LAMPING
N~E Socket manufacturers have suggested that
socket may fail after 3 to 6 relampings. If this occurs
socket can be replaced by disconnecting male con-
nectors (attached to socket leads) from female con-
nectors (attached to fixture leads) and replacing it
with a new socket procured through Lightoiier (Fig.
G.).
1. Make sure that power is OFF when Iamping or
relamping. Remove LAMP RING from socket cup
pulling straight down.
by
2. Insert LAMP (MR16) between LAMP SPRINGS until
face of lam~ sits firmly on GLASS LAMP GUARD
(Fig. H.). -
3. Attach SOCKET to hi-pin prongs on LAMI?
4. Insert IAMP RING with IAMP and GLASS LAMP
GUARD back into SOCKET CUP
WARNING: 1. LAMP MANUFACTURES RE-
QUIRE THE GLASS IAMP GUARD BE IN
PLACE BEFORE ENERGIZING UIM~ AND THAT
GREAT CARE MUST BE TAKEN THAT LAMP IS
FULLY COOLED BEFORE RELAMPING. AVOID
FINGER MARKS ON INSIDE OF LAMP FOR
THEY MAY CAUSE SHORT IAMP LIFE AND
POSSIBLE BREAKAGE. 2. USE ONLY REFLEC-
10R TRIMS PROVIDED BY LIGHIOLIER INC.
USE OF OTHER MANUFACTURER’S REFLEC-
TOR TRIMS VOIDS THE UNDERWRITERS
LABORATORIES LISTING AND COULD CON-
STITUTE A FIRE HAZARD.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Make sure power is off.
Remove REFLECTOR TRIM from ceiling.
Loosen THUMB SCREWS and lift
TRANSFORMER off bracket.
Remove J-BOX COVER by releasing spring.
Unsplice all wiring in J-BOX.
Remove primary leads from clips attached to side
of housing.
Cut secondary (red) leads 6“ to 8“ from
transformer and discard faulty transformer.
Remove TRANSFORMER BRACKET by removing
screw and nut.
Re-assembie new transformer to TRANSFORMER
BRACKET splice secondary (red) leads to socket
leads. Slide down transformer onto bracket and
tighten THUMB SCREWS, attach primary leads
under clips on side of housing.
Rewire fixture:
a Splice black transformer lead to one of black
thermal protector leads.
b. Replace J-BOX COVER.
c. Install REFLECTOR TRIM.
d. Wire to supply leads.
0191
Page 2 of 2
INSULATING SLEEVING
1,
MALE CONNECTORS
/ (Attached to Socket Wires)
/
<
FEMALE CONNECTORS
(Attached to Fixture Wires)
MR16 SOCKET
L
FIG. G
NOTE: 1.LOW VOLTAGE FIXTURES should be
dimmed only with special dimmers intended
specifically for that purpose Use Lightolier
Lytemode, Scenlst, Crescendo VA, Neptune VA,
Precision VA, Easyset VA, Sunrise VA, Radiant VA
or equivalent products by others or variable
autotransformers or electronic dimmers intended
for use with low voltage flxture& 2. Low voltage
fixtures may produce audible sound when used
with dimmer$ which may be objectlonal in
acoustically critical area=
‘4-SOCKET
4
LAMP –,, /
LAMP SPRING
?“’ I
1
GLASS LAMP
‘<“
GUARD
11
LAMP RING
FIG. H
THERMAL CUTOUT
~ ‘5%” /[
7
P
I
~---%z---J ~RANsFoRMER
JUNCTION BOX
MAX, OF (6) #12AWG
/
PRIMARY 120V.60Hz
BRANCH CIRCUIT CONDUCTORS
SECONDARY 11.OV.‘oW. LOAD
SUITABLE FOR AT LEAST 90“C
BRACKET
—
PERMITTED IN JUNCTION BOX.