Silicone
Sealant
10701
10703
Tools and Supplies
You will need the following to install your new faucet:
Pipe
Tape
Adjustable
Wrench
Phillips
Screwdriver
Single Control
Kitchen Faucet
With Pull Down Spray
Before You Begin
Check to make sure you have the following:
Shut off main water supply before installation.
Faucet Installation
3 Remove base insert from
base.
4 Remove quick connector
from hose.
5 Insert hose through small hole of
base.
1 The cover plate is optional, please determine whether you want to install
or not. Place a bead of clear silicone caulk (not included) around the base
of the putty plate. Place the putty plate and the deck plate on the sink.
Rotate the two half-moon locking nuts (a) inward before inserting the base
into the sink. Insert the base into the sink.
6 Insert supply lines and discharge tube one by one through
large hole of base.
7 Align arrow on faucet body with arrow on top mounting
fixture. Attach faucet body to top mounting fixture and turn
counter-clockwise. After installation arrow sticker should be
removed.
2 The word “FRNT” on the top mounting
fixture must face the front of the sink. Turn
the screws with the provided hex wrench
clockwise until the locking nuts secure the
base in place.
Ø1 3/8”~Ø1 1/2”
(Ø35mm~Ø38mm)
1/16”~1”
(1mm~25.4mm)
Ø1 3/8”~Ø1 1/2”
(Ø35mm~Ø38mm)
1/16”~1 1/2”
(1mm~38.1mm)
(a)
(a)
Hot Line
Cold Line
9 Attach the quick connector
over the sprayer hose.
10 Connect water supply
lines and tighten water supply
nuts.
8 Tighten the set screw
with the hex wrench.
12 Attach the weight to
cover the weight locator label
on the spray hose.
11 Remove the protective cap from the outlet port prior to pushing the hose
adapter onto the same port, you will hear a "click" sound once they are joined.
Faucet Installation
13 After installing faucet, remove spray head
and turn on water to remove any left over debris.
Re-assemble spray head.
Protective Cap
Locate here
Red Line
Blue Line
Blue Line
Cold
Red Line
Hot
1 Screw & Plug A66D558
2 Metal Handle A069456
3 Handle Trim Cap A103016
4 Locking Nut A104207
5 Ceramic Disc Cartridge A507348N
6 Pattern Clip A012357
7 Hose Guide A126048GR
8 Spray Head A523178W-54
9 Screw A008003
10 Hose Adaptor Assembly A663123N
11 Spray Hose A515111W
12 Weight A504713
13 Cover Plate Assembly A667003
14 Aerator Wrench A031237GR
15 Hex Wrench (H 2.5 * 11 mm L * 53mm L) A031217
16 Hex Wrench (H 2.5 * 19 mm L * 53 mm L) A031011NI
17 Top Mounting fixture A504027
Keep this manual for ordering replacement parts.
Replacement Parts
Minor problems often can be fixed without a plumber. Before doing any work on the faucet, shut off water supply and
close stopper or drain to avoid losing small parts.
noituloSesuaCmelborP
Troubleshooting Guide
Locking nut has come loose. O-ring
on cartridge is dirty or damaged.
Metal weight is not installed in the
appropriate position.
Hose and spray head connection
may be loose.
Tighten the locking nut. Clean or
replace O-ring.
Reinstall metal weight.
Tighten the connection between the
spray head and hose.
Leaks underneath handle.
Hose does not retract.
There are leaks from the hose
underneath the deck.
12.
1.
2.
9.
8.
6.
7.
10.
13.
15.
14.
4.
5.
3.
16.
17.
11.
/