUNTING HOLES
1/4-20 UNC-2B X 0.38 DP
[M6-1 X 9.5 DP]
BACK SIDE
EXHAUST
1/4 NPT
[1/4 BSPT]
OUTLET
EXHAUST
INLET
0.31
SCREW
7.9
8.37 TAMPERPROOF
212.6
2.71
68.9
0.71
18
0.24
6
2 61/64"
75.1
7 17/32"
MAX SCREW
191.1
(2) GAGE
PORTS
1/4 NPT
[1/4 BSPT] OR
[1/4 BSPP]
2.92
GAGE PORT SPACING
74.2
0.75
HEX TAMPERPROOF
19.1
GAGE
OPTION
Ø2"
STAINLESS
STEEL TRIM
OPTION